User manual SMEG VI144P1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG VI144P1. We hope that this SMEG VI144P1 user guide will be useful to you.

Lastmanuals help download the user guide SMEG VI144P1.


Mode d'emploi SMEG VI144P1
Download
Manual abstract: user guide SMEG VI144P1

Detailed instructions for use are in the User's Guide.

[. . . ] After inserting the sterilization package switch on transport. The sterilization package is then transported and the area of the sealing seam is heated to the sealing temperature set on the upper and lower heating dies. The hot seam is pressed together by the sealing roller sealing it. The printing operation is activated and the activated print data is printed onto the sealed package. [. . . ] The printing operation is activated and the activated print data is printed onto the sealed package. The finished sterilization package is transported to the discharge side. If more packages to be sealed are not fed in the transport mechanism shuts off after approx. 30 s. GB 4 9. 696. 038 ENGLISH VI144P1 Before Starting 3 General safety instructions I The device must not be installed or operated by persons under 14 years of age. The device must not be operated unattendedly. Turn of the device or disconnect the power cord when it is not in use. The device should only be cleaned with a dry or slightly damp cloth. Never clean the device wet! Installation I I Do not install or operate the machine in explosion hazard areas. Use only power sockets with protective ground. Heavy dust, vapor, dripping or spraying water have a negative effect on the machine functions. F Always ensure that the operating power corresponds to the specifications on the machine rating plate. Please choose a socket where the line power is stable. Please do not transport device on the peel edge setting! Œ • Leave a gap of 200 mm between the device and the wall. 200 mm • Œ GB 5 9. 696. 038 ENGLISH VI144P1 Before Starting 3 Start-Up l Plug power cable into power socket on machine l Insert plug into wall socket l Switch on machine with power switch Power switch Switch connection FUNCTION Machine switched on Self-test runs for approx. 30 s Default settings When the device is switched on for the very first time, the following defaults must be undertaken: Language also refer to page 8 DISPLAY Please wait set Language D Unit of measure EU dd-mm-yy hh. mm 10-03-08 09:30 Control VI144P1 V069. 27 440001 Acknowledge maintenance message Measurement unit also refer to page 8 Date and time also refer to page 9 Display for approx. This ensures the correct contact pressure for the guide rail. l Close housing Distance between screw head and rail = 1 mm Œ • Œ • Œ Ž PTFE strip Ž GB 20 9. 696. 038 ENGLISH VI144P1 Troubleshooting and Maintenance 5 Maintenance Information Please use only genuine replacement parts. Replacing Teflon strip for upper and lower heating die l Switch off machine and DISCONNET POWER PLUG !l Open housing l Remove mounting screws Œ for upper guide rail and remove guide rail. ! Œ l Disconnect electrical connections for heating die l Remove fastening srew bottom• Remove top or bottom heating die PTFE strip • and at the Œ l l Unscrew mounting screw ‘ and detach l Remove backing foil on new PTFE strip and glue new Teflon strip on straight and without wrinkles l Fasten PTFE strip with screw ‘ l Install heating die l Fasten fastening screws • + • of the heating die l Reconnect electrical connections to heating die • • l Detach nuts ’ l Set distance between the sealing dies to 0. 5 mm ’ ‘ ‘ l Fasten nuts ’ l Install guide rails. 0, 5 mm FWhen installing the upper guide rail before fastening , push the die down so that the interval between the srew head and rail is 1mm on both sides. This ensures the correct contact pressure for the guide rail ‘ ‘ Distance between screw head and rail = 1mm l Close housing 9. 696. 038 GB 21 ENGLISH VI144P1 Troubleshooting and Maintenance 5 Maintenance Information Replacing pressure roller !Please use only genuine replacement parts. l Switch off machine and DISCONNET POWER PLUG !l Open housing l Remove mounting screws Œ for upper guide rail and remove guide rail. l Unscrew pressure adjustment screw • approx. 5 mm l Loosen mounting screw Ž and pull pressure roller completely out of holder l Detach snap ring • and remove pressure roller l Install new pressure roller and fasten with snap ring • l Position complete pressure roller in holder, center in relation to bottom roller and tighten mounting screw Ž l Adjust contact pressure by screwing in adjustment screw •according to calibration instructions on page 24 • Ž Œ Œ • Œ l Install guide rail FWhen installing the upper guide rail before fastening, push the die down so that the interval between the screw head and rail is 1 mm on both sides. This ensures the correct contact pressure for the guide rail. Distance between screw head and rail = 1 mm l Close housing GB 22 9. 696. 038 ENGLISH VI144P1 Troubleshooting and Maintenance 5 Calibration After replacing the temperature sensor or heating elements it is necessary to calibrate the temperature. After replacing the print head or "print start" light barrier it is necessary to calibrate the printer. After replacing the electronic unit it is necessary to perform both adjustment operations. F Only possible with Service Dongle. [. . . ] 5 mm l Loosen mounting screw Ž and pull pressure roller completely out of holder l Detach snap ring • and remove pressure roller l Install new pressure roller and fasten with snap ring • l Position complete pressure roller in holder, center in relation to bottom roller and tighten mounting screw Ž l Adjust contact pressure by screwing in adjustment screw •according to calibration instructions on page 24 • Ž Œ Œ • Œ l Install guide rail FWhen installing the upper guide rail before fastening, push the die down so that the interval between the screw head and rail is 1 mm on both sides. This ensures the correct contact pressure for the guide rail. Distance between screw head and rail = 1 mm l Close housing GB 22 9. 696. 038 ENGLISH VI144P1 Troubleshooting and Maintenance 5 Calibration After replacing the temperature sensor or heating elements it is necessary to calibrate the temperature. After replacing the print head or "print start" light barrier it is necessary to calibrate the printer. After replacing the electronic unit it is necessary to perform both adjustment operations. F Only possible with Service Dongle. The Service Dongle is located in the device, left of the Control card FUNCTION Switch off machine Switch on machine Self-test runs for approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG VI144P1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG VI144P1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag