User manual SIMRAD SP90 REV E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIMRAD SP90. We hope that this SIMRAD SP90 user guide will be useful to you.

Lastmanuals help download the user guide SIMRAD SP90.


Mode d'emploi SIMRAD SP90
Download
Manual abstract: user guide SIMRAD SP90REV E

Detailed instructions for use are in the User's Guide.

[. . . ] Operator manual Simrad SP90 Low frequency long range fishery sonar www. simrad. com MAXIMIZING YOUR PERFORMANCE AT SEA 850-164511 / Rev. E SP90 Low frequency long range fishery sonar Operator manual WARNING The sonar must never be powered up when the ship is in dry dock. The transducer will be damaged if it transmits in open air. To prevent inadvertent use of the sonar, pull out the mains plug on the Sonar Processor Unit whenever the vessel is in dry dock. About this document Rev Rev. E Date 17. 12. 04 Written by RBr Checked by OBG Approved by OBG Complies to software version 1. 2. X Added and changed parameter and maintenance details. © 2004 Simrad AS ISBN 82-8066-003-8 All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Simrad AS. [. . . ] These tests are designed only to be carried out by qualified service engineers. Test parameters Test Configuration - This function is only to be activated by qualified service engineers. Test Function - This function is only to be activated by qualified service engineers. Toggle TxPower - This function is only to be activated by qualified service engineers. Test Beam - This function is only to be activated by qualified service engineers. Echo Level - This button provides a readout of the current noise in the waters surrounding the vessel. This noise is caused by air bubbels, water flow and mechnical disturbances from hull and engine. In order to obtain the besst possible sonar result, the noise level readout should be as close to 0. 0 dB as possible. Roll - This is not a button, it is a readout from the sensor of the actual roll value at the time of the last transmission. Pitch - This is not a button, it is a readout from the sensor of the actual pitch value at the time of the last transmission. TRU Temp- This button provides a readout of the current temperature inside the Transceiver Unit. If the temperature rises to unacceptable levels, and alarm will be given. Interpolation - This is a built-in software function that may give a more realistic presentation of the echos. Message bar - This button opens the Message bar parameter dialogue, which allows you to monitor operational messages from the sonar. Installation menu - This button opens the Installation menu on the top of the display. This menu is used during installtion of the sonar, and information about this is provided in the Installation manual. 68 850-164511 / Rev. E Menu descriptions About - This button provides access to a small information dialogue providing the current software version. The Help button opens the on-line help. Related topics Message bar, page 116 About, page 87 850-164511 / Rev. E 69 Simrad SP90 Sort Modes The Sort Modes menu is activated by the Sort Modes button in the Setup menu. The Sort Modes menu is used to select the display modes to be activated by the four Mode buttons on the Sonar Operating Panel. The four upper display modes in this menu will always be the four modes selectable by the four Mode buttons in the order they are sorted. In order to sort the modes, select the actual mode and use the Move Up and Move Down buttons to place it in the wanted position. When the modes are organized in the requested order, press the Apply button to store the information. Related topics Mode buttons, Operator Panel, page 29 Mode buttons, page 118 70 850-164511 / Rev. E Menu descriptions Pop-up menus The pop-up menus are accessed using the View and Object buttons on the Sonar Operating Panel, or the middle and right mouse buttons if an optional mouse is installed. Each button will present a small menu, and it appears at the cursor's current location. To make a selection, use the trackball and the Select button, or the mouse. Pop-up menus View, page 72 Object, page 74 Related topics View and Object buttons, page 32 850-164511 / Rev. E 71 Simrad SP90 View pop-up The View pop-up menu is accessed using the View button over the trackball on the Sonar Operating Panel or the middle mouse button if an optional mouse is installed. When activating the pop-up menu in the Catch Data view, it will display the following reduced menu. View pop-up parameters Set New Display Centre - When this function is selected, the new display centre is moved to the cursor's position where the View menu was activated. [. . . ] The motor will automatically stop when the transducer shaft reaches the upper or lower limit switch. Remember to set the switch back to Remote position when finished. Hoist/lower contactors K301 and K302 If the 3-phase voltage for the hoist/lower motor is available, the transducer can be hoisted and lowered by operating the hoist (K301) and lower (K302) contactors in the Motor Control Unit by activating the small switch handle on the front of the contactor. Warning The switches must be released before the transducer shaft reaches upper or lower position, as this operation overrides the two limit switches. Manual hoist and lower operation If the 3-phase voltage is not available, the transducer must be hoisted and lowered by means of the hand crank. Locate the motor overload switch S301 in the Motor Control Unit, and press the red button marked 0. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD SP90

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD SP90 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag