User manual SUUNTO VYPER AIR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO VYPER AIR. We hope that this SUUNTO VYPER AIR user guide will be useful to you.

Lastmanuals help download the user guide SUUNTO VYPER AIR.


Mode d'emploi SUUNTO VYPER AIR
Download
Manual abstract: user guide SUUNTO VYPER AIR

Detailed instructions for use are in the User's Guide.

[. . . ] EN VYPERAIR USER'S GUIDE Tank Pressure Bar Graph Oxygen percentage (nitrox mode) 1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS . . . . . . . . . . . . . . . . . WARNINGS, CAUTIONS, AND NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUUNTO AT A GLANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When the maximum allowed ascent rate is exceeded, the lower segments start to blink with the top segment staying solid, indicating that the maximum ascent rate has been exceeded continuously or that the current ascent rate is significantly above the allowed rate. ACTIVATED BACKLIGHT, ALARM AND A BLINKING ASCENT RATE BAR GRAPH INDICATE YOU ARE ASCENDING FASTER THAN 10 M/MIN. YOU ARE ADVISED TO MAKE A MANDATORY SAFETY STOP WHEN YOU REACH A DEPTH OF 6 M. NORMAL ASCENT RATE. WARNING DO NOT EXCEED THE MAXIMUM ASCENT RATE!Rapid ascents increase the risk of injury. You should always make the Mandatory and Recommended Safety Stops after you have exceeded the maximum recommended ascent rate. If this Mandatory Safety Stop is not completed, the decompression model will penalize your next dive(s). Continuous ascent rate violations will result in Mandatory Safety Stops. When Recommended Deep Stop is enabled, the length is indicated in seconds. 6. 1. 5. Safety Stops A 3 minute Recommended Safety Stop is prompted after every dive to over 10m. Decompression dives When your NO DEC TIME becomes zero, your dive becomes a decompression dive so you must perform one or more decompression stops on your way to the surface. The NO DEC TIME on your display will be replaced by an ASC TIME, and a CEILING notation will appear. An upward pointing arrow will also prompt you to start your ascent. If you exceed the no-decompression limits on a dive, the dive computer will provide the decompression information required for ascent. After this, the instrument will continue to provide subsequent interval and repetitive dive information. Rather than requiring you to make stops at fixed depths, the dive computer lets you decompress within a range of depths (continuous decompression). The ascent time (ASC TIME) is the minimum amount of time needed to reach the surface in a decompression dive. It includes: · the time needed to ascend to the ceiling at an ascent rate of 10 m/33 ft per minute. The ceiling is the shallowest depth to which you should ascend 31 · · · the time needed at the ceiling the time needed at the Mandatory Safety Stop (if any) the time needed to reach the surface after the mandatory decompression dives have been completed In addition, there may also be Mandatory Safety Stops which are not displayed in ASC TIME. YOUR ACTUAL ASCENT TIME MAY BE LONGER THAN DISPLAYED BY THE INSTRUMENT!The ascent time will increase if you: · remain at depth · ascend slower than 10 m/33 ft per minute · make your decompression stop deeper than at the ceiling These factors will also increase the amount of air required to reach the surface. NOTE WARNING Ceiling, ceiling zone, floor and decompression range When in decompression, it is important that you understand the meaning of ceiling, floor, and decompression range. · The ceiling is the shallowest depth to which you should ascend when in decompression. At this depth, or below, you must perform all stops · The ceiling zone is the optimum decompression stop zone. It is the zone between the minimum ceiling and 1. 2 m/4 ft below the minimum ceiling · The floor is the deepest depth at which the decompression stop time will not increase. [. . . ] A term used by Suunto for the values displayed in the oxygen toxicity bar graph. The value is either the CNS% or the OTU%. Oxygen percentage or oxygen fraction in the breathing gas. Limits the maximum depth to which the nitrox mixture can be safely used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO VYPER AIR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO VYPER AIR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag