User manual SHARP AF-S60EX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AF-S60EX. We hope that this SHARP AF-S60EX user guide will be useful to you.

Lastmanuals help download the user guide SHARP AF-S60EX.


Mode d'emploi SHARP AF-S60EX
Download
Manual abstract: user guide SHARP AF-S60EX

Detailed instructions for use are in the User's Guide.

[. . . ] · SUGGESTED TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . · INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 5 5 5 PRECAUTIONS · CAUTION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . · GROUNDING INSTRUCTIONS . . . . . . . . . . . [. . . ] · Push the AC power plug securely into the receptacle and make sure it is not loose. · Use power circuit with a proper voltage rating. Use a three-pronged grounded electrical outlet rated 125V, 60Hz, 15 amp or more, AC only as shown on right. Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire. · Always use a fuse with the proper amp rating. · Use of extension cords of any kind is not recommended. Two-Pole, 3-wire Grounding Receptacle 15 Amps. 125V. Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse. If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding type appliance extension cord rated 125 Volts, 15 amp or more. · Ventilate the room periodically during use, especially if using gas appliances. GROUNDING INSTRUCTIONS WARNING: Improper use of the grounding plug can result in the risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug. If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. This will occur within a 20 min time span. ) During cooling operation F hr 1 ENERGY SAVER POWER ON/OFF Touch ENERGY SAVER pad. · ENERGY SAVER indicator will light. SELECTOR TEMP COOL / FAN TIMER ON/OFF 2 To cancel, touch ENERGY SAVER pad again. · ENERGY SAVER indicator will go off. ENERGY SAVER pad ENERGY SAVER indicator NOTE: ENERGY SAVER cannot be set during fan only (HIGH FAN, MED FAN, LOW FAN) operation. TO CHANGE AIR FLOW DIRECTION Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room. Horizontal louvers Adjusts UP/DOWN air flow Vertical louvers Adjusts LEFT/RIGHT air flow EXHAUST If air in your room is stale, set the EXHAUST lever to the OPEN position. This will exhaust stale air to the outside. The EXHAUST lever should normally be kept in the CLOSED position during cooling for maximum efficiency. EXHAUST Lever CLOSED OPEN 13 HOW TO OPERATE ON TIMER OPERATION · This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. · The unit will start automatically according to your setting. When the unit is not operating SELECTOR indicator 1 ENERGY SAVER POWER ON/OFF Touch the TIMER ON/OFF pad to set the delayed start time. · The time setting will change as you touch the pad. The display will change as follows; Preset(0. 5h) F hr SELECTOR TEMP COOL / FAN TIMER ON/OFF Previous setting 0. 5h 1. 0h 1. 5h 12h 10h 11h CL(cancel) TIMER ON/OFF pad TIMER indicator (If you wish to start the operation 6 hours and 30 minutes later, set the delay time as shown above. ) · The timer will be set, 5 seconds after the TIMER ON/OFF pad is touched for the last time. · SELECTOR indicator and TIMER indicator will light. · The time display will count down the remaining time. · The unit will start when the set time expires. The temperature setting will be displayed. TO CANCEL THE TIMER SETTING Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display. NOTES FOR TIMER SETTING AND OPERATION: · After setting the TIMER, change the temperature and fan speed settings as shown on pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display. [. . . ] Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage to the unit, do not use hot water (120°F(50°C) or more) when cleaning. OILING OF THE COMPRESSOR AND FAN MOTOR IS UNNECESSARY The compressor is permanently lubricated and is hermetically sealed. The fan motor is lifetime sealed and does not require oiling. 18 BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL · Is the unit plugged in or is the plug loose?· Is the fuse blown or the circuit breaker tripped? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-S60EX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-S60EX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag