User manual SUUNTO MOSQUITO QUICK GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO MOSQUITO. We hope that this SUUNTO MOSQUITO user guide will be useful to you.

Lastmanuals help download the user guide SUUNTO MOSQUITO.


Mode d'emploi SUUNTO MOSQUITO
Download
Manual abstract: user guide SUUNTO MOSQUITOQUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] EN SUUNTO MOSQUITO USER'S GUIDE Present Depth Maximum Depth Average Depth in Logbook Fast Ascent Warning (SLOW) AC Indicator Do Not Fly Icon Current Time Display No-Decompression Time Surface Interval Time No Flying Time Total Ascent Time Ceiling Depth on Decompression Stop Safety Stop Time Mandatory Safety Stop Depth and Time Bar Graph: - Mode Indicator - Oxygen Limit Fraction Altitude Adjustment Mode Personal Adjustment Mode Arrows: - Decompression Stop at the Ceiling Depth - Mandatory Safety Stop Zone - Ascent Recommended - Must Descend Bar Graph: - Ascent Rate - Battery Power - Mode Indicator AM/PM Indicator Safety Stop Warning Safety Stop Indicator Dive Time Dive Counter Oxygen Partial Pressure in Nitrox Mode Time Dual Time Day, Month Timer Seconds Oxygen Partial Pressure Daily Alarm On Indicator Dive Alarm On Indicator Diver Attention Symbol Temperature Maximum Depth Mode Text Oxygen Percentage in Nitrox Mode Week Day Timer Hours and Minutes Low Battery Warning SUUNTO MOSQUITO QUICK REFERENCE QUIDE O LF AS C DEFINITION OF WARNINGS, CAUTIONS AND NOTES Throughout this manual, special references are made when deemed important. Three classifications are used to separate these references by their order of importance. WARNING - is used in connection with a procedure or situation that may result in serious injury or death. CAUTION - is used in connection with a procedure or situation that will result in damage to the product. [. . . ] PERSONAL ADJUSTMENT RANGES 56 3. 2. 5. ERROR CONDITIONS The dive computer has warning indicators that alert the user to react to certain situations that would significantly increased the risk of DCI. If you do not respond to its warnings, the dive computer will enter an Error Mode, indicating that the risk of DCI has greatly increased. If you dive sensibly, it is very unlikely you will ever put the instrument into the Error Mode. OMITTED DECOMPRESSION The Error Mode results from omitted decompression, i. e. when you stay above the ceiling for more than three minutes. During this three-minute period the Er warning is shown and the audible alarm beeps. After this, the dive computer will enter a permanent Error Mode. The instrument will continue to function normally if you descend below the ceiling within this three-minute period. Once in the permanent Error Mode only the Er warning is shown in the center window. The dive computer will not show times for ascent or stops. However, all the other displays will function as before to provide information for ascent. You should immediately ascend to a depth of 3 to 6 m [10 to 20 ft] and remain at this depth until air supply limitations require you to surface. The Error mode will stay for 48 hours, during which time you should not dive. Whilst Mosquito is in Error mode the ASC TIME label will be displayed in the center window and the Planning Mode will be disabled. 57 3. 3. BEFORE DIVING IN THE FREE MODE If set to Free mode, the dive computer can be used for freediving or snorkeling. In the freediving mode the Mosquito provides depth, time and profile information and an accurate 2 second sampling interval for the logbook profile memory The Free mode is set using the SET DIVE function (See Chapter 4. 3 Dive Mode Settings) If set to Free mode the text FREE is shown after activation (Fig. PRESETTING THE DISPLAYS IN THE FREE MODE The information shown in the Free mode can be preset before the dive. Preset with the - button in the lower left corner of the display (Fig. Surface display/ Alternative displays. · · the maximum depth or the temperature. 58 Preset with the + button in the lower right corner of the display (Fig. 3. 28. ) · · · the dive time, the current time or the dive number. 3. 3. 3. DURING THE FREEDIVE In the Freediving mode the present depth is always shown. [. . . ] Oxygen Limit Fraction A term used by SUUNTO for the values displayed in the Oxygen Toxicity bar graph. The value is either the CNS% or the OTU%. O2% Oxygen percentage or oxygen fraction in the breathing gas. Standard air has 21% oxygen. Oxygen partial pressure Limits the maximum depth to which the used Nitrox mixture can safely be used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO MOSQUITO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO MOSQUITO will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag