User manual SMEG S1MEB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG S1MEB. We hope that this SMEG S1MEB user guide will be useful to you.

Lastmanuals help download the user guide SMEG S1MEB.


Mode d'emploi SMEG S1MEB
Download
Manual abstract: user guide SMEG S1MEB

Detailed instructions for use are in the User's Guide.

[. . . ] POSITIONING, HOOKUP, COMMISSIONING, TROUBLESHOOTING AND REPLACING POWER CABLES MUST ALWAYS BE DONE BY QUALIFIED PERSONS. CHANGES IN THE POWER VOLTAGE OF MORE THAN 10% OF THE RATED VALUE CAN DAMAGE THE ELECTRICAL CIRCUITS; MONITOR THE MAINS VOLTAGE CONSTANTLY. THE APPLIANCE MUST BE GROUNDED AS REQUIRED BY ELECTRICAL EQUIPMENT SAFETY STANDARDS. THIS UNIT IS INTENDED ONLY FOR THE INTENDED PURPOSE OF TREATING WATER FOR TECHNICAL PURPOSES. SHIPPING/DELIVERY: THERE ARE NO SPECIAL PRECAUTIONS FOR UNPACKING THE APPLIANCE, EXCEPT FOR THE NORMAL CARE REQUIRED IN HANDLING FRAGILE MATERIALS. BEFORE DISPOSING OF THE PACKAGING, MAKE SURE IT DOES NOT CONTAIN ANY PARTS, INSTRUCTION BOOKLET OR OTHER DOCUMENTATION. THE PACKAGING (CARDBOARD, EXPANDED POLYSTYRENE, PALLET, ETC. ) MUST NOT BE LEFT WITHIN THE REACH OF CHILDREN, SINCE THEY ARE HAZARDOUS MATERIALS. THE OSMOSIS TREATMENT UNIT MAY BE REMOVED FROM ITS ORIGINAL POSITION ONLY BY SPECIALISED PERSONS. [. . . ] WHEN CLEANING THE APPLIANCE DO NOT USE CORROSIVE PRODUCTS, ACIDS, STEEL PADS OR BRUSHES. DO NOT WASH THE APPLIANCE WITH DIRECT OR HIGH PRESSURE JETS OF WATER. THE MANUFACTURER DECLINES ALL LIABILITY FOR INJURY/DAMAGE TO PERSONS OR PROPERTY CAUSED BY NON-OBSERVANCE OF THE INSTRUCTIONS GIVEN IN THIS MANUAL, INCORRECT USE, TAMPERING BY UNQUALIFIED PERSONS, TAMPERING WITH EVEN ONE PART OF THE APPLIANCE, OR THE USE OF NON-ORIGINAL SPARE PARTS, OR MODIFICATIONS, ACCESSORIES OR DEVICES OF ANY KIND APPLIED TO THE APPLIANCE UNLESS EXPRESSLY SPECIFIED IN THIS MANUAL. - 30 - THIS APPLIANCE IS MARKED AS REQUIRED BY EU DIRECTIVE 2002/96/EC, WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEE). BY MAKING SURE THAT THIS PRODUCT IS DISPOSED OF CORRECTLY THE USER HELPS TO PREVENT POTENTIAL DETRIMENTAL EFFECTS ON HEALTH AND THE ENVIRONMENT. THE SYMBOL ON THE PRODUCT OR IN THE TECHNICAL DOCUMENTATION INDICATES THAT THIS PRODUCT MUST NOT BE TREATED AS ORDINARY DOMESTIC WASTE BUT MUST BE CONSIGNED TO THE SPECIAL COLLECTION POINT FOR THE RECYCLING OF ELECTRICAL AND ELECTRONIC EQUIPMENT. WHEN DECOMMISSIONING THE APPLIANCE COMPLY WITH THE LOCAL WASTE DISPOSAL REGULATIONS. FOR FURTHER INFORMATION ON THE TREATMENT, RECOVERY AND RECYCLING OF THIS PRODUCT, CONTACT THE COMPETENT LOCAL OFFICE, THE DOMESTIC WASTE COLLECTION SERVICE, OR THE SHOP WHERE THE PRODUCT WAS PURCHASED. FOR ANY TECHNICAL OR OPERATIONAL INFORMATON, PLEASE CONTACT OUR TECHNICAL SERVICE DEPARTMENT. IMPORTANT: DURING THE WARRANTY PERIOD THE MACHINE MAY NOT BE WORKED ON WITHOUT ADVANCE AUTHORISATION FROM OUR TECHNBICAL SERVICE DEPARTMENT. FAILURE TO ABIDE BY THIS RULE VOIDS THE WARRANTY. 2. Technical characteristics GENERAL DESCRIPTION: THE APPLIANCE PRODUCES OSMOSIS- TREATED WATER, WITHOUT DISSOLVED SALTS, WITH A RESIDUAL CONDUCTIVITY IN THE RANGE 20 TO 100 MICROSIEMENS, INTENDED EXCLUSIVELY FOR TECHNOLOGICAL APPLICATIONS. THE UNIT CONSISTS OF AN ARRAY OF FILTER CARTRIDGES. IMPORTANT Replace the pre-filter every 3000 hours of operation and AT LEAST 1 time a year. Pre-filter Replacing the pre-filter: Filter cartridge replacement procedure - Shut off power; - Close the side cocks (RL); - Vent the circuit from the top cap (S); - Unscrew the filter housing (use the special wrench supplied in the accessories bag). Place a container to drain the water in the filter into; - Fit the new cartridge and check it is correctly seated; - Close vent S and open the side cocks RL; - Check for leaks and water in the bottom of the appliance; - Dry it off thoroughly. Membrane Replacing the membranes: Cartridge replacement procedure. - Shut off power; - Disconnect all hoses from the membrane housings, unscrew the base, and place a container to catch the water contained in the cartridges; - Refit the membrane, check the seating of the o-ring and screw the housing fully in; reconnect the hoses and make sure they are correctly seated; - Do not apply excessive force; - Fit the new cartridge and check it is correctly seated; - Start the unit up and check for leaks. - 36 - Special adjustments: RECIRCULATION Recirculation retreats the waste water to reduce the amount of water rejected. Turn the needle valve "Recirculation" to retreat the waste water, thus reducing overall water consumption. Important! Make sure, when making adjustments, that the pressure gauge reading never exceeds 10-11 bar. BYPASS Turn the "Bypass" needle valve to adjust the conductivity of the osmosis-treated water, at the expense of the hourly water production and the amount of water rejected. NOTE: In both cases, before setting the needle valves you must slacken off their collars and tighten them down after the adjustment has been made. Recirculation Bypass Collar Inactivity: There are no special warnings regarding maintaining the appliance's operability when kept inactive for short periods of time. For long periods of inactivity contact your local Authorised Reseller so that he can remove and store the inverse osmosis membranes and also restart the unit after recommissioning as for the first installation. - 37 - 5. Plumbing diagram - 38 - LEGEND HYDRAULIC DIAGRAM IN E1 P1 FIL M1 SR VR MP SM MO CO Water inlet Filler solenoid valve Filler pressure switch Filter - CARBONLOK 5 micron Osmosis pump "Re-treatment" needle valve Non-return valve Pump pressure gauge Mixer needle valve Osmosis membrane Conductivity meter F1 P2 R M2 F2 E2 SS VE P3 SC PR Product flow meter Delivery minimum pressure switch Vat cock Delivery pump Waste flow meter Discharge solenoid valve Discharge choke Espansion tank Delivery pressure switch Water discarded Produced water LEGEND ELECTRIC DIAGRAM SA CO LR LV SE M2 P3 P2 SS IR Anti flooding sensor Conductivity meter Red led Green led Electronic board Delivery pump Delivery pressure switch Delivery minimum pressure switch Shuko plug Delivery switch IO E1 E2 M1 LB LA PB F2 SE F1 Osmosis switch Filler solenoid valve Discharge solenoid valve Osmosis pump Low level switch High level switch Low pressure switch Waste flow meter Selector Product flow meter - 39 - 6. Wiring diagram - 40 - Electrical specifications: Power supply: 230v AC 50/60Hz Max motor outlet load: 16A_ at 230V AC Max load on solenoid valve 1 outlet: 1A_ at 230v AC Max load on solenoid valve 2 outlet: 1A_ at 230V AC Instrumentation: Conductivity meter (normalised at 20°C ) scale: 0-200uS/cm with probe K=5. Class (overall): 1 Calibrated by samples. Switchable display of uS/cm and mg/l; simply press the down button during operation. [. . . ] Switchable display of uS/cm and mg/l; simply press the down button during operation. Flow meter: pulses/l given by sensor: programmable (to account for laminar and lamellar water flow). Just one flow meter is provided, which can be switched to read a second flow (simultaneous reading: not possible). HOOK UP J2 GREEN POWER LED (RES 390) + - HOOK UP J4 RED ALARM LED (RES 390) + - MAX PRESS. ALARM TRIPS WHEN IT CLOSES CONDUCTI VITY METER CELL INPUT, FLOODING AND MAX PRESSURE Minimum pressure switch High level Low level Flow meter switch Flow meter Inputs: high level, low level, flow meter switch, minimum pressure switch: inputs receive only voltage-free contacts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG S1MEB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG S1MEB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag