User manual SYLVANIA QHE ISL CC DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SYLVANIA QHE ISL CC. We hope that this SYLVANIA QHE ISL CC user guide will be useful to you.

Lastmanuals help download the user guide SYLVANIA QHE ISL CC.


Mode d'emploi SYLVANIA QHE ISL CC
Download
Manual abstract: user guide SYLVANIA QHE ISL CCDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. sylvania. com QUICKTRONIC® T8 Instant Start Universal Voltage High Efficiency Series Lamp/Ballast Guide 32W T8 - OCTRON 1-lamp QHE1x32T8/UNV-ISL-SC-1 2-lamp QHE2x32T8/UNV-ISL-SC-1 3-lamp QHE3x32T8/UNV-ISL-SC-1 4-lamp QHE4x32T8/UNV-ISL-SC-1 ® Type CC Lamp Striation Control Low Ballast Factor Q HE ISL CC SYLVANIA QUICKTRONIC High Efficiency, (QHE) Type CC energy saving electronic T8 ballasts offer four major advantages: 1. [. . . ] 22 2-FO28/SS QHE2x32T8/UNV-ISL-SC-1 SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type Low Ballast Factor T8 Instant Start High Efficiency Performance Guide Data based upon SYLVANIA OCTRON® lamps shown. QUICKTRONIC® QHE Instant Start ballasts are also compatible with other manufacturers equivalent lamp types that meet ANSI specifications. QHE Instant Start ballasts will also operate F17, F25, F32 and the UBend equivalent & energy saving T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Electronic Ballast Catalog. High Efficiency Universal Voltage (120-277V) Type CC & Lamp Striation Control Item Number 49199 49395 OSRAM SYLVANIA Description QHE1x32T8/UNV ISL-SC-1 Banded Pack Pallet Pack Input Current (AMPS) 0. 21/0. 093 0. 21/0. 093 0. 20/0. 087 0. 18/0. 081 0. 16/0. 073 0. 40/0. 18 0. 40/0. 18 0. 38/0. 17 0. 35/0. 16 0. 31/0. 14 0. 60/0. 26 0. 60/0. 26 0. 56/0. 24 0. 53/0. 23 0. 47/0. 20 0. 81/0. 35 0. 81/0. 35 0. 76/0. 33 0. 71/0. 31 0. 63/0. 27 Lamp Type FO32/700 FO32XP FO30SS FO28SS FO25SS FO32/700 FO32XP FO30SS FO28SS FO25SS FO32/700 FO32XP FO30SS FO28SS FO25SS FO32/700 FO32XP FO30SS FO28SS FO25SS Rated Ballast Initial Mean Input System Lumens No. of Factor System System Power Efficacy (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF 1 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 0. 77 2155 2310 2195 2100 1905 4310 4620 4390 4195 3810 6470 6930 6585 6295 5715 8625 9240 8780 8395 7625 1940 2170 2065 1970 1790 3880 4345 4125 3945 3585 5820 6515 6190 5915 5375 7760 8685 8250 7890 7165 25 25 24 22 21 48 48 45 42 38 73 73 68 64 57 96 96 90 85 76 86 92 91 95 91 90 96 98 100 100 89 95 96 98 100 90 96 98 99 100 3. 08 3. 08 3. 21 3. 52 3. 67 1. 60 1. 60 1. 71 1. 83 2. 03 1. 05 1. 05 1. 13 1. 20 1. 35 0. 80 0. 80 0. 86 0. 91 1. 01 NEW! Q HE ISL CC QHE2x32T8/UNV ISL-SC-1 49200 49396 Banded Pack Pallet Pack QHE3x32T8/UNV ISL-SC-1 49367 49397 Banded Pack Pallet Pack Specifications Data based on F32T8 Starting Method: Instant Start Ballast Factor: 0. 77 Circuit Type: Parallel Lamp Frequency: >40kHz Lamp CCF: Less than 1. 7 Starting Temp: 2 -20°F (-29°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1 Outdoor UL Type CC Rated CSA Certified 70°C Max Case Temperature FCC 47 CFR Part 18 Non-Consumer Class A Sound Rating ANSI 62. 41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s · 4 ft: 25W energy saving T8s 2 Operation below 50°F (10°C) may affect light output or lamp operation ­ see "Low Temp. Starting" definition. QHE4x32T8/UNV ISL-SC-1 49368 49398 Banded Pack Pallet Pack Banded Pack contains 10 pieces, (add "-B" to Description). [. . . ] OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 23 QUICKTRONIC 4x32 Dimensions: Overall: 9. 5" L x 1. 68" W x 1. 18" H Mounting: 8. 90" Product Weight: 1. 6 lbs each (approx) Wiring: Leads only (no connectors provided) Height 8. 70 mm Slot Width Mounting Length Length Item Number QUICKTRONIC High Efficiency Number of Lamps Primary Lamp Wattage Specifications subject to change without notice. 49200 QHE 2 x 32T8 / UNV ISL - SC - 1 UL Type CC Case Size Starting/Ballast Factor Line Voltage (120-277V) [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA QHE ISL CC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA QHE ISL CC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag