Manual abstract: user guide SILENT KNIGHT 5824SDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] SILENT KNIGHT ® By Honeywell 5824 Serial/Parallel Interface Gateway Module Installation Instructions The 5824 Serial/Parallel Interface Gateway Module (5824) connects a Silent Knight fire alarm control panel (FACP) directly to a printer to print event history. [. . . ] Remove knockout if running wires through the back of the base, and mount the base using any of the mounting holes provided (Figure 2). Mounting hardware not included. Compatibility The 5824 is compatible with all Silent Knight addressable FACPs and with the 5208 conventional FACP. Mounting The 5824 has a plastic enclosure that is surface mounted. To mount the 5824 enclosure: 1. Remove the 5824 circuit board from the enclosure base by pushing outward on one of the snap retaining tabs at the bottom (as Figure 2: Enclosure Base P/N 151392 5824 Serial/Parallel Interface Gateway Module Installation Instructions 4. Snap the circuit board back in the base so the snap retaining tabs hold it in place. Note: It may be necessary to wire to the circuit board before placing it back in the base. See Wiring to a FACP. Table 2: ID Dip Switch Settings ID Number 0* 1 2 3 4 5 6 7 8 Switches 1 Down Up Down Up Down Up Down Up Down 2 Down Down Up Up Down Down Up Up Down Up = On 3 Down Down Down Down Up Up Up Up Down Down = Off 4 Down Down Down Down Down Down Down Down Up Wiring to a FACP See Table 1 and Figure 3 to terminate the wiring. Table 1: 5824 to FACP Connections 5824 Terminals B A S+ SFACP SBUS Terminals B A + - (or GND) * Zero is not used. Connecting to a Printer Connect the printer cable to the serial or parallel on the 5824 and then connect it to the printer. Printer cable not included. Figure 3: Wiring the 5824 to the FACP Setting DIP Switches Each module on a Silent Knight FACP requires an ID number which is set using the DIP switches on the 5824 circuit board. [. . . ] See the FACP installation manual for specific information on device ID assignments. 7550 Meridian Circle Maple Grove, MN 55369-4927 763-493-6455 or 800-328-0103 Fax: 763-493-6475 http://www. silentknight. com © 2005 Silent Knight PN 151392A 2 P/N 151392 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SILENT KNIGHT 5824S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SILENT KNIGHT 5824S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag