User manual SKYPE EP10A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SKYPE EP10A. We hope that this SKYPE EP10A user guide will be useful to you.

Lastmanuals help download the user guide SKYPE EP10A.


Mode d'emploi SKYPE EP10A
Download
Manual abstract: user guide SKYPE EP10A

Detailed instructions for use are in the User's Guide.

[. . . ] To prevent personal injury from refrigerants, operators must wear safety glasses, gloves and protective clothing. Refrigerant and oil health and safety information may be obtained from refrigerant and lubricant manufacturers. Do not use this equipment in the vicinity of spilled or open containers of gasoline. Safety devices require the use of authorized tanks only. [. . . ] This confirms that the float shut off device is functioning properly. YOUR MACHINE IS NOW READY FOR USE Note: The machine must be precharged with refrigerant to at least 14 PSI before the compressor will start. This can be accomplished by connecting to the AC system to be serviced if it is charged with refrigerant. TO RECOVER REFRIGERANT IMPORTANT: Before recovering refrigerant with the SKYE machine, the AC system must be off. 6 NOTES: The PURGE VALVE must be open completely for the machine to perform the recovery function. The sight glass on this machine is used to monitor refrigerant input to the compressor. There should never be liquid refrigerant flowing through the sight glass. If liquid refrigerant is detected during recovery, immediately press the OFF switch to prevent damage to the compressor. Liquid refrigerant flow through the sight glass indicates a malfunction of the flow controller mounted on the machine's inlet line. Connect the unit to power, connect the outlet hose to the storage tank vapor port and open the storage tank vapor valve. Connect the gauge set RED and BLUE service hoses to the AC system and the YELLOW hose to the machine inlet port. Press the green ON button and slowly open the BLUE and RED gauge hand valves. The compressor will start and refrigerant will be recovered. When the pressure in the AC system drops to approximately 10" VACUUM the compressor will stop. This does not mean all the refrigerant in the system has been recovered as there may be refrigerant trapped in the oil or an accumulator/drier that will slowly evaporate. The compressor will restart automatically and recover this refrigerant. When the gauges remain at 0 PSI or below for at least 2 minutes recovery is complete. Close the gauge set valves and press the red OFF button. Drain the recovered oil into the container provided and dispose of following local, state and federal regulations. EQUIPMENT MAINTENANCE WARNING: Prior to servicing this machine refrigerant must be removed (purged) from the unit and power must be disconnected. Close the PURGE VALVE located on the side of the machine. Connect the storage tank end of the outlet hose to the machine inlet port. Connect the quick connect fitting end of the purge hose to the quick connect fitting on the side of the machine and the threaded end to the storage tank vapor port then open the storage tank vapor valve. Connect the machine to power and press the green ON button. When the purge process is complete the compressor will stop automatically. [. . . ] This product is warranted by SKYE International Holdings, Inc. to the original retail consumer against defects in materials and workmanship for a period of one year from the date of purchase except for the compressor which has a three month warranty. The warranty is not transferable. 11 Except as otherwise provided for by law, this guarantee becomes invalid if in the opinion of the company the product has been misused, abused, damaged in transit, incorrectly operated, tampered with by an unauthorized person or connected to an electrical supply not corresponding with the specifications or if incorrect refrigerant was used. Failure to perform normal maintenance, the use of incorrect oil or compressors damaged by allowing the ingress of liquid refrigerant will also invalidate the warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SKYPE EP10A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SKYPE EP10A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag