User manual SIMRAD TRANSDUCER MOUNTING ARRANGEMENT SCHEMA REV F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIMRAD TRANSDUCER MOUNTING ARRANGEMENT. We hope that this SIMRAD TRANSDUCER MOUNTING ARRANGEMENT user guide will be useful to you.

Lastmanuals help download the user guide SIMRAD TRANSDUCER MOUNTING ARRANGEMENT.


Mode d'emploi SIMRAD TRANSDUCER MOUNTING ARRANGEMENT
Download
Manual abstract: user guide SIMRAD TRANSDUCER MOUNTING ARRANGEMENTSCHEMA REV F

Detailed instructions for use are in the User's Guide.

[. . . ] The user must be familiar with the contents of the appropriate manuals before attempting to install, operate or work on the equipment. Kongsberg Maritime AS disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Support information If you require maintenance or repair, contact your local dealer. You can also contact us using the following address: -. If you need information about our other products, visit our web site. [. . . ] Switch off the Interference Filter filter. Adjust the level of the Detection Threshold (DT). a b Make sure that the Interference Filter is switched off. Normal ranges up to 1500 meters: If you experience poor reception with the sensors in the sea, try to increase the detection threshold until the data reception appears completely random. Then, decrease the parameter until you have stable data reception. If you have interference problems while no sensors have been deployed, try to decrease the detection threshold until you have a stable data reception. c Long ranges above 1500 meters: Initially, use the same strategy as for normal range. However, if those actions are not enough to provide stable readings, try to set the detection threshold to 8. If your vessel's self noise and interference is lower than normal, you may achieve a range enhancement by using this value. If interference cause problems, try to increase the detection threshold value until the interference disappears. 6 Click OK to save the current settings and close the dialog. 100 328458/A Operational procedures Alarms and messages Topics · How to read and acknowledge alarms and messages on page 101 · How to set up sensor alarms on page 101 · How to access the log files on page 102 How to read and acknowledge alarms and messages Messages could be related to any type of hardware or software error, and even events related to operational conditions. b Click to enable message and/or audio notification To disable all alarms, remove all Message and Audio selections. Click OK to save the current settings and close the dialog. How to access the log files Whenever the TRANSDUCER MOUNTING ARRANGEMENT issues a message, it is shown in the Messages dialog. Simultaneously, the messages are stored in a number of logging files on the hard disk. If you experience abnormal behaviour, and wish to consult your dealer and/or Simrad, these logging files are very useful. The following procedure explains how to access these files. 1 Click the Display icon under the Main menu to open the Display sub-menu. 2 Click Screen Captures to open an operating system folder. By default, the folder name is c:\documents and settings\All Users\Application data\Simrad\TRANSDUCER MOUNTING ARRANGEMENT\ScreenDumps 3 Screen Captures on page 139 In the folder, go one step "back" (up) to: c:\documents and settings\All Users\Application data\Simrad\TRANSDUCER MOUNTING ARRANGEMENT 4 5 6 Observe that a folder named Log is now visible. The folder contains all recent log files containing the TRANSDUCER MOUNTING ARRANGEMENT messages. Using the functionality provided by the operating system, copy the log files to a USB memory stick. 102 328458/A Operational procedures Whenever possible, send the files to your dealer. 7 Close the folder. 328458/A 103 Simrad TRANSDUCER MOUNTING ARRANGEMENT Software procedures If the TRANSDUCER MOUNTING ARRANGEMENT system is provided with a computer, it is delivered with all necessary software installed, configured and tested. If you use your own computer, you must do this yourself. Software upgrades are useful if your TRANSDUCER MOUNTING ARRANGEMENT fails, and you suspect a software error. [. . . ] Format $--GGA, hhmmss. ss, llll. ll, a, yyyyy. yy, a, x, zz, d. d, a. a, M, g. g, M, r. r, cccc*hh<CR><LF> Format description 1 ­ ­ = talker identifier 2 GGA = telegram identifier 3 hhmmss. ss = coordinated universal time (UTC) of position 4 llll. ll, a = latitude north/south, position in degrees, minutes and hundredths. Characters N (North) or S (South) identifies the bearing. 5 yyyyy. yy, a = longitude east/west, position in degrees, minutes and hundredths. Characters W (West) or E (East) identifies the bearing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD TRANSDUCER MOUNTING ARRANGEMENT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD TRANSDUCER MOUNTING ARRANGEMENT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag