User manual SHARP XE-A404

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SHARP XE-A404. We hope that this SHARP XE-A404 user guide will be useful to you.

Lastmanuals help download the user guide SHARP XE-A404.


Mode d'emploi SHARP XE-A404
Download

You may also download the following manuals related to this product:

   SHARP XE-A404 (1658 ko)
   SHARP XE-A404 QUICK START GUIDE (205 ko)

Manual abstract: user guide SHARP XE-A404

Detailed instructions for use are in the User's Guide.

[. . . ] FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user's authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. [. . . ] Items sold using the department keys can later be printed on a report shown as the quantities sold and sales amounts classified by department. The data is useful for making purchasing decisions and other store operations. Departments can be assigned to articles whose prices were set using PLU/UPC function. When using a department key, you must set the parameters to specify the department status, such as positive or negative department. Prices can be assigned directly to department keys for frequently purchased items, which enables you to enter the prices by simply pressing the department keys. *1:To program departments 21 through 40, press the department shift key. To program another department, start from the beginning without pressing the A key. *2:Item: A B C D E F G H I J K Type Group number Commission group number Tax 4 status Tax 3 status Tax 2 status Tax 1 status SICS / Normal Sign Entry digit limit Type of unit price entry 99) 0 SICS 1 Normal* 0 Negative department 1 Positive department* 0 0-7 (default:7) Open and preset 3 Preset only 2 Open only* 1 Inhibit department key 0 Select whether you use a department as normal department or for bottle return. group number · If group setting (0 to 9, 0: non group) is done, items sold using the department keys and the associated PLUs 36 and UPCs can be classified into groups for reporting the sales. A commission group (0 to 2, 0: non commission) can be assigned to each department for commission for clerks. Each commission amount for each clerk is calculated based on a programmed commission rate and later printed on clerk reports. tax status (taxable 1 through 4 / non-taxable) · When any entry of a taxable department is made in a transaction, tax is automatically computed according to the associated tax table or rate. sICS (Single Item Cash Sale) · If an entry of a department programmed for SICS is made first, the sale will be finalized as a cash sale as soon as the department key is pressed. If the entry is made after entering a department not programmed for SICS, the sale will not be finalized until the A key is pressed. entry digit limit · Set the number of allowable digits for the maximum entry amount for each department. Group 1, commission group 1, taxable 1, SICS, negative department, entry digit limit - 7 digits, and allowing open & preset entry. Group Commission group *To program departments 21 through 40, press the department shift key. To program another department, start from the beginning without pressing the A key. Key operation example If a department is not programmed to allow the entry of preset unit prices in functional programming, the department is automatically changed to allow the entry of preset unit prices by this programming entry. The cash register can handle PLU codes and UPC codes. PLU (Price Look-Up) codes are used for PLU and sub-department functions: The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered. The sub-department is a kind of "open PLU", which requires you to enter a price after the PLU code is entered. [. . . ] Use these labels with the department keys. Write department names on the labels and attach them to the department keys by first removing the transparent key covers. Programming sheet for departments (Please make copies of this sheet. 6 digits Function A BR (bottle return) Bottle return: 1, Normal: 1 B G (group number) 0 to 9 (0: non group) C CM (commission group numer) 0 to 2 (0: non commission) D-G T4 - T1 (taxable 4 - taxable 1) Taxable: 1, Non-taxable: 0 H SICS (single item cash sale) SICS: 1, Normal: 0 I SIGN Negative dept. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP XE-A404

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP XE-A404 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag