User manual SUB-ZERO 36GASRANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO 36GASRANGE. We hope that this SUB-ZERO 36GASRANGE user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO 36GASRANGE.


Mode d'emploi SUB-ZERO 36GASRANGE
Download
Manual abstract: user guide SUB-ZERO 36GASRANGE

Detailed instructions for use are in the User's Guide.

[. . . ] Planning Information 36" (914) Gas Ranges MODELS R366 / R364C / R364G Porcelain-coated cast iron top grates Model R366 5" (127) riser (optional) Infrared griddle (optional) Dual brass burners Model R364C Location of rating plate Burner drip pan Oven light switch Model R364G Large red control knobs Convection fan switch Pull-out drip tray Large-capacity convection oven Oven indicator light Three adjustable oven racks Griddle indicator light Stainless steel exterior finish Model R364G shown with 5" (127) riser Full side panels and skirt The Wolf 36" (914) gas range is available in natural or LP gas, with your choice of three top configurations. Model numbers indicate the features; (C) charbroiler and (G) griddle. The model number followed by (-LP) denotes an LP gas model. If it looks as if it could be in a restaurant kitchen, well, that's natural. [. . . ] IMPORTANT NOTE: A minimum 5" (127) riser is required when installing a gas range against a combustible surface. A minimum 10" (254) riser is required when installing a gas range with a charbroiler or griddle against a combustible surface. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information 36" (914) Gas Ranges MODELS R366 / R364C / R364G I N S TA L L AT I O N S P E C I F I C AT I O N S VENTILATION HOOD 30"min (762) COUNTERTOP TO COMBUSTIBLE MATERIALS 36"min (914) 30"(762) TO 36"(914) 6" min (152) TO COMBUSTIBLE MATERIALS (BOTH SIDES) FOR CHARBROILER COUNTERTOP TO BOTTOM OF VENTILATION HOOD 13" max (330) 18"min (457) TO COUNTERTOP 361/4" (921) FINISHED ROUGH OPENING WIDTH 36" (914) 10" (254) 12" (305) 37" (940) TO COOKING SURFACE 8" (203) E 2" (51) 51/2" (140) G 12" (305) 5" (127) LOCATION OF GAS SUPPLY EXTENDS 3" (76) ON FLOOR FROM BACK WALL 3" (76) ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP ­ 0" (0) TO NON-COMBUSTIBLE MATERIALS DIMENSIONS Overall Width of Range Finished Rough Opening Width Location of Gas Supply Location of Electrical See Installation Instructions shipped with unit for detailed specifications. Refer to the Wolf Design Guide for additional specifications. 36" (914) 36 1/4" (921) Within shaded area Within shaded area Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information 36" (914) Gas Ranges MODELS R366 / R364C / R364G I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf gas range to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Please follow the minimum clearances established in the finished rough opening dimensions as shown in the Installation illustration. IMPORTANT NOTE: A minimum 5" (127) riser is required when installing a gas range against a combustible surface. A minimum 10" (254) riser is required when installing a gas range with a charbroiler or griddle against a combustible surface. It is recommended that you use a Wolf Pro wall or island ventilation hood or hood liner with the Wolf gas range. Pro Ventilation information can be found on our website, wolfappliance. com. Also refer to the Wolf Design Guide for Pro ventilation recommendations. The Wolf gas range requires a 110 /120 V AC, 60 Hz electrical supply to operate the electronic ignition system. The 6' (1. 8 m) power supply cord provided with the range is equipped with a 3-prong, grounded plug for protection against shock hazard. The service should have its own 15 amp circuit breaker. Locate electrical and gas supply within the shaded area shown in the Installation illustration. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Wolf gas ranges are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. [. . . ] You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services. Refer to the installation instructions shipped with each Wolf product for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 5 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 36GASRANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 36GASRANGE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag