User manual SMEG GM287-110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG GM287-110. We hope that this SMEG GM287-110 user guide will be useful to you.

Lastmanuals help download the user guide SMEG GM287-110.


Mode d'emploi SMEG GM287-110
Download
Manual abstract: user guide SMEG GM287-110

Detailed instructions for use are in the User's Guide.

[. . . ] · Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. · The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE · Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. · Clean and/or replace the Filters after the specified time period. [. . . ] · For wooden beam ceilings, use 4 wood screws (not provided). · For wooden shelf, use 4 screws 12g (M6 x 80) with washers 22 and nuts 23, provided. Lower frame · Fix the lower frame using the 8 previously removed screws, adjusting the length according to the installation height (hood body lower fixing surface must be at least 710 mm from the hob). · For the recirculation version, turn the frame in the direction chosen for the recirculated air outlet. · The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending. · In all cases where the ceiling is not strong enough at the suspension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts. Connections DUCTED VERSION AIR EXHAUST SYSTEM In order to install the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer. ø 150 · Push fit Damper 10 onto the air outlet. · Fix the pipe using the pipe clamps 25 provided. · Remove any activated charcoal filters. 25 10 RECIRCULATION VERSION AIR OUTLET · Assemble the two halves of the hood body extension piece 14. · Push fit the assembled hood body extension piece 14 onto the air outlet. · Push fit connection 15 onto the hood body extension piece 14. Press the button and hold it until Led S1 flashes slowly. V2 Speed V3 Intensive Speed R Increases the operating speed. Maximum speed, used for eliminating the highest cooking vapour emission. Switches off automatically after 10 minutes operation. Can also be switched off manually by pressing the button. Receiver for Optional Remote Control. Remote Control GB 19 MAINTENANCE Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS Alarm signal reset · Switch off the lights and extractor motor. · Press button V2 for at least 3 seconds, until the leds start to flash. Cleaning the filters · The filters must be cleaned when led S1 flashes or at least every 2 months of operation, or more frequently for particularly heavy usage. · Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. · Wash the filters, taking care not to bend them. · When refitting the filters, make sure that the handle is visible on the outside. GB 20 Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER · The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes twice or at least every 4 months. [. . . ] · Replace the Support and fix it in place with the two Screws removed as above. GB 21 Quest'apparecchio è conforme alla norma europea sulla bassa tensione C. E. E. 73/23 relativa alla sicurezza elettrica e alle norme europee: C. E. E. 89/336 relativa alla compatibilità elettromagnetica e C. E. E. This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/ 336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG GM287-110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG GM287-110 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag