User manual SILENT KNIGHT 5496

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SILENT KNIGHT 5496. We hope that this SILENT KNIGHT 5496 user guide will be useful to you.

Lastmanuals help download the user guide SILENT KNIGHT 5496.


Mode d'emploi SILENT KNIGHT 5496
Download
Manual abstract: user guide SILENT KNIGHT 5496

Detailed instructions for use are in the User's Guide.

[. . . ] MODEL 5496 Intelligent Power Module Installation and Operations Manual Document 151276 08/12/10 Rev: E1 P/N 151276:E1 ECN: 10-484 Contents Section 1 Overview 1. 1 1. 2 1. 3 1. 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 5496 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Agency Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Use 12V batteries of the same AH rating. It is recommended that you replace batteries every five years. Determine the correct AH rating per your current load calculation (see Table 2-4). Note: If you require the power of back up batteries that are too large for the 5496, you can use the RBB cabinet. The RBB Remote Battery Box, holds batteries up to the 35 AH size. (Refer to P/N 151306 for RBB installation instructions. Wire batteries in series to produce a 24-volt equivalent. Do not parallel batteries to increase the AH rating. To Panel Red Black Battery Jumper (P/N 140694) Shipped With 5496 Supervised Non-Power Limited UL Listed 12V Battery Gell Cell UL Listed 12V Battery Gell Cell Replace batteries every 5 years. Figure 3-2 Battery Connection 3-2 151276 Hardware Installation 3. 3 Connecting the 5496 to the FACP 1. Connect the 5496 to the appropriate SBUS. The 5496 is connected directly to a Silent Knight addressable FACP. Use the on-board dipswitch to assign an ID number to the 5496. (See Section 3. 3. 1) Figure 2-1 shows the location of the dipswitches on the 5496 board. Configure the 5496 module by adding it to the system (through JumpStart or manually). You can also assign a name to the module. These procedures are described in Silent Knight addressable FACP Installation Manuals. Silent Knight Addressable FACP Installation Manuals can be found on Silent Knight's web site at www. silentknight. com. 5496 Board Supervised Power Limited 5820XL (Main SBUS) Figure 3-3 Class B 5496 Connection to FACP 151276 3-3 Model 5496 Intelligent Power Module Installation and Operation Manual 3. 3. 1 Setting the Device ID All SBUS modules in the system must have a unique number (1-31) to identify them to the FACP. Use the DIP switch on the 5496 board to set the module ID number. Figure 2-1 shows the location of the dipswitch on the board. Figure 3-4 shows dipswitch setting and the corresponding module ID numbers. Figure 3-4 Possible Module Addresses 3-4 151276 Hardware Installation 3. 4 Notification Appliance Wiring Note: Not all devices can use the Sync feature. Be sure to check Table A-1 in Appendix A to ensure the device you have chosen will work with this feature. 3. 4. 1 Class A Supervised Wiring Figure 3-5 shows how to wire for Class A output supervision. Use in/out wiring methods for proper supervision. Refer to Section 4 for notification appliances compatible with the 5496. Class A Output Notification Circuits The configuration shown in Figure 3-5 shows two, 3-amp devices wired as Class A circuits. When you are using the outputs as Class A circuits, loop the wiring back to the corresponding circuit pair. [. . . ] Return the Silent Knight product circuit board only. Products that are returned in cabinets will be charged an additional $50 to cover the extra shipping and handling costs over board only returns. Silent Knight has the authority to determine if a product is repairable. Products that are deemed un-repairable will be returned to the customer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SILENT KNIGHT 5496

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SILENT KNIGHT 5496 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag