User manual SHARP XE-A506

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP XE-A506. We hope that this SHARP XE-A506 user guide will be useful to you.

Lastmanuals help download the user guide SHARP XE-A506.


Mode d'emploi SHARP XE-A506
Download

You may also download the following manuals related to this product:

   SHARP XE-A506 QUICK START GUIDE (484 ko)

Manual abstract: user guide SHARP XE-A506

Detailed instructions for use are in the User's Guide.

[. . . ] ELECTRONIC CASH REGISTER CAJA REGISTRADORA ELECTRONICA MODEL MODELO XE-A506 INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES WARNING FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. [. . . ] SICS (Single Item Cash Sale) • If an entry of a department programmed for SICS is made first, the sale will be finalized as a cash sale as soon as the department key is pressed. If the entry is made after entering a department not programmed for SICS, the sale will not be finalized until the A key is pressed. Entry digit limit • Set the number of allowable digits for the maximum entry amount for each department. The limit is effective for operations in the REG mode and can be overridden in the MGR mode. example: Programming department 2 as normal dept. Group 1, commission group 1, taxable 1, SICS, negative department, entry digit limit - 7 digits, and allowing open & preset entry. (ABCDEFGHIJK: 01100011173) Key operation example Print 01100011173 @ ™A Dept. Group Commission group From left, AHJK Tax status Sign(I) Preset unit price To program zero Unit price (max. Key A A *To program departments 21 through 40, press the department shift key. Six digits) d s Print To program another department, start from the beginning without pressing the A key. Key operation example 1000 ¡ A Unit price If a department is not programmed to allow the entry of preset unit prices in functional programming, the department is automatically changed to allow the entry of preset unit prices by this programming entry. 14 9:27 AM Page 38 2 PLU/UPC Programming The cash register can handle PLU codes and UPC codes. PLU (Price Look-Up) codes are used for PLU and sub-department functions: The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered. The sub-department is a kind of “open PLU”, which requires you to enter a price after the PLU code is entered. PLU codes consist of 4-digit numbers and leading zeros can be applied to the PLU codes. UPC codes are read by the barcode scanner. The cash register can read UPC-A (number system character: 0, 2, 3, 4, 5), UPC-E, EAN-8 and EAN-13. The register can read add-on codes (2 digits or 5 digits) added on EAN13 codes except ISBN and ISSN codes. Unit prices for UPC codes must be preset, that is, even if price information is included in a code, the register does not refer to it for sales registration. a maximum of 7000 PLU or UPC codes settings are possible. Each one belongs to a department and acquires the department's parameters (dept. A commission group (0 to 2, 0: No commission is applied) can be assigned to each department for commission for clerks. [. . . ] 6 digits Function A BR (bottle return) Bottle return: 1, Normal: 1 B G (group number) 0 to 9 (0: non group) C CM (commission group numer) 0 to 2 (0: non commission) D-G T4 - T1 (taxable 4 - taxable 1) Taxable: 1, Non-taxable: 0 H SICS (single item cash sale) SICS: 1, Normal: 0 I SIGN Negative dept. 14 9:27 AM Page 82 Programming sheet for PLU/UPCs (Please make copies of this sheet. Enter entry limit amount for sub-departments. Function A CM (commission group number) 0 to 2 (0: non commission) B TYPE (PLU/sub-department selection) 1: PLU, 0: Sub-department For UPCs always set 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP XE-A506

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP XE-A506 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag