User manual SKYPE EP10M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SKYPE EP10M. We hope that this SKYPE EP10M user guide will be useful to you.

Lastmanuals help download the user guide SKYPE EP10M.


Mode d'emploi SKYPE EP10M
Download
Manual abstract: user guide SKYPE EP10M

Detailed instructions for use are in the User's Guide.

[. . . ] SKYE® AIR CONDITIONING SERVICE EQUIPMENT OWNERS MANUAL MODEL EP10M MULTIPLE REFRIGERANT RECOVERY SYSTEM WARNING: DO NOT MIX ANY REFRIGERANTS July 11, 2000 SKYE International Holdings, Inc. 7441 Tower Street Fort Worth, Texas 76118 Phone: (817) 595-0077 FAX: (817) 595-1106 FOR TECHNICAL SUPPORT AND CUSTOMER SERVICE, PLEASE CALL 1-800-722-SKYE (7593) RECORD YOUR EQUIPMENT DETAILS BELOW: MODEL NO. _____________________________________ SERIAL NO. _____________________________________ DATE PURCHASED _____________________________________ PURCHASED FROM _____________________________________ Thank you for choosing SKYE AC Service Equipment. With proper set up and maintenance, your equipment will provide years of trouble free service. [. . . ] On units equipped with a tank float only, disconnect the float lead from the tank connection and press the green ON switch. The RED tank full light will illuminate. This confirms that the float shut off device is functioning properly. YOUR MACHINE IS NOW READY FOR USE Note: The machine must be precharged with refrigerant to at least 14 PSI before the compressor will start. This can be accomplished by connecting to the AC system to be serviced if it is charged with refrigerant. TO RECOVER REFRIGERANT IMPORTANT: Before recovering refrigerant with the SKYE machine, the AC system must be off. NOTES: The PURGE VALVE must be open completely for the machine to perform the recovery function. 6 The sight glass on this machine is used to monitor the refrigerant input to the compressor. There should never be liquid refrigerant flowing throught the sight glass. If liquid refrigerant is detected during recovery, immediately press the OFF switch to prevent damage to the compressor. Liquid refrigerant flow through the sight glass indicates a malfunction of the flow controller mounted on the machine's inlet line. Connect the unit to power, connect the outlet hose to the storage tank vapor port and open the storage tank vapor valve. Connect the gauge set RED and BLUE service hoses to the AC system and the YELLOW hose to the machine inlet port. Press the green ON button and slowly open the BLUE and RED gauge hand valves. The compressor will start and refrigerant will be recovered. When the pressure in the AC system drops to approximately 10" VACUUM the compressor will stop. This does not mean all the refrigerant in the system has been recovered as there may be refrigerant trapped in the oil or an accumulator/drier that will slowly evaporate. The compressor will restart automatically and recover this refrigerant. When the gauges remain at 0 PSI or below for at least 2 minutes with the compressor off, recovery is complete. Close the gauge set valves and press the red OFF button. Drain the recovered oil into the container provided and dispose of following local, state and federal regulations. EQUIPMENT MAINTENANCE WARNING: Prior to servicing this machine refrigerant must be removed (purged) from the unit and power must be disconnected. Close the PURGE VALVE located on the side of the machine. Connect the storage tank end of the outlet hose to the machine inlet port. [. . . ] If a slight flow of oil is present, the compressor oil level is correct. If a tilt of more than five (5) degrees is required to obtain oil flow the compressor oil level is low. Change the compressor oil following the compressor oil change procedure from page 8. COMPRESSOR OIL SEPARATOR CAPILLARY LINE SERVICE If the oil return capillary line on the compressor oil separator becomes plugged follow the procedures below. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SKYPE EP10M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SKYPE EP10M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag