User manual SMEG KS98XSE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG KS98XSE. We hope that this SMEG KS98XSE user guide will be useful to you.

Lastmanuals help download the user guide SMEG KS98XSE.


Mode d'emploi SMEG KS98XSE
Download
Manual abstract: user guide SMEG KS98XSE

Detailed instructions for use are in the User's Guide.

[. . . ] The fat accumulated in the filters may drip or catch fire when the temperature increases. Avoid cooking under the kitchen hood if the metal filters are not fitted, e. g. : while they are being cleaned in the dishwasher. You must not produce flames under the kitchen hood. Do not place anything on top of the cooker hood. [. . . ] Disconnect the appliance before any interior manipulation, e. g. We recommend the use of gloves and to be extremely careful when cleaning the kitchen hood's interior. Your kitchen hood is designed for domestic use and only for extraction and purification of fumes produced during food preparation. It will be your responsibility if it is used for other purposes, which may be dangerous. The manufacturer cannot accept responsibility for damage caused by improper use of the appliance. For repairs please contact the nearest SMEG Technical Assistance Service, and always use genuine spare parts. Repairs or modifications carried out by unqualified personnel can cause malfunctions or may damage the appliance, putting your safety in danger. This appliance is marked according to the European directive 2002/96/EC on "Waste Electrical and Electronic Equipment" (WEEE). This guideline is the frame of a European-wide validity of return and recycling on Waste Electrical and Electronic Equipment, and it is symbolized by: . When the cooker hood is on at the same time as other appliance or equipment with different energy source, the air extraction (underpressure) must no be higher than 4Pa (4 x 10-5 bar). · Fit the metal filters. _________________________________________________________ Proceed with the following checks before calling the Technical Service: Problem solving GB See page 39. Sizes and specifications 16 SMEG reserves the right to make changes and corrections to its products as it deems necessary, without altering their basic characteristics. Accesories supplied 1 1 2 4 4 4 2 6 2 2 150/ 120 mm reduction. Anti-recoil valve. the tubecovers. 9) Fit the clips (F) to the support (C). 10) Centre the support (C) around the shape marked; trace and drill the fixing points for the wall plugs (E) (Ø6 x 30). Attach the support (C) with the long bolts (D) (Ø4 x 30). 12) Attach the inner tube with a clamp (not supplied) to (B) or on to the motor's air outlet vent as the case may be. 11) Fit the part (B) if the inner tube (not supplied) is Ø120. Installation Fig. 1 (Page 39) On installing the kitchen hood make sure that the Safety Instructions set out on page 14 are complied with. To obtain optimum performance, the external conduct must not be more than FOUR METRES long, have no more than two 90° angles and its diameter must be at least Ø120. 13) Once the inner tube is fitted, fit the lower tubecover around the extractor fan outlet and attach the upper tubecover with the screws (G) (Ø3, 9 x 19). The active charcoal filters have an active life of three to six months, depending on the individual conditions of use. These filters 1) Trace and drill the points for fitting the wall cannot be washed nor regenerated. They must plugs onto the wall (A1) (Ø8 x 40). See figure be replaced once their useful life comes to an nr. 2) Fit the wall plugs (A1) and screw in the long bolts (A2) (Ø5 x 45) leaving them protruding 5 Fig. [. . . ] See figure be replaced once their useful life comes to an nr. 2) Fit the wall plugs (A1) and screw in the long bolts (A2) (Ø5 x 45) leaving them protruding 5 Fig. 1) Put the filters into the lateral draught section 3) Attach the kitchen hood to the long bolts of the motor making the holes in the filters (A2). Straighten the apparatus and tighten the match up (A) with the pivots (B) of the motor long bolts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG KS98XSE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG KS98XSE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag