User manual SEKONIC ZOOM MASTER L-508

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SEKONIC ZOOM MASTER L-508. We hope that this SEKONIC ZOOM MASTER L-508 user guide will be useful to you.

Lastmanuals help download the user guide SEKONIC ZOOM MASTER L-508.


Mode d'emploi SEKONIC ZOOM MASTER L-508
Download
Manual abstract: user guide SEKONIC ZOOM MASTER L-508

Detailed instructions for use are in the User's Guide.

[. . . ] SEKONIC Zoom Master L-508 Operating Manual Congratulations on your purchase of a Sekonic Zoom Master L-508 Exposure Meter. The Zoom Master L-508 is the latest addition to the extensive line of Sekonic Exposure Meters which have been market leaders for over four decades. It was designed to be the ultimate meter, a do-all instrument for the most demanding pros. It is the first zoom spot meter on the market. Nine camera-quality lens elements are required to accomplish its 1° to 4° zoom range. [. . . ] The following Cine Speeds will display: 2, 3, 4, 6, 8, 12, 16, 18, 24, 25, 30, 32, 36, 40, 48, 60, 64, 72, 96, 120, 128, 150, 200, 240, 256, 300 and 360 FPS. 2. · The shutter opening angle that these speeds are based on, is 180 degrees. For other angles make the following ISO film speed corrections. * Example of correction value -1/3: Decrease ISO film speed by 1/3 stop, example: ISO 100 -1/3 stop = ISO 80 +1/3: Increase ISO film speed by 1/3 stop, example: ISO 100 +1/3 stop = ISO 125 4. Press the Measuring button 19 to make a measurement. Release the Measuring button to complete the measurement. The measured value (f stop value) will be displayed. While pressing the measuring button, the meter measures continuously until it is released. Reference: ·"E. u" (Exposure under) or "E. o" (Exposure over) appears when the combination of shutter speed and aperture is not possible for the measured light level. Changing the shutter speed and or aperture with the Set/change dial will allow you to find a combination that is possible. If the "E. u" or "E. o" readout blinks, this indicates that the light level is beyond the measurement range of the light meter. -11- -12- 5. Measuring flash light This method of measurement can be done in the following modes; with cord, without cord, multiple flash with cord, and multiple flash without cord. The measured value displayed is the sum of the flash portion and the ambient light portion. 2-1 Cord Flash mode The most positive method to assure proper synchronization and measurement of flash units. Connect the meter with the flash with a synchronization cord. Be sure to replace Synchro terminal cap after your measurement. Connect the flash synchro cord to the Synchro terminal 8 on the exposure meter. 5. Measurement CAUTION: · There is danger of electric shock if the meter is handled with wet hands, during rain, in areas splashed by water or where there is a lot of moisture, if you use cord synchronized flash. · Under such conditions, it is recommended that you use the meter in the flash cordless mode, and keep the Synchro terminal cap in place. NOTE: · The electronic fire unit may fire when you connect the Synchro cord or operate the POWER Switch. · For flash units with extremely low electric trigger voltage, the flash may not fire. In this case, make measurements in flash mode without cord (see page 15). Reference: · The shutter speed can be set in single or half steps from 1 second to 1/1000 of a second. After 1/1000 sec, the meter can be set at the following intermediate speeds: 1/ 75, 1 /80, 1 /90, 1 /100, 1 /200, or 1 /400. · If the film speed is changed after the measurement is taken, the new converted measured value (f stop value) will be displayed. [. . . ] Accessories Mini Light Receptor (Sold separately) · Incident light receiving unit with a compact 12mm diameter light receiving surface. · For measuring narrow areas used for photographing small subjects or copy work. · Type · Light receiving method Incident light Reflected light · Light Receptors · Metering modes Ambient light Booster (Sold separately) · For light measuring on camera ground glass, focusing screens, SLR eyepieces, microscope eyepiece. · When the Booster is used without any accessory attachments, it can measure reflected light over approximately a 60 degree angle of field. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEKONIC ZOOM MASTER L-508

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SEKONIC ZOOM MASTER L-508 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag