User manual SUB-ZERO DD30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO DD30. We hope that this SUB-ZERO DD30 user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO DD30.


Mode d'emploi SUB-ZERO DD30
Download
Manual abstract: user guide SUB-ZERO DD30

Detailed instructions for use are in the User's Guide.

[. . . ] To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. C O U N T E R T O P C U T- O U T 23/4" (70) 27" (686) 251/8" MIN (638) FLAT COUNTERTOP SPACE COOKTOP CUT-OUT WIDTH 191/4" (489) 21/2" MIN (64) Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Models DD30 I and DD30R Downdraft Systems 13/4" MIN (45) BACK EDGE OF COOKTOP TO INSIDE OF CABINET BACK* . 344" 251/8" MIN (638) OF FLAT COUNTERTOP* 5/8" (16) 191/4" (489) COOKTOP CUT-OUT DEPTH 21/2" MIN (64) WITH NO RAISED LIP* 23/8" (60) 21/8" (54) 31/4" 295/16" (745) COUNTERTOP TO BOTTOM OF AIR BOX (83) 711/16" (197) 35/8" (92) 36" (914) 5" (127) 18" (457) 71/8" (181) 24" MIN (610) CABINET DEPTH *AREAS OF POTENTIAL INTERFERENCE L O C AT I O N O F E L E C T R I C A L 4"min (102) 24 " min (610) CABINET DEPTH 3 1/2" (89) E 10" (254) E ELECTRICAL LOCATION IN CABINET BACK 30"min (762) OPTIONAL ELECTRICAL LOCATION IN ADJACENT RIGHT SIDE CABINET DIMENSIONS Downdraft Cut-Out Width Recommended Cabinet Width Downdraft Cut-Out Depth Location of Electrical See Installation Instructions shipped with unit for detailed specifications. 27" (686) 33" (838) 2 3/4" (70) Within shaded area Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Models DD30 I and DD30R Downdraft Systems I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf downdraft ventilation systems are recommended for use with Wolf electric and gas cooktops and integrated modules, excluding the grill, steamer and fryer modules. The downdraft should be at least as wide as the cooking surface. IMPORTANT NOTE: Wolf downdraft ventilation systems cannot be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops. [. . . ] IMPORTANT NOTE: Install this downdraft only with a Wolf blower. Wolf downdraft ventilation systems require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the 2' (. 6 m) power cord. The specific location of the outlet is not critical, as long as it is within reach of the power cord that is located mid-way, top and bottom on the right side of the downdraft. If the 30" (762) downdraft is being installed in a 30" (762) wide cabinet, the outlet cannot be located on the back wall of the cabinet. It is recommended that the outlet be placed in an adjacent cabinet within reach of the power cord. Refer to the Location of Electrical illustration on page 4. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. This appliance must be used with a Wolf approved remote mounted control module and top cover, which is included in the downdraft control kit, available as a sales accessory. Installation of the control module must be within 10' (3 m) of the downdraft assembly and a minimum of 4" (102) from the outer edge of cooktop element or burner. You will be required to drill three holes and connect the two units by the provided wire. If a 30" (762) downdraft is installed in combination with two integrated modules, an integrated module support for downdraft ventilation (ISUPPORT) is required. Refer to the installation instructions shipped with each Wolf product for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Models DD30 I and DD30R Downdraft Systems D U C T I N G C O N S I D E R AT I O N S Except for Models DD30I, DD36I and DD45I, which include a 500 CFM internal blower, Wolf downdrafts are shipped without the blower assembly. In-line and remote blower assemblies are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. IMPORTANT NOTE: Install this downdraft ventilation system only with a Wolf blower. Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles. Three different discharge locations are available with side to side adjustment for accurate alignment of ductwork. Refer to the illustration below for discharge location options. Discharge location options for internal and remote blower models. CENTERLINE OF COUNTERTOP CUTOUT 163/8" (416) INTERNAL BLOWER 211/2" (546) REMOTE BLOWER CL 221/8" (562) INTERNAL BLOWER 19" (483) REMOTE BLOWER RIGHT DISCHARGE LOCATION LEFT DISCHARGE LOCATION 51/2" (140) INTERNAL BLOWER 41/4" (108) REMOTE BLOWER DISCHARGE CUTOUT DIMENSIONS: 101/4" (260) x 31/2" (89) INTERNAL BLOWER 141/4" (362) x 31/2" (89) CENTERLINE OF COUNTERTOP CUTOUT REMOTE BLOWER CL ADJUSTMENT: 1" (25) - 7" (178) INTERNAL BLOWER 21/2" MAX (165) REMOTE BLOWER ADJUSTMENT: 5" MAX (127) REMOTE BLOWER BOTTOM DISCHARGE LOCATION 51/2" (140) INTERNAL BLOWER 41/4" (108) REMOTE BLOWER NOTE: Measurements are to centerline of duct cutouts Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Models DD30 I and DD30R Downdraft Systems D U C T I N G C O N S I D E R AT I O N S For best performance, 10" (254) round ductwork is recommended. The downdraft will operate most efficiently when ductwork does not exceed 40' (12 m) in length. [. . . ] In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers. (83) x 10" (254) duct for internal blower, no transition required. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO DD30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO DD30 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag