User manual SHARP R10/6R-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP R10/6R-10. We hope that this SHARP R10/6R-10 user guide will be useful to you.

Lastmanuals help download the user guide SHARP R10/6R-10.


Mode d'emploi SHARP R10/6R-10
Download
Manual abstract: user guide SHARP R10/6R-10

Detailed instructions for use are in the User's Guide.

[. . . ] See Figures 1 and 2. 30" Freestanding Range ELECTRIC RANGE WITH MICROWAVE DRAWER RANGE MEASUREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CLEARANCES AND DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IMPORTANT NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 UNPACKING AND EXAMINING YOUR RANGE . . . . . . . . . . . . . . . . . 3 IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 3 ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 ADJUSTABLE BACKSPLASH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 ANTI-TIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 MODEL AND SERIAL NUMBER LOCATION . . . . . . . . . . . . . . . . . . . . 8 CARE, CLEANING AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . 8 1 INSTALLATION MANUAL RANGE MEASUREMENTS 29 7/8" 30" minimum 30" to bottom of cabinet over cooktop 29 5/8" adjustable backsplash width 18" to upper cabinets 42-48" with adjustable backsplash 36±1/8" to cooktop surface 42" drawer open 6" 6 1/8" 6" 6 1/8" Maximum depth of cord, plug and receptacle box 4" to prevent interference with lower oven 36" countertop height 7 3/8" 27" back to front of doors 4" Preferred electrical outlet area 30" opening width Figure 1 45 3/8" oven door open 30" door widths Figure 2 Figure 1 contains many range measurements for reference when planning your kitchen and/or range location. CLEARANCES AND DIMENSIONS · Provide adequate clearances between the range and adjacent combustible surfaces. · Dimensions that are shown in Figure 2 must be used. Given dimensions provide minimum clearance. [. . . ] Terminals on end of wires must be either closed loop or open-end spade lugs with upturned ends. The range connection opening should be 1 3/8-inches. To reduce the risk of tipping the range, it must be secured by properly installed Anti-Tip bracket packed with the range. · This range must be electronically grounded in accordance with local codes, or in their absence, with the National Electrical Code ANSI/NFPA No. · The installation of ranges designed for manufactured (mobile) home installation must conform with Manufactured Home Construction and Safety Standard, title 24CFR, part 3280 [Formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part 280)] or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups), ANSI Z225. 1/NFPA 501A- latest edition, or with local codes in United States. · Make sure the wall coverings and the cabinets around the range can withstand the heat generated by the range. · Before installing the range in an area covered with linoleum or any other synthetic floor covering, make sure 3 INSTALLATION MANUAL 4-wire wall receptacle (14-50R) Risk of fire or electrical shock exists if an incorrect size range cord kit is used or the Installation Manual or strain relief clamp are disregarded. installed range wiring to the terminal block while connecting range. Electrical failure or loss of electrical connection may occur. ELECTRICAL SHOCK HAZARD CAUTION Do not loosen the nuts which secure the factory- Figure 5A 4-wire wall receptacle (14-50R) Figure 5B 3-wire wall receptacle (10-50R) · Electrical ground is required on this range. · Do not connect to the electrical supply until range is permanently grounded. · DISCONNECT POWER TO THE CIRCUIT BREAKER OR FUSE BOX BEFORE MAKING THE ELECTRICAL CONNECTION. See Figure 7. GROUNDING INSTRUCTIONS- ONLY 3-WIRE CONNECTIONS: Before wiring the range, review the suggested power source location drawings in Figure 2. If connecting to a 4-wire electrical system: 1 Follow the manufacturers Installation Instructions supplied with the strain relief clamp and install. 2 Strip insulation away from the ends of the permanent wiring for line 1, line 2 and neutral; also strip ground wire on 4-wire connections. Tighten all 3 or 4-wire leads to the terminal block. Follow wire locations shown in Figure 10. connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed. Note: For 3-wire permanent connection skip steps 3 and 4 and continue with step 5. 3 Disconnect the ground strap. Remove the factory installed ground screw and plate to release the factory installed copper ground strap from frame of the range. Cut and discard the copper strap from the terminal block. KEEP the ground screw, ground plate and go to step 4. 4 Connect the green ground wire lead to the frame of the range using the ground screw and plate as shown in Figure 11. [. . . ] When installed to the wall, make sure that screws completely penetrate dry wall and are secured in wood or metal. When fastening to the floor or wall, be sure that screws do not penetrate electrical wiring or plumbing. 1 LOCATE THE BRACKET - USING THE TEMPLATE Drill a 1/8-inch pilot hole where screws are to be located. If bracket is to be mounted to the wall, drill pilot hole at an approximate 20 degree downward angle. If bracket is to be mounted to masonry or ceramic floors, drill a 5/32-inch pilot hole 1 3/4-inches deep. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP R10/6R-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP R10/6R-10 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag