User manual SMEG PNL64ES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG PNL64ES. We hope that this SMEG PNL64ES user guide will be useful to you.

Lastmanuals help download the user guide SMEG PNL64ES.


Mode d'emploi SMEG PNL64ES
Download
Manual abstract: user guide SMEG PNL64ES

Detailed instructions for use are in the User's Guide.

[. . . ] THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE. DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE. IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES. THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. [. . . ] The distances in the following drawing refer to the hole on the inner side of the gasket. The diagram below shows the exact positions of the holes to be used for clamping the hob to the top correctly. 21 Instructions for the installer 3. Electrical connection Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. Pass the power supply cable through the back of the unit, taking care that it does not touch the bottom casing of the hob or the oven (if any) installed underneath it. On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts. If the power cable is replaced, the wire section on the new cable must not be less than 0. 75 mm2 (3 x 0. 75 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green The power lead must be changed by the manufacturer or by an authorised service centre to prevent any risks. The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob. 22 Instructions for the installer 4. Gas connection If the appliance is installed on an oven, the gas pipe must not be passed along the back of the oven, as this may cause overheating. Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force. On some models, for easier connection the union A on the back of the appliance can be adjusted sideways. The torque wrench setting of the nozzle must not exceed 3 Nm. Regulate the air by sliding regulator D until reaching distance "X" shown in the table in paragraph "5. 4 Regulation of primary air ". Lock regulator D by tightening screw C. Burner Rated heating capacity (kW) Nozzle diameter 1/100 mm 48 62 75 82 76 48 LPG ­ G30/G31 28/37 mbar Auxiliary Semi rapid Medium rapid Large rapid UR A B 1. 0 1. 6 2. 3 3. 0 3. 6 By-pass mm 1/100 30(**) 30 (*) 30(**) 33 (*) 40(**) 40 (*) 40(**) 45 (*) 48 (**) 50 (*) Reduced flowrate (W) 450 500 700 800 1000 Flowrate g/h G30 73 116 167 218 261 Flowrate g/h G31 72 114 164 215 257 */**: diameters marked * and ** must be fitted respectively on valves marked * and **shown inpoint "5. 6 Regulation of minimum for natural gas". CAUTION: for references A and B on the lh UR and rh UR burners, see drawings at side. 5. 3 Regulation for natural gas The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. If the problem persists after this cleaning, contact an authorised service centre. 5. 9 Lubrication of gas taps After a while, the gas tap may become hard to turn or lock. If this happens, it has to be cleaned inside and re-greased. This must be done by a qualified technician. 28 Instructions for the user 6. Description of controls 6. 1 Front control panel MODEL 60 CONTROL PANEL All of the commands and controls for the hob are found on the front panel. MODEL 70 CONTROL PANEL MODEL 100 CONTROL PANEL DESCRIPTION OF THE KNOB The flame is lit by pressing the knob and simultaneously turning it anticlockwise to the minimum flame symbol . To adjust the flame, turn the knob to the zone between maximum minimum . Turn off the flame by turning the knob to position . and ARRANGEMENT OF BURNERS ­ Description of symbols REAR RIGHT (REAR LEFT ON 100 CM. MOD. ) REAR LEFT (REAR RIGHT ON 100 CM. [. . . ] 8. 2. 2 Grids and burner caps In normal use of the hob, the grids and burner caps normally get browned as a result of the high temperature. For optimum cleaning remove the burner cap and lift up one of the horizontal spokes of the grid to remove it from its housing. Clean these details with a fine abrasive sponge or similar products found on the market. Then redo with specific polish to make the steel shiny. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG PNL64ES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG PNL64ES will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag