User manual SUUNTO D3 QUICK GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO D3. We hope that this SUUNTO D3 user guide will be useful to you.

Lastmanuals help download the user guide SUUNTO D3.


Mode d'emploi SUUNTO D3
Download
Manual abstract: user guide SUUNTO D3QUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] EN USER'S GUIDE Present Depth Maximum Depth Average Depth in Logbook Fast Ascent Warning (SLOW) AC Indicator Current Time Display Surface Interval Time Bar Graph: - Mode Indicator Data Transfer AVG MAX m ft Bar Graph: - Ascent Rate - Battery Power - Mode Indicator SURF TIME MAX O2% AM/PM Indicator FREE Temperature Maximum Depth Mode Text Oxygen Percentage in Nitrox Mode Week Day Timer Hours and Minutes AS C Diver Attention Symbol DIVE TIMER PO2 ft m °F °C Dive Time Dive Counter Time Dual Time Day, Month Timer Seconds Downtimer Daily Alarm On Indicator Dive Alarm On Indicator Low Battery Warning SUUNTO QUICK REFERENCE GUIDE DEFINITION OF WARNINGS, CAUTIONS AND NOTES Throughout this manual, special references are made when deemed important. Three classifications are used to separate these references by their order of importance. WARNING - is used in connection with a procedure or situation that may result in serious injury or death. CAUTION - is used in connection with a procedure or situation that will result in damage to the product. [. . . ] When the daily -symbol blinks for 1 minute alarm activates, the and the alarm sounds for 24 seconds. The alarm is given at the preset time each day. Press any button to stop the audible alarm, after it has activated. In the Setting Mode, press S two (2) times to select the Daily alarm Setting Mode (Fig. Wait two seconds until the Daily Alarm Setting Mode activates automatically. The time mode indicator appears and the alarm status [On/OFF] starts to blink on the display (Fig. Daily Alarm Setting Mode is activated. AS C AS C 39 3. Press S to change the selection in the following sequence: ->On/OFF status -> hours -> minutes 4. While the alarm status [On/OFF] is selected (blinking) press + or - to change the status. When the alarm status is On, the daily alarm indicator ( -symbol) in the bottom right corner of the display indicates that the alarm is on. Set the other sections as follows: · While any other digits (except alarm status) are selected (blinking), press + to increase the value or - to decrease it. Holding down either button starts the scrolling of the current selection. · The 12-hour or 24-hour format of the alarm matches the format of the timekeeping display, which is selected in the Time Adjustment Mode (see chapter 4. 1. ). When using the 12-hour format of the alarm, take care to set the time correctly as morning (AM) or afternoon (PM). After you have set the daily alarm, press the M button to save the settings and to return to the Setting Mode [SET]. 40 4. 3. TIMER SETTINGS [TIMER D] In this mode you can set the countdown time for the downtimer. The downtimer also has an alarm repeat function for continuous downtimer alarm. To set the downtimer: 1. In the Setting Mode, press S three (3) times to select the Timer Setting Mode (Fig. 4. 8. ) 2. Wait two seconds until the Timer Setting Mode activates automatically. The SET mode and DT segments are displayed. 3. Press S to change the selection in the following sequence: -> minutes -> seconds -> alarm repeat When the minutes and seconds are selected (blinking), press - to decrease and + to increase the value. After the downtimer time selection, the downtimer alarm repeat is selected. [. . . ] The maximum amount of time a diver may remain at a particular depth without having to make decompression stops during the subsequent ascent. No-decompression time O2% Oxygen percentage or oxygen fraction in the breathing gas. Limits the maximum depth to which the used Nitrox mixture can safely be used. The maximum partial pressure limit for enriched air diving is 1. 4 bar. The contingency partial pressure limit is 1. 6 bar. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO D3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO D3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag