User manual SHARP IG-CL15U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP IG-CL15U. We hope that this SHARP IG-CL15U user guide will be useful to you.

Lastmanuals help download the user guide SHARP IG-CL15U.


Mode d'emploi SHARP IG-CL15U
Download
Manual abstract: user guide SHARP IG-CL15U

Detailed instructions for use are in the User's Guide.

[. . . ] E-2 • While IG-CL5U can inactivate suspended viruses and other contaminants, it cannot create a completely sterilized environment. SHARP does not guarantee its ability to prevent microbial infection. €¢ To enable stable emission of high-density Plasmacluster ions, the Plasmacluster Ion Generating Unit mounted in IG-CL5U will need to be replaced periodically*. * Replacement is required approximately every 2 years (7, 500 hours) when operated 24 hours a day. [. . . ] lIMITED WARRANTY Consumer Electronics Products Congratulations on your purchase!WARRANTY PERIODS: Audio Product Camcorder DVD Product Projector LCD TV Microwave Oven Air Purifier Portable Air Conditioner Plasmacluster Ion Generator Parts & Labour (exceptions noted) 1 year 1 year 1 year 1 year (lamp 90 days) 1 year 1 year (magnetron component-4 additional years) 1 year 1 year 1 year To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact: SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East Mississauga, Ontario L4Z 1W9 BE THE BEST TO For more information on this Warranty, Sharp Extended Warranty Offers, Sharp Canada Products, Accessory Sales, Dealer or Service Locations, please call (905) 568-7140 Visit our Web site: www. 13 8:58:12 AM ENGLISH TH R OU G IMPORTANT SAFETY INSTRUCTIONS Please read instructions carefully before using IG-CL5U. When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electric shock, fire, or injury : • Use only a 20 volt outlet. • The Plasmacluster Ion Generator has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit into the outlet, reverse it. if it still does not fit , contact a qualified electrician or service person. €¢ DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is loosened. • Periodically remove dust from the plug. €¢ DO NOT insert fingers or foreign objects into the air intake or air outlet. €¢ Always hold the plug and never pull on the cord when removing the power plug. Electric shock and/or fire from short circuit may result. €¢ DO NOT remove the plug when your hands are wet. €¢ DO NOT use the unit near gas appliances or fireplaces. €¢ If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp Authorized Service Center or similarly qualified person in order to avoid a hazard. €¢ Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior. €¢ DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom. €¢ Only Sharp Authorized Service Center should service this Plasmacluster Ion Generator. Contact the nearest Service Center for any problems, adjustments, or repairs. [. . . ] FILTER INSTALLATION Push the right side of the filter in order of , and lock each tab securely. ATTENTION The Plasmacluster Ion Generator might not work correctly if filter is not properly attached. Screw 2 1 <For Disposal> Please dispose the used Plasmacluster Ion Generating Unit according to any local laws and regulations. 8m3/min) * The applicable floor area for which an emitted airborne ion density of about 25, 000 ions/cm3 can be measured at a point near the center of the room (at a height of about 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP IG-CL15U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP IG-CL15U will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag