User manual STANDARD HORIZON DS41

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual STANDARD HORIZON DS41. We hope that this STANDARD HORIZON DS41 user guide will be useful to you.

Lastmanuals help download the user guide STANDARD HORIZON DS41.


Mode d'emploi STANDARD HORIZON DS41
Download
Manual abstract: user guide STANDARD HORIZON DS41

Detailed instructions for use are in the User's Guide.

[. . . ] DS41 Digital Depth Sounder Owner'sManual Standard 2 Inch Installation Dual Station Operation NMEA Repeater Reads in Feet Fathoms or Meters Adjustable Prop or Surface Offset Shallow and Deep alarms Du Sta al Ope tion rati on Contents Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarms On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Use the " and # keys to change the value. To exit this mode, press and hold both the " and # keys simultaneously. Alternatively, if no keys are pressed for a period of 5 seconds normal depth display will resume. ^ V OFF Press simultaneously The display will now indicate the current water depth in the selected display unit. DS41 Owner's Manual 5 Troubleshooting No display: 1. Check DC power connections and DC polarity with voltmeter. No depth reading (## at all depths: ##) ## 1. Check transducer for growth or multiple coats of paint. Check the transducer cable for cuts and sharp bends. Check that the transducer connection behind the D41is firm and free of corrosion. Erratic readings while moored: Check transducer for growth or multiple coats of paint. Erratic readings while moving: Cavitation (air) under the face of the transducer. Review installation and reinstall if necessary. Erratic readings only while engine is running: 1. Re-route power and transducer cables away from engine, ignition wires and battery cables. Add feed-through filter capacitor on the positive terminal of the ignition coil. Add an alternator whine filter to alternator. When selecting the location for mounting, the following are recommended: · · Controls of the instrument must be accessible to the user. Electrical connections must be routed to the boat system as directly as possible, minimising the length of cable where practical. 2. Drill a 2-inch hole on the instrument panel in the selected location. With the mounting bracket removed, insert the instrument into the hole until the back of the face plate is flush with the outside mounting wall. Slide the bracket over the body of the instrument. Note: Orient the bracket in such a manner that it does not cover the buzzer. 5. Tighten the mounting nut until the bracket is secure. 2. 5" 2. 5" 2. 5" INTERCHANGEABLE FACE PLATES ROUND FACE PLATE SQUARE FACE PLATE . 75" . 5" 3. 75" Figure 1. Depth Sounder Dimensions DS41 Owner's Manual 9 6. [. . . ] Continue to hold the # key until the display indicates the current master/slave selection. 8 Ft Master Slave example Note: The instrument designated as the master device is the only instrument connected to the depth transducer. See the Wiring Connection section for dual station wiring details. Also see the Instrument Setup section for configuration details. 4. Use the " and # keys to change the selection. To exit this mode, press and hold both the " and # keys simultaneously. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE STANDARD HORIZON DS41

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual STANDARD HORIZON DS41 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag