User manual SHARP AY-XP9FR-N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP AY-XP9FR-N. We hope that this SHARP AY-XP9FR-N user guide will be useful to you.

Lastmanuals help download the user guide SHARP AY-XP9FR-N.


Mode d'emploi SHARP AY-XP9FR-N
Download

You may also download the following manuals related to this product:

   SHARP AY-XP9FR-N (1113 ko)

Manual abstract: user guide SHARP AY-XP9FR-N

Detailed instructions for use are in the User's Guide.

[. . . ] AY-XP9FR -N AY-XP12FR-N AY-XP12GR-N SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL INDOOR UNIT OUTDOOR UNIT AY- XP9FR-N AE- X9FR-N AY- XP12FR-N AE- X12FR-N AY- XP12GR-N AE- X12GR-N *Plasmacluster is a trademark of SHARP Corporation. A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin!Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. [. . . ] · The remote control can send signals from up to 7 metres away. 6 CAUTION · Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. · Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal. · The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room. · Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them. SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o'clock in the afternoon Clock Display 12-hour mode 24-hour mode PM 5:00 17:00 MODE 1h 1 To set to the 12-hour mode, press the CLOCK button once in the first step. 2 3 1 To set to the 24-hour mode, press the CLOCK button twice in the first step. TIME 2 Press the set theADVANCE or REVERSE button to current time. · Keep the button pressed to advance or reverse the time display quickly. CLEAN FAN SWING SET/C the SET/C button. 3 Press colon (:) blinks to indicate that the · The clock is functioning. NOTE: · The current time cannot be set when the timer is operating. 7 BASIC OPERATION 1 Press the MODE button to select the operation mode. AUTO HEAT COOL DRY 2 2 5 3 DISPLAY Press the ON/OFF button to start operation. · The red OPERATION lamp ( will light. · During SELF CLEAN operation, the indicator panel will display remaining time of the operation. Room and outdoor temperature will not be displayed even if you press the DISPLAY button. 9 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION 1 Press the SWING button remote control once. MODE 1h on the · The vertical adjustment louvres will change its angle continuously. CLEAN FAN SWING SET/C 1 2 again when 2 Press the SWING button louvres are the vertical adjustment at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time. Adjustment range COOL and DRY modes HEAT mode HORIZONTAL AIR FLOW DIRECTION Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction. AY-XP9FR-N/AY-XP12FR-N AY-XP12GR-N CAUTION Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode with the fan speed set to "SOFT ( )" for an extended period of time. Condensation may form on the louvres. 10 PROGRESSIVE AIRFLOW Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvres are set obliquely upward to deliver cool air to the ceiling. Press the button during heating operation. Vertical adjustment louvres are set downward to deliver the warm air down to the floor and warm you. 1 During operation, AIRFLOW button. AM press the PROGRESSIVE . · The remote control will display TO CANCEL Press the PROGRESSIVE AIRFLOW button. NOTES: DISPLAY 1 · The PROGRESSIVE AIRFLOW setting is cancelled when you press FULL POWER button while PROGRESSIVE AIRFLOW is set. · If you want PROGRESSIVE AIRFLOW operation in FULL POWER mode, press PROGRESSIVE AIRFLOW button during FULL POWER operation. FULL POWER OPERATION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. FULL 1 To activate the button POWER operation, press the FULL POWER during operation. · The remote control will display . · The temperature display will go off. [. . . ] COOLING upper limit lower limit upper limit HEATING lower limit 32°C 21°C 27°C ­ 43°C ­10°C 24°C ­20°C · The built-in protective device may prevent the unit from operating when used out of this range. · Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent. WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery. PREHEATING FUNCTION In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit. DE-ICING FUNCTION · When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AY-XP9FR-N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AY-XP9FR-N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag