User manual SHARP EL-501W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP EL-501W. We hope that this SHARP EL-501W user guide will be useful to you.

Lastmanuals help download the user guide SHARP EL-501W.


Mode d'emploi SHARP EL-501W
Download

You may also download the following manuals related to this product:

   SHARP EL-501W OPERATION MANUAL (1278 ko)

Manual abstract: user guide SHARP EL-501W

Detailed instructions for use are in the User's Guide.

[. . . ] ENGLISH DISPLAY · Floating point system Symbol SCIENTIFIC CALCULATOR MODEL EL-501W · Scientific notation system OPERATION MANUAL PRINTED IN CHINA / IMPRIMÉ EN CHINE / IMPRESO EN CHINA 04AGK (TINSE0496THZZ) Mantissa Exponent (During actual use not all symbols are displayed at the same time. ) If the value of mantissa does not fit within the range ±0. 000000001 ­ ±9999999999, the display changes to scientific notation. The display mode can be changed according to the purpose of the calculation. 2ndF HYP : Appears when @ is pressed, indicating that the functions shown in orange are enabled. : Indicates that h has been pressed and the hyperbolic functions are enabled. [. . . ] To clear the setting of decimal places, press @ i . . 100000÷3= [Floating point] [TAB set to 2] [Scientific notation] [Floating point] Chain Calculations This calculator allows the previous calculation result to be used in the following calculation. The previous calculation result will not be recalled after entering multiple instructions. ª100000/3= @i 2 @i. 33333. 33333 33333. 33 3. 33 04 33333. 33333 Time, Decimal and Sexagesimal Calculations This calculator performs decimal-to-sexagesimal conversion and sexagesimal-to-decimal conversion. In addition, the four basic arithmetic operations and memory calculations can be carried out using the sexagesimal system. Notation for sexagesimal is as follows: · If the value for floating point system does not fit in the following range, the calculator will display the result using scientific notation system: 0. 000000001 | x | 9999999999 Determination of the Angular Unit In this calculator, the following three angular units (degrees, radians, and grads) can be specified. DEG (°) 123. 404080 degree minute Note: When the calculation or conversion result is converted, a residual may occur. second Press G GRAD (g) RAD (rad) Coordinate Conversions · Before performing a calculation, select the angular unit. Y y 0 x X P (x, y) Y P (r, ) r 0 STATISTICAL CALCULATIONS Press @ Æ to select statistics mode. The following statistics can be obtained: x sx x n x x2 Mean of samples (x data) Sample standard deviation (x data) Population standard deviation (x data) Number of samples Sum of samples (x data) Sum of squares of samples (x data) X Rectangular coord. Polar coord. BINARY, OCTAL, DECIMAL, AND HEXADECIMAL OPERATIONS (N-BASE) This calculator can perform the four basic arithmetic operations, calculations with parentheses and memory calculations using binary, octal, decimal, and hexadecimal numbers. When performing calculations in each system, first set the calculator in the desired mode before entering numbers. It can also perform conversions between numbers expressed in binary, octal, decimal and hexadecimal systems. Conversion to each system is performed by the following keys: Ï ê : Converts to the binary system. Ï î : Converts to the octal system. Ï ì : Converts to the hexadecimal system. Ï í : Converts to the decimal system. "BIN", "OCT", and "HEX" disappear from the display. Conversion is performed on the displayed value when these keys are pressed. Note: In this calculator, the hexadecimal numbers A ­ F are entered by pressing E, Ñ, /, ´, I, and l, and displayed as follows: F A B C D E Data Entry and Correction Entered data are kept in memory until @ Æ or F are pressed. Before entering new data, clear the memory contents. [Data Entry] Data k Data * frequency k (To enter multiples of the same data) [Data Correction] Correction prior to pressing k: Delete incorrect data with ª. Correction after pressing k: Reenter the data to be corrected and press @ J. · The number displayed after pressing k or @ J during data entry or correction is the number of samples (n). Statistical Calculation Formulas In the statistical calculation formulas, an error will occur when: · the absolute value of the intermediate result or calculation result is equal to or greater than 1 × 10100. · an attempt is made to take the square root of a negative number. A å, B , C ç, D , E é, F In the binary, octal, and hexadecimal systems, fractional parts cannot be entered. When a decimal number having a fractional part is converted into a binary, octal, or hexadecimal number, the fractional part will be truncated. Likewise, when the result of a binary, octal, or hexadecimal calculation includes a fractional part, the fractional part will be truncated. [. . . ] (12­6i) + (7+15i) 12 a 6 ±b+ 7 a 15 b 8. 6×(7­9i) × (­5+8i) = 6 a* 7 a 9 ±b* 222. 5 ±a 8 b= b 606. ···· DATA 30 40 40 50 DATA 30 45 45 45 60 @Æ@Æ 30 k 40 * 2 k 50 k 50 @J 40 * 2 @J STAT 0. 5. 16×(sin30°+icos30°) 16 a* 30 sa 30 ub = (sin60°+icos60°) / 60 sa 60 ub 13. 85640646 = b 8. y A r1 1 2 x = x n sx = x2 ­ nx2 n­1 r r2 B x 8 a 70 b@} + 12 a 25 b@} 18. 5408873 =@{ [r] b [] 42. 76427608 x = x2 ­ nx2 n x = x1 + x2 + ··· + xn x2 = x12 + x22 + ··· + xn2 r1 = 8, 1 = 70° r2 = 12, 2 = 25° r = ?, = ?° (1 + i) r = ?, = ?° 1 a 1 b= @{ [r] b [] 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP EL-501W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP EL-501W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag