User manual SIMRAD FS20

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIMRAD FS20. We hope that this SIMRAD FS20 user guide will be useful to you.

Lastmanuals help download the user guide SIMRAD FS20.


Mode d'emploi SIMRAD FS20
Download
Manual abstract: user guide SIMRAD FS20

Detailed instructions for use are in the User's Guide.

[. . . ] FS 20/25 OPERATORS MANUAL 901-10037001 Issue 1. 1 June 2002 FS 20/25 Operators Manual List of Contents 901-10037001/1. 1 Page 1 Kongsberg Simrad Mesotech Ltd Products Warranty Policy Effective January 1, 2002 Kongsberg Simrad Mesotech Ltd. Warrants each new product (equipment) to be free of defects caused by faulty materials or poor workmanship for a period of twelve (12) months for underwater equipment and twenty-four (24) months for surface equipment from date of installation by an authorized Kongsberg Group Company, Simrad Distributor, Dealer or Agency. The warranty does not apply to defects caused by, force majeure events or misuse, including water damage to the surface equipment, improper maintenance and installation, including excessive wear and tear for which Kongsberg Simrad mesotech Ltd. Is not responsible. Underwater Equipment: · Warranty for underwater Equipment that is hull mounted such as those mentioned below will be assessed on a case-by case basis but shall generally not be covered by the warranty. 1. [. . . ] Port Coquitlam, BC - Canada 901-10037001/1. 1 Page 4. 18 FS 20/25 Operators Manual FS 20/25 Installation, System Set-Up and Test The "System Configuration" window will pop up. "Click" on "Detect Heads" "Click" on "Apply" next "Click" "OK". From the Operating System window, "Click" on the "RUN" Icon to start the System. In the event that part of the system gets changed out with a new component (i. e. a different TTM, a change in software, etc), you might find that the Sonar Head Confirmation window might appear. It will ask you if you want to reconfigure "Click" on "NO", then go back to the "Header Menu" "Click" on "Configuration" and re-start the system set-up as per outline in Paragraph "4. 4. 3" or "4. 4. 4". Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada FS 20/25 Operators Manual FS 20/25 Installation, System Set-Up and Test 901-10037001/1. 1 Page 4. 19 4. 4. 5 FS 20 or FS 20/25 RUN UP Procedure After you "Click" on the "RUN" Icon, the system will automatically detect and setup the sonar heads attached to the trawl cable. After the system RUN UP is completed, the best way to setup your windows is to "Click" on the Tool Bar "Tile Windows" Icon located to the right end side of the Tool Bar. By clicking on the individual window, you can rearrange, change the size, as you prefer, etc. Refer to the following window From that point on by clicking on the "FS 20", TS 15 Sounder or the FS 25 window you will have control over the selected Sonar. The sonar you have selected will be highlighted by a blue bar across the top. . Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada 901-10037001/1. 1 Page 4. 20 4. 4. 6 Display Settings FS 20/25 Operators Manual FS 20/25 Installation, System Set-Up and Test Position the cursor on the "DISPLAY SETTINGS" Icon, (the one next to the small sonar head located on the TOOL BAR), and CLICK. By selecting the appropriate "KEY", you will able to setup your Colors, Controls Setting and the Head Sensors. By clicking on the appropriate "key" you will be able to change the color i. e. Overlay colors, Pallets styles and threshold, etc. The same operation will apply to the TS15 S sounder, and the FS25 windows Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada FS 20/25 Operators Manual FS 20/25 Installation, System Set-Up and Test 901-10037001/1. 1 Page 4. 21 4. 4. 7 Control Setting By selecting and clicking on the "Control" key on the above window, the following window will pop up. By clicking on the appropriate key, you will be able to setup your control setting, i. e. Note: The "Timer Control" will be turn "ON" automatically when you CLICK on the "S" Icon located on the "Tool Bar". The same operation will apply to the TS 15 S sounder and the FS 25 windows Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada 901-10037001/1. 1 Page 4. 22 4. 4. 8 Head Sensors Setting FS 20/25 Operators Manual FS 20/25 Installation, System Set-Up and Test By selecting and clicking on the "Head Sensors" key on the above window, the following window will pop up. By clicking on the appropriate key, you will be turning the catch sensor ON or OFF. The Depth and temperature can also be changed. Note: The "Heads Sensors" will be turn "ON" automatically when you CLICK on the "S" Icon located on the "Tool Bar". You can turn "ON" or "OFF" the catch Sensors individually if required. [. . . ] There are DC voltages on the trawl cable that are capable of delivering a lethal electric shock!The minimum voltage at the trawl unit is 55 Vdc and the current should be approximately 250 mA with sonar head only connected and 325 mA with both sonar head and sensor module (current readings will vary depending on operation mode i. e. , scan speed and range, etc. ). This test is recommended more for a service representative than ship's personnel in the field. · Test for Water In Cable When a trawl cable is damaged or there is a poor splice, salt water can get into the cable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD FS20

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD FS20 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag