User manual SIMRAD SH80 REV C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIMRAD SH80. We hope that this SIMRAD SH80 user guide will be useful to you.

Lastmanuals help download the user guide SIMRAD SH80.


Mode d'emploi SIMRAD SH80
Download
Manual abstract: user guide SIMRAD SH80REV C

Detailed instructions for use are in the User's Guide.

[. . . ] Operator manual Simrad SH80 High frequency fishery sonar www. simrad. com MAXIMIZING YOUR PERFORMANCE AT SEA 850-164385 / Rev. C SH80 High frequency fishery sonar Operator manual WARNING The sonar must never be powered up when the ship is in dry dock. The transducer will be damaged if it transmits in open air. To prevent inadvertent use of the sonar, pull out the mains plug on the Sonar Processor Unit whenever the vessel is in dry dock. About this document Rev Rev. C Date 11. 02. 05 Written by RBr Checked by SØJ Approved by OBG Updated for software version 1. 2. X © 2005 Simrad AS ISBN 82-8066-007-0 All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Simrad AS. [. . . ] Print - Allows you to print the stored picture to the default printer (if any). The following other parameters are available: Store, page 135 Store Mode, page 135 Recall, page 124 Recall Mode, page 124 The Close button closes this menu. The Help button opens the on-line help. 850-164385 / Rev. C 65 Simrad SH80 System test The System test menu is activated by the Test button in the Setup menu. The System test menu provides several test routines available to perform operational and functional tests. These tests are designed only to be carried out by qualified service engineers. Parameters Test Configuration - This function is only to be activated by qualified service engineers. Test Function - This function is only to be activated by qualified service engineers. Toggle TxPower - This function is only to be activated by qualified service engineers. Test Beam - This function is only to be activated by qualified service engineers. Echo Level - This button provides a readout of the current noise in the waters surrounding the vessel. This noise is caused by air bubbles, water flow and mechanical disturbances from hull and engine. In order to obtain the best possible sonar result, the noise level readout should be as close to 0. 0 dB as possible. Roll - This is not a button, it is a readout from the sensor of the actual roll value at the time of the last transmission. Pitch - This is not a button, it is a readout from the sensor of the actual pitch value at the time of the last transmission. TRU Temp- This button provides a readout of the current temperature inside the Transceiver Unit. If the temperature rises to an unacceptable level, an alarm will be given. Interpolation - This is a built-in software function that may give a more realistic presentation of the echos. Message bar - This button opens the Message bar parameter dialogue, which allows you to monitor operational messages from the sonar. Installation menu - This button opens the Installation menu on the top of the display. This menu is used during installtion of the sonar, and information about this is provided in the Installation manual. 66 850-164385 / Rev. C Menu descriptions About - This button provides access to a small information dialogue providing the current software version. The Help button opens the on-line help. Related topics Message bar, page 111 About, page 85 850-164385 / Rev. C 67 Simrad SH80 Sort Modes The Sort Modes menu is activated by the Sort Modes button in the Setup menu. The Sort Modes menu is used to select the display modes to be activated by the four Mode buttons on the Sonar Operating Panel. The four upper display modes in this menu will always be the four modes selectable by the four Mode buttons in the order they are sorted. [. . . ] Remember to set the hoisting/lowering switch back to Remote for normal operation. 850-164385 / Rev. C 159 Simrad SH80 Cleaning the transducer The transducer normally needs little attention. However, the transducer face should be inspected and cleaned whenever the vessel is in dock. To lower the transducer when in dock, use the hoist/lower switch S302 in the Motor Control Unit (mounted on the gantry). Set the switch to STOP to position the transducer at any vertical location. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD SH80

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD SH80 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag