User manual SUUNTO FAVOR LUX QUICK GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO FAVOR LUX. We hope that this SUUNTO FAVOR LUX user guide will be useful to you.

Lastmanuals help download the user guide SUUNTO FAVOR LUX.


Mode d'emploi SUUNTO FAVOR LUX
Download
Manual abstract: user guide SUUNTO FAVOR LUXQUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] 2 COPYRIGHT, TRADEMARK AND PATENT NOTICE This instruction manual is copyrighted and all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any media without prior written consent from SUUNTO. SUUNTO, FAVOR, FAVOR LUX, FAVOR LUX S, FUSION, FUSION LUX S, OCTOPUS and their logos are all registered or unregistered trademarks of SUUNTO. All rights are reserved. CE The CE mark is used to mark conformity with the European Union EMC directive 89/336/EEC. [. . . ] It includes: The time needed to ascend to the ceiling at an ascent rate of 10 m/min [33 ft/min] plus The time needed at the ceiling. The ceiling is the shallowest depth to which you should ascend plus The time needed to reach the surface after the ceiling has been removed. NOTE: Ascent time is not displayed in the Octopus II dive computer (see Figure 3. 16). WARNING! YOUR ACTUAL ASCENT TIME MAY BE LONGER THAN DISPLAYED ON THE DIVE COMPUTER. The ascent time will increase if you: · · · remain at depth ascend slower than 10 m/min [33 ft/min] or make your decompression stop deeper than at the ceiling. These factors will also increase the amount of air required to reach the surface. WARNING! NEVER ASCEND ABOVE THE CEILING!In order to avoid doing so by accident, you should stay slightly below the ceiling. The ceiling zone is the shallowest depth range to which you should ascend when in decompression. 33 C a R A T E CEILING ASC TIME A S m c d A1 MAX DISPLAY BELOW CEILING ZONE The CEILING/ASC TIME symbol and upwards pointing arrow indicate that you are below the ceiling zone (Fig. You should start your ascent immediately. b DIVE TIME LOG HIS ALT SET PLAN DISPLAY AT CEILING ZONE When you reach the ceiling zone, the display will show you two arrows pointing toward each other (the "hour glass" icon, Fig. The two ar rows pointing toward each other will be shown between the minimum ceiling and 1. 8 m [6 ft] below the minimum ceiling. All decompression stops must be performed at or below the ceiling depth range. The depth of the ceiling will depend on your dive prof ile. It will be fairly shallow when you enter the decompression mode, but if you remain at depth, it will move downward and the ascent time will increase. The ceiling depth will be shown on the left side of the center window. Fig 3. 16 OCTOPUS II DECOMPRES-SION DIVE, AT THE CEILING ZONE The two arrows (a) point at each other ("hour glass"). You are at the ceiling zone at 3. 5 m [11 ft] (c) and the ceiling is at 3 m [10 ft] (b). A S C R A T E m CEILING ASC TIME A1 C DIVE TIME LOG HIS ALT SET PLAN Fig. 3. 17 DECOMPRESSION DIVE, ABOVE CEILING Note the downward pointing arrow and the blinking Er warning. You should immediately (within 3 minutes) descend to or below the ceiling. When the sea surface is rough, it may be difficult to maintain a constant depth near the surface. In this case it will be more manageable to maintain an additional distance below to the ceiling, to make sure that the waves do not lift you above the ceiling. SUUNTO recommends that decompression takes place deeper than 4 m [13 ft], even if the indicated ceiling is shallower. NOTE: It will take more time and more air to decompress below the ceiling than at the ceiling. 34 DISPLAY ABOVE CEILING If you ascend above the ceiling, a downward pointing arrow will appear (Fig 3. 17). In addition a blinking error warning Er reminds you that you have only three minutes to correct the situation. You must immediately descend to or below the ceiling. If you continue to violate the decompression requirements, the dive computer goes into a permanent ERROR MODE. 3. 18) you must not dive again for at least two days. [. . . ] No dealer or representation is authorized to make any modifications to this warranty or to make any additional warranty. Battery replacement is not covered by this warranty. This Instruction Manual should be kept with your dive computer. 63 8. GLOSSARY Altitude dive Ascent rate ASC RATE Ascent time ASC TIME Ceiling Ceiling Zone Compartment DCS Decompression Decompression sickness A dive made at an elevation above 700 m [2300 ft] above sea-level. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO FAVOR LUX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO FAVOR LUX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag