User manual SKIL 0790

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SKIL 0790. We hope that this SKIL 0790 user guide will be useful to you.

Lastmanuals help download the user guide SKIL 0790.


Mode d'emploi SKIL 0790
Download
Manual abstract: user guide SKIL 0790

Detailed instructions for use are in the User's Guide.

[. . . ] Garden blower/vacuum 0790 (F0150790. . ) ME77 GB F D NL S DK N FIN E P I H CZ TR PL RU ORIGINAL INSTRUCTIONS UAGB NOTICE ORIGINALE ORIGINALBETRIEBSANLEITUNG D ORIGINELE GEBRUIKSAANWIJZING NL BRUKSANVISNING I BG S ORIGINAL ORIGINAL BRUGSANVISNING DK 6 8 11 14 17 20 22 25 28 31 34 37 39 42 45 48 UA GR RO BG SK HR GR RO F INSTRUCIUNI DE FOLOSIRE ORIGINALE PÔVODNÝ NÁVOD NA POUZITIE ORIGINALNE UPUTE ZA RAD 51 54 58 61 64 67 70 72 75 78 81 91 89 N ORIGINAL BRUKSANVISNING FIN ALKUPERÄISET OHJEET MANUAL ORIGINAL MANUAL ORIGINAL SK HR SRB SLO EST LV LT E P SRB ORIGINALNO UPUTSTVO ZA RAD SLO IZVIRNA NAVODILA EST ALGUPÄRANE KASUTUSJUHEND LV LT AR FA ORIINL LIETOSANAS PAMCBA ORIGINALI INSTRUKCIJA ISTRUZIONI ORIGINALI I H EREDETI HASZNÁLATI UTASÍTÁS CZ PVODNÍM NÁVODEM K POUZÍVÁNÍ TR ORJNAL LETME TALMATI PL INSTRUKCJA ORYGINALNA RU FA AR AR AR FA FA www. skileurope. com SKIL Europe BV - Konijnenberg 60 4825 BD Breda - The Netherlands 07/10 2610Z01198 1 0790 2800 Watt EPTA 01/2003 3, 8 kg 2 D Q R K F J L E 3 G M C B 4 5 A S H N P 6 XX 2 7 8 9 0 ! 3 @ # $ % 4 ^ Q R & 5 GB Garden blower/vacuum InTroducTIon 0790 · Thistoolhasbeendesignedforblowing/collectingas well as vacuuming/shredding dry leaves and other dry garden rubbish such as grass and twigs · Thistoolisintendedfordomesticuseonlyandisnot designed to be used under wet conditions · Thistoolisnotintendedforprofessionaluse · Readthisinstructionmanualcarefullybeforeuse andsaveitforfuturereference3 · Payspecialattentiontothesafetyinstructionsand warnings;failuretofollowthesemayresultin seriousinjury · Checkwhetherthepackagingcontainsallpartsas illustrated in drawing 2 · Whenpartsaremissingordamaged, pleasecontact your dealer TECHNICALSPECIFICATIONS1 Tool elemenTS 2 a Lower blower/suction tube b Upper blower/suction tube c Collection bag d Shoulder strap e Cord restraint F On/offswitch G Switchforselectingoperatingmode H Supporting wheels J Ventilation slots K Main handle l Guide handle m Fastening screws (4) n Vacuum opening P Blower opening Q Storage rail (screwsnotsupplied) r Storage hook S Nameplate SAFETY General · Onlyusethetoolindaylightorwithappropriate artificial lighting · Onlyusethetoolwhencompletelyassembled · Donotusethetoolonwetlawnsandwhenthe materials to be blown/vacuumed are wet · Donotblowatortowardshot, flammableor explosive materials · Donotvacuumhot, flammableorexplosivematerials · Neveroperatethetoolinthedirectvicinityofpersons (especially children) and animals · Theuserisresponsibleforaccidentsorhazards occurring to other people or their property · Alwaysdisconnectplugfrompowersource - whenever leaving the tool unattended - beforeclearingjammedmaterial 6 - beforechecking, cleaningorworkingonthetool - whenever the tool starts vibrating abnormally · Storethetoolindoorsinadryandlocked-upplace, outofreachofchildren PERSONALSAFETY · Thistoolisnotintendedforusebypersons (includingchildren)withreducedphysical, sensory ormentalcapabilities, orlackofexperienceand knowledge, unlesstheyhavebeengivensupervision orinstructionconcerninguseofthetoolbyaperson responsiblefortheirsafety · Ensurethatchildrendonotplaywiththetool · Neverallowchildrentousethetool · Neverblowdebrisinthedirectionofbystanders · Alwayswearlongtrousers, longsleevesandsturdy shoes when operating the tool · Wearprotectivegloves, safetyglasses, close-fitting clothesandhairprotection(forlonghair) · Wearadustmaskwhenworkinginadustyenvironment ELECTRICALSAFETY · Alwayscheckthatthesupplyvoltageisthesameasthe voltageindicatedonthenameplateofthetool(tools witharatingof230Vor240Vcanalsobeconnectedto a 220V supply) · Connectthetoolviaafaultcurrent(FI)circuitbreaker withatriggeringcurrentof30mAmaximum · Usecompletelyunrolledandsafeextensioncordswith acapacityof16Amps(U. K. 13Amps) · Onlyuseanextensioncordwhichisintendedfor outdoor use and equipped with a watertight plug and coupling-socket · Onlyuseextensioncordswithamaximumlengthof 20metres(1, 5mm²)or50metres(2, 5mm²) · Alwaysswitchofftoolanddisconnectplugfrompower sourceifthepowersupplycordortheextensioncordis cut, damagedorentangled(donottouchthecord beforedisconnectingtheplug) · Protectthe(extension)cordfromheat, oilandsharp edges · Neverusethecordforcarrying, pullingorunplugging the tool · Inspectthecordperiodicallyandhaveitreplacedbya qualifiedperson, ifdamaged · Inspecttheextensioncordperiodicallyandreplaceit, if damaged (inadequateextensioncordscanbe dangerous) · Donotusethetooliftheswitchdoesnotturnitonand off;alwayshaveadamagedswitchrepairedbya qualified person BEFOREUSE · Befamiliarwiththecontrolsandtheproperuseofthe tool · Checkthefunctioningofthetoolbeforeeachuseand, incaseofadefect, haveitrepairedimmediatelybya qualifiedperson;neveropenthetoolyourself · Beforeuse, thoroughlyinspecttheareawherethe toolistobeusedandremoveallsolidobjectsthat coulddamagetheshreddingmechanismwhen vacuuming(suchasstones, brokenglass, piecesofmetal) · Whenvacuuming, neverusethetoolwithoutthe collection bag in place · Regularlycheckthecollectionbagforwearordamage · Replacewornofdamagedparts · Keepallnuts, boltsandscrewstighttobesurethatthe toolisinasafeworkingcondition durInG uSe · Alwayskeepthecordawayfrommovingpartsofthe tool;directthecordtotherear, awayfromthetool · Operatethetoolatawalkingpaceonly(donotrun) · Keepproperfootingonslopes · Alwaysensurethattheventilationopeningsarekept clearofdebris · Takeasecurestancewhenworking(donotoverreach, especially when using steps or a ladder) EXPLANATIONOFSYMBOLSONTOOL 3 Readtheinstructionmanualbeforeuse 4 Wear protective glasses 5 Do not expose tool to rain 6Payattentiontotheriskofinjurycausedbyflying debris(keepbystandersasafedistanceawayfrom work area) 7Switchoffanddisconnectplugbeforecleaning/ maintenanceorif(extension)cordisdamagedor entangled 8 Double insulation (no earth wire required) WHEN CONNECTING NEW 3-PIN PLUG (U. K. [. . . ] switchoffthetoolanddisconnecttheplug - waituntiltheimpellercomestoastandstillbefore removingthecollectionbagfromthetool - openthezipperofthecollectionbagand empty it completely - compostic material does not belong with domestic waste maInTenance / ServIce · Thistoolisnotintendedforprofessionaluse · Alwayskeeptoolandcordclean(especiallyventilation slots J 2) - clean the tool aftereachusewithasoftbrushora cloth (do not use cleaning agents or solvents) - remove the collection bag aftereachuse, turnit inside out and brush it thoroughly - afterremovingthecollectionbag, ensurethat possibledirtresiduesareremovedfromthereleased air outlet area · Storage^ - securely mount storage rail Q on the wall with 4 screws (notsupplied)andhorizontallyleveled - use storage rail Q and storage hook R as illustrated - store the tool indoorsinadryandlocked-upplace, outofreachofchildren - do not cover the tool with plastic (plastic may cause moisture with rust/corrosion as a result) · Ifthetoolshouldfaildespitethecaretakenin manufacturingandtestingprocedures, repairshould becarriedoutbyanafter-salesservicecentrefor SKIL power tools - send the tool undismantledtogetherwithproofof purchase to your dealer or the nearest SKIL service station(addressesaswellastheservicediagramof the tool are listed on www. skileurope. com) TroubleSHooTInG · Thefollowinglistingshowsproblemsymptoms, possiblecausesandcorrectiveactions(ifthesedo notidentifyandcorrecttheproblem, contactyour dealer or service station) !switchoffthetoolanddisconnecttheplug beforeinvestigatingtheproblem uSe · Assemblyinstructions9 - ensure that tubes A and B and collection bag C are assembled correctly and that shoulder strap D is adjustedcorrectlybeforeoperatingthetool !firmlytightenallscrews, boltsandnuts · Cordrestraint0 - hook the loop in the extension cord over restraint E as illustrated - pull tight to secure the extension cord · On/off!- switchon/offthetoolbypushingswitchF2 in "I"/"O" position ! [. . . ] donotvacuumsolidobjectssuchasstones, brokenglass, piecesofmetal - do not vacuum liquids - donotvacuumlargevolumesofleafmaterialatone timethusavoidingcloggingofthevacuuming openingandblockingoftheshredderimpeller 7 Tool does not operate - no power supply -> check power supply (powercable, circuitbreakers, fuses) - plug not connected -> connect plug - extension cord damaged -> replace extension cord - on/offswitchdefective->contactdealer/service station - worn carbon brushes -> contact dealer/service station - defectivemotor->contactdealer/servicestation - blowing/vacuum tube not completely mounted -> mount two-part blowing/vacuum tube Tool operates intermittently - on/offswitchdefective->contactdealer/service station - internalwiringdefective->contactdealer/service station - impellerblockedbyforeignobject->remove blockage No/low blowing power - selector switch in vacuuming mode -> set selector switch in blowing mode No/low vacuuming power - selector switch in blowing mode -> set selector switch in vacuuming mode - collectionbagisfull/dirty->empty/cleancollection bag - vacuumingopeningcloggeduporblockedbyforeign object -> remove blockage noISe/vIbraTIon · MeasuredinaccordancewithEN/ISO3744thesound pressurelevelofthistoolis77. 1dB(A)andthesound powerlevel97. 1dB(A)(standarddeviation:2. 2dB), and thevibration7. 4m/s²(hand-armmethod;uncertainty K=1. 5m/s²) · Measuredinaccordancewith2000/14/EC(EN/ISO3744) the guaranteed sound power level LWA is lower than 100dB(A)(conformityassessmentprocedureaccording to Annex V) · Thevibrationemissionlevelhasbeenmeasuredin accordance with a standardised test given in EN/ISO3744;itmaybeusedtocompareonetoolwith anotherandasapreliminaryassessmentofexposure tovibrationwhenusingthetoolfortheapplications mentioned - usingthetoolfordifferentapplications, orwith differentorpoorlymaintaintedaccessories, may significantly increase the exposure level - thetimeswhenthetoolisswitchedofforwhen itisrunningbutnotactuallydoingthejob, may significantly reduce the exposure level ! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SKIL 0790

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SKIL 0790 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag