[. . . ] All horizontal piperuns should have a minimum fall of 1% (10mm in every metre) If pumping vertically always put the vertical before the horizontal at the start of the piperun. 7 INSTALLATION 7b CONNECTION TO LID INLET (SANIVITE®, SANISPEED® and SANIPUMP 2®) To connect to the lid inlet, cut off the sealed cap with a hack saw and connect using a rubber connector provided. 7c CONNECTION OF BATHROOM APPLIANCES (SANIVITE®, SANISPEED® and SANIPUMP 2®) To connect a shower, ensure that the trap exit is 15 cm above floor level. Although not obligatory, a lid connection may be used to run an external air vent. [. . . ] Warning : Prepare an access trap to the unit of at least L-400mm and H- 145mm (the access trap should be built so that tool is required to open it). The Sanishower/Sanipump 1 should always be accessible for possible maintenance. Stanley knife) to remove the cap from the optional inlet (see picture 7c bis). Make sure the hole is not cut at an angle, and that the edges are deburred. Warning : Make sure that this operation is carried out precisely, otherwise the joint will not be watertight. € The rubber connector C can be used for 40 mm or 32 mm waste pipe. If fitting 32 mm waste, cut off the end of connector C (see picture 7c bis). Push the neck of connecto C into the hole. It is a grip fit, which is why the hole must be cut accuratly. Secure the waste pipe to C with clip B . Warning: Ensure the electricity is turned OFF at the main switch board before wiring to connector. All work on cable and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. SANISHOWER® and SANIPUMP 1® : Connect the wires in accordance with their colour coding : live = brown neutral = blue earth = yellow/green 8 STANDARD • The unit conforms with EN 12050-2 effluent lifting station and the European directives and standards concerning electrical safety and electromagnetic compatibility. 9 CARE AND USE SANIVITE®, SANISPEED® and SANIPUMP 2® are designed to handle the waste evacuation from a bath domestic kitchen sink, dishwasher and washing machine - all working at the same time if required. Its powerful pump will deal with every day normal usage. Sanispeed will take the above at a heavier duty rate of usage. SANISHOWER®/SANIPUMP 1® is designed to take the waste from a shower and handbasin. Warning : Do not dispose of solvents, paints (do not wash paint brushes in sink), caustic, acid or other chemicals into these products. Depending on usage, the SANIVITE®, SANISPEED® and SANIPUMP 2® may need to be cleaned from time to time. Heavy usage can result in a build up of fat and grease. The SANIVITE® unit will pump away water as hot as 60°C for 5 minutes, SANISPEED® and SANIPUMP 2® pump 75°C for 5 minutes (i. To clear the hottest waste water from a washing machine). [. . . ] This device limited phy experience given the n of a person sure they d 1 DISMANTLING 0 Disconnect from the power supply before attempting any work on the unit. The unit does not require any specific maintenance. In case of a service requirement, please call own Saniflo service engineer, especially for any electrical work. Dette apparat er ikke beregnet til at blive brugt af personer (herunder børn) hvis fysiske, sensoriske eller mentale evner er svækkede eller personer blottet for erfaring eller kendskab, med mindre de er under opsyn eller har modtaget instruktioner om brugen af apparatet af en person, der er ansvarlig for deres sikkerhed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SFA SANIPUMP 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SFA SANIPUMP 2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag