User manual SHARP TL-M5200/M4600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP TL-M5200/M4600. We hope that this SHARP TL-M5200/M4600 user guide will be useful to you.

Lastmanuals help download the user guide SHARP TL-M5200/M4600.


Mode d'emploi SHARP TL-M5200/M4600
Download

You may also download the following manuals related to this product:

   SHARP TL-M5200/M4600 annexe 1 (5373 ko)

Manual abstract: user guide SHARP TL-M5200/M4600

Detailed instructions for use are in the User's Guide.

[. . . ] LCD MONITOR MODEL TL-M5200 TL-M4600 SETUP MANUAL RS-232C Specifications and Commands . . . . . . . . . . 2 Setting up the Monitor Network Environment . . . . Connecting the Monitor to a Computer . . . . . . . . . . . . Setting an IP Address for the Computer . . . . . . . . . . [. . . ] · Monitor Name can be up to 12 characters. · You can input the characters below : A-Z, 0-9, -, _, (, ), space (When "a-z" are input, they are converted to "A-Z" automatically. ) -19 Controlling the Monitor via LAN Setting Error Items and Destination Addresses to which E-mail is to be Sent when an Error Occurs (Mail ­ Recipient Settings) Setting Error Items and the URL that are to be Displayed when an Error Occurs (Service & Support ­ Access URL) On this screen, you can input e-mail destinations to which error notification (error items) e-mails are sent. Items E-mail Address Description Set addresses to which error notification e-mail is sent. Error Mail Error e-mail is sent on the error (Backlight, items checked in their check Temp. ) boxes. This allows you to confirm that the settings for e-mail transmission are properly set. On this screen, you can make settings of the URL and error items that are to be displayed when the monitor has generated an error. Items Access URL Description Set the URL that is to be displayed when an error occurs. Condition The URL is displayed when an (Backlight, error checked in their check Temp. ) boxes occurs. This allows you to confirm that the URL site is properly displayed. Note · E-mail Address can be up to 64 characters. · You can input the characters below : a-z, A-Z, 0-9, !, #, $, %, &, *, +, -, /, =, ?, ^, {, |, }, ~, _, ', . , @, ` (You can input "@" only one time. ) · For details about error items, refer to the monitor's operation manual. -20 Setting up the Monitor Using RS-232C or Telnet Connect the monitor to a computer using RS-232C or Telnet, and open the SETUP MENU on the computer to carry out various settings for the monitor. When Connecting Using RS-232C 7 Input "setup" and press the "Enter" key. · SETUP MENU will be displayed. 1 2 Launch general purpose terminal emulator. Input settings for the RS-232C port of the terminal emulator as follows. Baud Rate Data Length Parity Bit Stop Bit Flow Control : 9600 bps* : 8 bit : None : 1 bit : None SETUP MENU ---------------------------------SETUP MENU-------------------------------[1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Monitor Name [8]DHCP Client [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> Note · User name and password are not set in the factory default settings. · If the user name or password is entered incorrectly three times, SETUP MENU will be quit. * This is the factory default setting. If the value of Baud Rate for the monitor has been changed, set Baud Rate here according to the changed value on the monitor. 3 4 5 Input "MTS11234" and press the "Enter" key. Input "MTS25678" and press the "Enter" key within 10 seconds. Input the user name and press the "Enter" key. · If a user name has not yet been set, just press the "Enter" key. 6 "Password:" is displayed. Input the password and press the "Enter" key. · If a password has not yet been set, just press the "Enter" key. -21 Setting up the Monitor Using RS-232C or Telnet SETUP MENU When Connecting Using Telnet ---------------------------------SETUP MENU-------------------------------[1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Monitor Name [8]DHCP Client [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> 1 2 3 4 Click "Start" from the Windows® desktop and select "Run". Enter "telnet 192. 168. 150. 2" in the text box that opens up. (If the IP address of the monitor is 192. 168. 150. 2. ) Click the "OK" button. Note · If the IP address has been changed, be sure to enter the new IP address in step 2. · User name and password are not set in the factory default settings. · If the user name or password is entered incorrectly three times in steps 4 or 5, SETUP MENU will be quit. "User Name:" is displayed. Input the user name and press the "Enter" key. · If a user name has not yet been set, just press the "Enter" key. 5 "Password:" is displayed. Input the password and press the "Enter" key. · If a password has not yet been set, just press the "Enter" key. 6 Input "setup" and press the "Enter" key. · SETUP MENU will be displayed. -22 Setting up the Monitor Using RS-232C or Telnet SETUP MENU SETUP MENU (Main Menu) ADVANCED SETUP MENU ADVANCED SETUP MENU ******************** ADVANCED SETUP MENU *********************** [1]Auto Logout Time [2]Data Port [5]Network Ping Test [6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3) [9]Accept All IP Addr [0]Search Port ---------------------------------SETUP MENU-------------------------------[1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Monitor Name [8]DHCP Client [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> [!]Restore Default Setting [Q]Return to Main Menu [1]IP Address IP address settings. (Page 26) [2]Subnet Mask Subnet mask settings. (Page 26) [3]Default Gateway Default gateway settings. (Page 26) [4]User Name (Factory default setting : Not Required) Setting of user name for security protection. [. . . ] · Subnet Mask When the gateway setting for the monitor is "0. 0. 0. 0" (Not Used), or the gateway setting for the monitor and the default gateway setting for the computer are the same: · The subnet masks for the monitor and the computer should be the same. · The IP address parts shown by the subnet mask for the monitor and the computer should be the same. (Example) When the IP address is "192. 168. 150. 2" and the subnet mask is "255. 255. 255. 0" for the monitor, the IP address for the computer should be "192. 168. 150. X" (X=3-254) and the subnet mask should be "255. 255. 255. 0". · Gateway When the gateway setting for the monitor is "0. 0. 0. 0" (Not Used), or the gateway setting for the monitor and the default gateway setting for the computer are the same: · The subnets for the monitor and the computer should be the same. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP TL-M5200/M4600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP TL-M5200/M4600 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag