User manual SHARP AN-LS1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AN-LS1. We hope that this SHARP AN-LS1 user guide will be useful to you.

Lastmanuals help download the user guide SHARP AN-LS1.


Mode d'emploi SHARP AN-LS1
Download

You may also download the following manuals related to this product:

   SHARP AN-LS1 OPERATION MANUAL (1026 ko)

Manual abstract: user guide SHARP AN-LS1

Detailed instructions for use are in the User's Guide.

[. . . ] Introduction Ethernet to RS-232C Network Converter Connections MODEL AN-LS1 OPERATION MANUAL Setup Using the Software · Please read this operation manual carefully to ensure correct use of the Ethernet to RS232C Network Converter. · Please read this operation manual together with the "IMPORTANT INFORMATION" leaflet. · Prior to installation of this product, carry out the appropriate network settings. Appendix Outstanding Features AN-LS1 is a network converter for converting TCP/IP protocol on Ethernet to serial (RS-232C). I AN-LS1 enables Sharp projectors with RS-232C terminals to be controlled via Ethernet. I Since AN-LS1 is provided with an RS-232C terminal as well as an Ethernet terminal, control using a commercially available locally installed controller is possible as well as via a network. Computer Control via network Ethernet LAN Projector Local control Controller In this operation manual, the illustration and the screen display are simplified for explanation, and may differ slightly from actual display. Accessories Supplied Accessories I AC Adaptor I CD-ROM (Driver software and PDF operation manual) I IMPORTANT INFORMATION (Leaflet) I USA/Canada warranty card I International Software license (Paper) · Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. [. . . ] Display set numerical value. 22 Carrying out Network Ping Test (ADVANCED[5]Network Ping Test) It is possible to confirm that a network connection between AN-LS1 and a computer etc. is working normally. advanced>5 Ping dest IP addr :192. 168. 150. 1 Please Enter :192. 168. 150. 152 (change) --> 192. 168. 150. 152 32 bytes from 192. 168. 150. 152: icmp_seq = 1, time = 0 ms 32 bytes from 192. 168. 150. 152: icmp_seq = 2, time = 0 ms 32 bytes from 192. 168. 150. 152: icmp_seq = 3, time = 0 ms 32 bytes from 192. 168. 150. 152: icmp_seq = 4, time = 0 ms Enter "5" and press the return key. Enter IP address of device to be tested and press the return key. Display test result. · If the return key is pressed without entering an IP address, the Ping destination IP address used before is entered. · If there is a fault with the connection, "Error: No answer" is displayed after a 5 second retry. In this case, please confirm the settings for AN-LS1 and the computer, and contact your network administrator. Setting of Accept IP Address (ADVANCED[6]Accept IP Addr(1) - [8]Accept IP Addr(3)) It is possible to improve security of AN-LS1 by allowing connection from only a prescribed IP address. It is possible to set up to three IP addresses allowing connection to AN-LS1. Setup advanced>6 Accept IP Addr(1) : 0. 0. 0. 0 Please Enter : 192. 168. 150. 152 (change) --> 192. 168. 150. 152 Enter "6", "7" or "8" and press the return key. Enter numerical value and press the return key. Display set numerical value. · To invalidate the Accept IP Address being currently set, enter "0. 0. 0. 0". · If there is one or more Accept IP Addr being set, no connections are allowed from IP addresses that are not yet set. They can be cancelled using [9]Accept All IP Addr. Accepting All IP Addresses (ADVANCED[9]Accept All IP Addr) Removes IP addresses set with "Accept IP Addr". advanced>9 Accept All IP Addresses(y/n)?y Enter "9" and press the return key. Enter "y" and press the return key. · At the point in time where "y" was entered, the numerical values for Accept IP Addr(1)-(3) are reset to "0. 0. 0. 0". · If "n" is entered, settings are not altered. 23 Setting of Port for Search (ADVANCED[0]Port for Search) Sets the port number used when Sharp COM Redirection Software searches for AN-LS1. advanced>0 Please Enter Port Number for Search from Computer. Valid range : 1025 to 65535 Port for Search : 5006 Please Enter : 5004 (change) --> 5004 Enter "0" and press the return key. Enter numerical value and press the return key. Display set numerical value. Return to Default Settings (ADVANCED[!]Restore Default Setting) Returns all setting values that can be set using the menu to the default state. Same operation as turning on the power while holding down the INIT. (Initialize) button on the unit. advanced>!y -- User Setting Initialized -- Enter "!" and press the return key. Enter "y" and press the return key. · If this operation is performed while changing the setting for AN-LS1 via Telnet, there may be situations where AN-LS1 cannot be connected depending on the network setting for the computer for control since the set values for IP Address, Subnet Mask, Gateway and etc. are restored to the initial state. Return to Main Menu (ADVANCED[Q]Return to Main Menu) Returns to the main SETUP MENU. advanced>q ---------------- S E T U P M E N U -------------------- [1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Unit Name [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> Enter "q" and press the return key. 24 About Sharp COM Redirection Software Using Sharp COM Redirection Software, it is possible to create a "Virtual COM" port. If general application software outputs data to this Virtual COM port, Sharp COM Redirection Software will transfer the data to AN-LS1 which is on a network. With this system, control for a projector conventionally carried out via a COM port can be carried out via an Ethernet LAN without changing control software. Computer Application software Sharp COM Redirection Software (Virtual COM) COM port (RS-232C) Ethernet port Ethernet LAN AN-LS1 Projector This software supports the following Operating Systems: Windows 98, 98SE, Me, 2000 Professional, XP Home Edition, XP Professional Edition. [. . . ] 19 Password (Sharp COM Redirection Software) . . . . . . . . . . . . . . . . 40 Port for Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Q Quit Unchanged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AN-LS1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AN-LS1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag