User manual SIMRAD TRANSDUCER MOUNTING PLATE SCHEMA REV A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SIMRAD TRANSDUCER MOUNTING PLATE. We hope that this SIMRAD TRANSDUCER MOUNTING PLATE user guide will be useful to you.

Lastmanuals help download the user guide SIMRAD TRANSDUCER MOUNTING PLATE.


Mode d'emploi SIMRAD TRANSDUCER MOUNTING PLATE
Download
Manual abstract: user guide SIMRAD TRANSDUCER MOUNTING PLATESCHEMA REV A

Detailed instructions for use are in the User's Guide.

[. . . ] Improper use or maintenance may cause damage to the equipment and/or injury to personnel. The user must be familiar with the contents of the appropriate manuals before attempting to install, operate or work on the equipment. Kongsberg Maritime AS disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Support information If you require maintenance or repair, contact your local dealer. You can also contact us using the following address: -. [. . . ] a Locate the Ethernet port you wish to use. If no Ethernet port is available, an Ethernet switch may be inserted between the computer and the transceiver. b Connect an Ethernet cable from the TRANSDUCER MOUNTING PLATE computer to the peripheral system. We strongly recommend that you use high quality Ethernet cables, minimum CAT-5. RJ45 Ethernet, straight on page 40 3 Click the Setup icon under the Main menu to open the Setup sub-menu. 4 Click Navigation to open the Navigation dialog. 5 For each tab: a b c Select which port to use. Click Setup for the selected port to define the communication parameters. If you choose Auto, the TRANSDUCER MOUNTING PLATE will automatically choose among the incoming information according to a predefined priority list. d If applicable, define the Talker ID. 6 Click OK to save the current settings and close the dialog. 58 328459/A Drawing file Drawing file This chapter contains relevant drawings related to the electrical and physical installation of the Simrad TRANSDUCER MOUNTING PLATE. Note The mechanical drawings are for information and guidance only. All dimensions are in mm unless otherwise is noted. The original installation drawings are available on PDF and/or AutoCad's DWG format. Visit www. simrad. com to download. Topics · · · TRANSDUCER MOUNTING PLATE Marine computer on page 60 TRANSDUCER MOUNTING PLATE Receiver Unit on page 61 Power Supply for TRANSDUCER MOUNTING PLATE Receiver Unit on page 62 328459/A 59 Simrad TRANSDUCER MOUNTING PLATE TRANSDUCER MOUNTING PLATE Marine computer 60 328459/A Drawing file TRANSDUCER MOUNTING PLATE Receiver Unit 328459/A 61 Simrad TRANSDUCER MOUNTING PLATE Power Supply for TRANSDUCER MOUNTING PLATE Receiver Unit 62 328459/A Technical specifications Technical specifications This chapter lists the main technical specifications for the Simrad TRANSDUCER MOUNTING PLATE. Note We reserve the right to alter technical specifications without prior notice. A complete description of each sensor is provided on Simrad's website http://www. simrad. com and in the individual sensor instruction manuals. 68 328459/A PI sensors PI Bottom Contact purpose and application This is an S-type PI sensor. To charge this sensor, use the Simrad PI Charger or the Simrad PI MiniCharger. Figure 10 PI Bottom Contact application A B The trawl follows the bottom. The detection wire on the sensor is not released. The trawl has lifted off the bottom, and the detection wire is released. The purpose of the Simrad PI Bottom Contact sensor is to detect if a bottom trawl is accidentally lifted up from the seabed. This will allow fish to escape under the gear. · On a pelagic trawl, the sensor will notify you if you move the gear too close to the bottom. · Used on a purse seine you will be notified once the seine reaches the bottom, and this allows you to fish even on a rough bottom. · On a Danish seine the Simrad PI Bottom Contact sensor will let you know when the net has a stable bottom contact, and when it is time to haul. 328459/A 69 Simrad TRANSDUCER MOUNTING PLATE PI Catch purpose and application This is an S-type PI sensor. To charge this sensor, use the Simrad PI Charger or the Simrad PI MiniCharger. Figure 11 PI Catch application Using the Simrad PI Catch sensor, you can easily monitor the filling rate and the amount of catch in the trawl. [. . . ] If the situation is unavoidable, a loop of cable having a length proportional to the possible expansion of the joint must be provided. The minimum internal radius of the loop must be at least twelve times the external diameter of the cable. · Where a service requires duplicate supply lines, the cables must follow separate paths through the vessel whenever possible. · Signal cables must not be installed in the same cable tray or conduit as high-power cables. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD TRANSDUCER MOUNTING PLATE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD TRANSDUCER MOUNTING PLATE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag