User manual SMEG GW6010MP PROGRAMME TABLE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG GW6010MP. We hope that this SMEG GW6010MP user guide will be useful to you.

Lastmanuals help download the user guide SMEG GW6010MP.


SMEG GW6010MP PROGRAMME TABLE: Download the complete user guide (525 Ko)

You may also download the following manuals related to this product:

   SMEG GW6010MP MANUALE D'INSTALLAZIONE (469 ko)

Manual abstract: user guide SMEG GW6010MPPROGRAMME TABLE

Detailed instructions for use are in the User's Guide.

[. . . ] Hot, HW: hot mains water, the type of water used in a specific phase of the program. ID_prog: identity number of the washing program; it is not necessarily bonded to the program name. Int. : “Intensive” – use this program to process dirty elements. [. . . ] N. C. : "NOT CONTROLLED" - refers to the relatively short heating phases during which the heating elements are “on” but no target temperature value is set. P5: the code refers to the activation of the relative peristaltic pump, with dispensing of the liquid detergent associated to it. P1b, P2a: the code refers to dispensing by pump P1, P2 at a rate different from the default rate, used in special cases, as specified in the program table. P1 P1b P2 P2a P3 P4 P1(20), P2(20), P3(20), P4(20) DEFAULT DOSAGE LABORATORY PROGRAMS GLASSWARE WASHER GW [ml/litro] 5 3 3 4 10 0. 4 20 (dosage for service purpose only – peristaltic pump service program) TD: thermal disinfection - phase during which the target temperature is kept above a target value for a specified time. The efficacy of the thermal disinfection process is indicated by means of parameter A0. In preset programs, the target value for a thermal disinfection process is always at least 80°C. The temperature inside the tank is kept constant around the specified value for the time shown in the table. The phase during which the temperature is held at the target value is called the EXTENSION phase. Warning: when creating a custom program, do not include more than two thermal disinfection phases at 93°C for 10min. 19 592 0349 04 GW6010 – GW7010 – PROGRAM TABLE 2 LABORATORY – PROGRAM TABLE Prewashing / Washing / NAOH washing Washing / NAOH washing / Thermo disinfection Neutralization Mains rinsing Demi rinsing Rins. Demi hot Drying phase ID_prog H2O load H2O load H2O load H2O load H2O load H2O load Temp °C Temp °C Temp °C Temp °C Temp °C Temp °C Laboratory programs 1 2 3 4 5 6 7 8 9 10 1 Prewash GW 2 Plastic 3 Glassware - quick 4 Glassware - med. 7 Glassware (blood) 8 Glassware AGAR 9 AGAR Intensive Cold Cold 0 0 5 3 P1 Hot P1 Hot P1 Hot P1 80 90 93 93 93 P4 93 93 93 93 93 P4 93 P4 93 P4 93 P4 10 1 5 3 10 5 10 1 5 3 3 3 5 75 5 75 3 Cold 75 3 Hot P2 Hot P2 Hot P2 Hot P2 Hot P1 Cold P1 Hot P1 Hot P1 P1 Hot P1 P3 Hot Hot P2a Hot P2 Hot P2 Hot P2 Hot P2 Hot P2 Cold P1 Cold P1 Hot P1 P3 Hot P1 P3 Hot P1 P3 Hot P1 P3 Hot P2 Hot P2 Hot P2 Hot P2 Hot P2 Hot P2 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Demi NC 2 Demi 75 1 100 30 NC 2 Demi NC 2 Demi 75 1 100 30 NC 2 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 3 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 3 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 2 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 2 Hot NC 1 Demi NC 1 Demi 75 1 90 30 NC 2 Demi NC 1 Demi 75 1 80 30 NC 2 Demi NC 1 Demi 75 1 80 30 NC 3 Hot NC 1 Demi NC 1 Demi 75 1 80 30 1800 3600 3600 6000 3600 12000 6000 12000 1200 6000 1200 12000 Hot P1 Cold P1 Hot P1 Hot P1 P3 P4 NC 3 3 NC 80 3 3 10 Thermal disin. 16 16 Oil grease 17 17 Mineral Oil Cold P1 Cold P1 Hot Hot P1b Hot P1 P1 P3 Hot P3 P4 P4 NC NC NC NC 50 75 2 2 2 2 2 1 19 592 0349 04 GW6010 – GW7010 – PROGRAM TABLE 3 Cycle time std [min] 10 90 70 73 80 88 96 88 96 80 84 97 101 83 89 94 107 Temperature °C Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) A0 Prewashing / Washing / NAOH washing Washing / NAOH washing / Thermo disinfection Neutralization Mains rinsing Demi rinsing Rins. Hot demi Drying phase H2O load H2O load H2O load H2O load H2O load H2O load Temp °C Temp °C Temp °C Temp °C Temp °C Temp °C 18 19 20 18 Petrol 19 Diesel 20 Universal Petrol Hot P1 P1 P3 Hot P3 P4 P4 93 10 NC 3 Hot P1 P1 P1 P3 Hot P3 Hot P3 P4 P4 P4 93 93 93 5 1 10 Hot P2 Hot P2 Hot P2a NC NC NC 2 2 2 Hot Hot Hot NC NC NC 2 2 2 Demi Demi Demi NC NC NC 2 2 1 Demi Demi Demi 75 75 75 1 1 1 100 100 100 30 30 30 6000 1200 12000 A0 Ao Laboratory programs 82 95 123 CUSTOM PROGRAMS On laboratory glassware washers, all the 20 pre-set custom programs have the same structure (as shown in the table below). Prewashing / Washing / NAOH washing Washing / NAOH washing / Thermo disinfection Neutralization Mains rinsing Demi rinsing Rins. Hot demi Drying phase Temperature °C Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) ID_prog H2O load H2O load H2O load H2O load H2O load H2O load H2O load Temp °C Temp °C Temp °C Temp °C Temp °C Temp °C Custom: Program name 21 22 23 … 40 Custom 1 Custom 2 Custom 3 … Custom 20 Temp °C DW (18) DW (18) DW (18) DW (18) DW (18) - 1 1 1 1 1 - - - 19 592 0349 04 GW6010 – GW7010 – PROGRAM TABLE 4 Cycle time std [min] ID_prog Temperature °C Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) SERVICE PROGRAMS Prewashing / Washing / NAOH washing Washing / NAOH washing / Thermo disinfection Neutralization Mains rinsing Demi rinsing Rins. Hot demi Drying phase Temperature °C Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Service Programs: Program name 200 Empty boiler 201 Drying Service 1 202 (peristaltic pump test) Probes calibration 203 (TL, TCL) CW P1(20)+P3(20) DW 93 10 0 CW P2(20) 0 CW P4(20) 0 DW 1 100 30 - - - 90 10 Recommended use of the service programs: - Program "200 Empty boiler": only for devices with boiler, the program performs an emptying of the boiler, recommended before periods of inactivity of the device. - Program "201 Drying": performs a drying step in itself - to be used if the load drying was partial / not completely effective. [. . . ] Hot demi Drying phase Temperature °C Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Service Programs: Program name 200 Empty boiler 201 Drying Service 1 202 (peristaltic pump test) Probes calibration 203 (TL, TCL) CW P1(20)+P3(20) DW 93 10 0 CW P2(20) 0 CW P4(20) 0 DW 1 100 30 - - - 90 10 Recommended use of the service programs: - Program "200 Empty boiler": only for devices with boiler, the program performs an emptying of the boiler, recommended before periods of inactivity of the device. - Program "201 Drying": performs a drying step in itself - to be used if the load drying was partial / not completely effective. - Program “202 Service 1” It performs a loading of all installed peristaltic pumps - can be used to fill the circuit of detergents in case of first installation or to check the proper functioning of the peristaltic (detergents) pumps. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG GW6010MP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG GW6010MP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag