User manual SENNHEISER SKM 500-965 G3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SENNHEISER SKM 500-965 G3. We hope that this SENNHEISER SKM 500-965 G3 user guide will be useful to you.

Lastmanuals help download the user guide SENNHEISER SKM 500-965 G3.


Mode d'emploi SENNHEISER SKM 500-965 G3
Download

You may also download the following manuals related to this product:

   SENNHEISER SKM 500-965 G3 PRODUCT SHEET (352 ko)
   SENNHEISER SKM 500-965 G3 FREQUENCY SHEET (592 ko)
   SENNHEISER SKM 500-965 G3 FREQUENCY SHEETS (633 ko)

Manual abstract: user guide SENNHEISER SKM 500-965 G3

Detailed instructions for use are in the User's Guide.

[. . . ] SKM 500 Instruction manual Contents Contents Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The SKM 500 G3 radio microphone family . . . . . . . . . . . . . . . . . . . . . . . . . 3 The frequency bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Areas of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Move the multi-function switch to adjust the input sensitivity. Press the multi-function switch to store the setting. Canceling an entry ON/OFF Press the ON/OFF button to cancel the entry. The current standard display appears on the display panel. To subsequently return to the last edited menu item: Press the multi-function switch repeatedly until the last edited menu item appears. 18 Using the operating menu Exiting a menu item Change to the "Exit" menu item. Menu Exit Confirm your selection. You return to the next higher menu level. To directly return to the current standard display: ON/OFF Press the ON/OFF button. 19 Adjusting settings via the operating menu Adjusting settings via the operating menu Make use of the possibility to adjust settings via the operating menu of your receiver and to transfer these settings to the radio microphone. For more information, refer to the instruction manual of the receiver. The relevant information is marked with the sync icon. The main menu "Menu" Adjusting the input sensitivity ­ "Sensitivity" Menu Sensitivity ­12 dB Call up "Sensitivity" Sensitivity ­12 dB Select the desired setting Sensitivity ­36 dB Store the setting "Stored" Adjustment range: 0 to -48 dB, adjustable in steps of 6 dB The audio level display "AF" always indicates the audio level, even if the radio microphone is muted, e. g. allowing you to check the adjusted sensitivity before live operation. B. Ch: 20. 30 542. 625 MHz AF P MUTE Input sensitivity is adjusted . . . too high Close talking distances, speakers with loud voices or loud music passages cause overmodulation in the transmission link. The audio level display "AF" shows full deflection for the duration of the overmodulation. The audio level display "AF" shows full deflection only during the loudest passages. The transmission link is undermodulated. This results in a signal with high background noise. . . . too low 20 Adjusting settings via the operating menu The following figures are a guide to the best settings: Transmission situation Loud music/vocals Presentations Interviews Sensitivity setting -48 to -18 dB -18 to -12 dB -12 to 0 dB Selecting the frequency bank and the channel manually ­ "Frequency Preset" Menu Frequency Preset B. Ch: 1. 1 Call up "Frequency Preset" Frequency Preset B. Ch: 1. 1 542. 625 MHz Select the frequency bank and confirm Frequency B. Ch: 20. 1 533. 875 MHz Select the channel; store the setting "Stored" When you are in the "Frequency Preset" menu item, the RF signal is deactivated. Overview of the frequency banks and channels: Frequency bank "1" to "20" Channels Type up to 32 per System bank: frequency frequencies are factorybank preset "U1" to "U6" up to 32 per User bank: frequency frequencies are freely bank selectable When setting up multi-channel systems, please observe the following: Only the factory-preset frequencies within one frequency bank are intermodulation-free (see page 26). Radio microphone and receiver of a transmission link have to be set to the same frequency. It is vital to observe the notes on frequency selection on page 26. Entering a name ­ "Name" Menu Name Lichael Name Lichael Enter a character and confirm Name Michael Enter a character; store the setting Call up "Name" "Stored" Via the "Name" menu, you can enter a freely selectable name (e. g. [. . . ] 450 g Sennheiser HDX 80­18, 000 Hz 115 dBA 0. 9 % 48 dB, adjustable in 6-dB steps 42 MHz ± 24 kHz/± 48 kHz ±15 ppm typ. 30 mW (Standard) can be switched off Transmission frequencies 31 Specifications In compliance with Europe EMC Radio Safety EN 301489-1/-9 EN 300422-1/-2 EN 60065 EN 62311 (SAR) Approved by Canada Industry Canada RSS 123 IC: 2099A-G3SKMEM limited to 806 MHz FCC-Part 74 FCC-ID: DMO G3SKMEM limited to 608 MHz USA Microphone heads MMD 935-1 MMD 945-1 MMK 965-1 Microphone type dynamic dynamic externally polarized dual diaphragm condenser microphone 5. 7 mV/Pa / 1. 8 mV/Pa cardioid / supercardioid, switchable 144 dB SPL / 154 dB SPL Sensitivity Pick-up pattern 2. 5 mV/Pa cardioid 1. 8 mV/Pa supercardioid Max. SPL 154 dB SPL 154 dB SPL Polar diagrams and frequency response curves of the microphone heads Polar diagram MMD 935-1 30° 0° 0 5 10 60° 15 20 25 90° dB 90° 90° Polar diagram MMD 945-1 30° 0° 0 5 10 30° 30° 60° 60° 15 20 25 dB 60° 90° 120° 120° 120° 120° 125 Hz 250 Hz 500 Hz 1000 Hz 150° 180° 150° 2000 Hz 4000 Hz 8000 Hz 16000 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 150° 180° 150° 2000 Hz 4000 Hz 8000 Hz 16000 Hz 32 Specifications Polar diagram MMK 965-1 (cardioid) Polar diagram MMK 965-1 (super-cardioid) Frequency response curve MMD 935-1 dBV -30 -40 -50 -60 -70 -80 50 100 200 500 1. 000 1k 2k 5k 10. 000 10k 20k Hz Frequency response curve MMD 945-1 dBV -30 -40 -50 -60 -70 -80 50 100 200 500 1. 000 1k 2k 5k 10. 000 10k 20k Hz Frequency response curve MMK 965-1 (cardioid) -30 -40 -50 -60 -70 -80 50 100 200 500 1k 2k 5k 10k 20k dBV Hz PAD 0° 1 m Frequency response curve MMK 965-1 (super-cardioid) -30 -40 -50 -60 -70 -80 50 100 200 500 1k 2k 5k 10k 20k dBV Hz PAD 0° 1 m 33 Manufacturer Declarations Manufacturer Declarations Warranty Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER SKM 500-965 G3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER SKM 500-965 G3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag