User manual SHARP IG-BC2J-B DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP IG-BC2J-B. We hope that this SHARP IG-BC2J-B user guide will be useful to you.

Lastmanuals help download the user guide SHARP IG-BC2J-B.


Mode d'emploi SHARP IG-BC2J-B
Download
Manual abstract: user guide SHARP IG-BC2J-BDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] E-6 HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT . . . E-7 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-8 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-8 · While IG-BC2J-B can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. [. . . ] The information provided in this manual is subject to change without notice. E- ENGLISH IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire, or injury : · Read all instructions before using the unit. · Use only a 220-240 volt outlet. · DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is loosened. · Periodically remove dust from the plug. · DO NOT insert fingers or foreign objects into the air intake or air outlet. · Always hold the plug and never pull on the cord when removing the power plug. Electrical shock and/or fire from a short circuit may result. · DO NOT remove the plug when your hands are wet. · DO NOT use the unit near gas appliances or fireplaces. · If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp Authorized Service Center or similarly qualified person in order to avoid a hazard. · Be cautious when cleaning the unit. 1 month (approx, 720 hours), when operated 24 hours a day. Lighting (orange) Press FILTER RESET Button, it sounds "" and the light is turned off. Detach the filter and remove dust with using a vacuum cleaner. Detach Tab Clean Attach Filter Push the both tabs toward arrow. Push and set the another side of filter tab toward arrow. <FILTER RESET Button> After cleaning, press FILTER RESET Button for 3 seconds. Even if the FILTER CLEAN LIGHT is off, press the FILTER RESET Button for 3 seconds after cleaning. E-5 ENGLISH PLASMACLUSTER ION GENERATING UNIT REPLACEMENT In order to release Plasmacluster Ion stably, periodical replacement of Plasmacluster Ion Generating Unit is necessary. The Unit Replacing Light lights up as a reminder for replacement. Elapsed Time Beginning to use. Display Lighting(green) Message Operate normally. Approx. 16, 000 hours) Lighting(orange) The Plasmacluster Ion Generating Unit is soon be replaced. Approx. 17, 500 hours) Flashing(red) Suggest replacing Plasmacluster Ion Generating Unit. Approx. 19, 000 hours) Flashing faster(red) ·Unit stops operation. ·Replace the Plasmacluster Ion Generating Unit. * Usage environment affects the lifetime of the Plasmacluster Ion Generator. The Plasmacluster Ion Generator may stop operating before estimated lifetime. In this case, press Operation button again and restart. If this does not help, replace with a new Plasmacluster Ion Generating Unit. Plasmacluster Ion Generating Unit for Replacement <For Disposal> Please dispose the used Plasmacluster Ion Generating Unit according to any local laws and regulations. [. . . ] *2 Ion count per cm3 blown into air at around the center of the room ( at a height of approx. . 2m from the floor) during operation at each airstream setting when the main unit is placed near the wall. · The number of ions will vary according to the room conditions and operation mode. Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0. 8W of standby power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP IG-BC2J-B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP IG-BC2J-B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag