User manual SYLVANIA QTP T8 ISL DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SYLVANIA QTP T8 ISL. We hope that this SYLVANIA QTP T8 ISL user guide will be useful to you.

Lastmanuals help download the user guide SYLVANIA QTP T8 ISL.


Mode d'emploi SYLVANIA QTP T8 ISL
Download
Manual abstract: user guide SYLVANIA QTP T8 ISLDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. sylvania. com QUICKTRONIC® T8 Instant Start Universal Voltage Low Ballast Factor Professional Series Lamp / Ballast Guide 32W T8 - OCTRON® 1-lamp QTP1x32T8 ISL-SC 2-lamp QTP2x32T8 ISL-SC 3-lamp QTP3x32T8 ISL-SC 4-lamp QTP4x32T8 ISL-SC Also operates: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS (30W), FBO30/SS (30W), FBO29/SS (29W), FO28/SS (28W) & FO25/SS (25W) FO40T8 operation: 1 lamp on 2L ballast, 2 lamps on 3L ballast, 3 lamps on 4L ballast SYLVANIA QUICKTRONIC SYSTEM 32 UNV ISL (LP) electronic T8 ballasts offer several advantages: 1. [. . . ] Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Electronic Ballast Catalog. Universal Voltage (120-277V) Item Number 49832 49741 49742 OSRAM SYLVANIA Description QTP1x32T8/UNV ISL-SC Banded Pack 10-Pack Pallet Pack Input Current (AMPS) 0. 22/0. 10 0. 22/0. 10 0. 22/0. 09 0. 21/0. 08 0. 17/0. 08 0. 44/0. 19 0. 44/0. 19 0. 41/0. 18 0. 38/0. 17 0. 34/0. 15 0. 65/0. 27 0. 65/0. 27 0. 60/0. 26 0. 57/0. 25 0. 50/0. 21 0. 80/0. 35 0. 80/0. 35 0. 78/0. 34 0. 73/0. 32 0. 63/0. 28 Lamp Type FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS Rated Ballast Input System Lumens No. of Factor System Mean Power Efficacy (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF 1 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 2185 2340 2220 2125 1930 4370 4680 4445 4250 3860 6550 7020 6670 6380 5790 8735 9360 8890 8500 7720 1965 2200 2090 2000 1815 3930 4400 4180 3995 3630 5895 6600 6270 5995 5445 7860 8800 8360 7990 7260 28/26 28/26 26/24 25/23 22/20 51 51 48 45 40 75 75 71 67 59 98 98 92 86 77 70/76 84/90 86/93 85/92 88/97 86 92 93 94 97 87 94 94 95 98 89 96 97 99 100 3. 00 3. 00 3. 25 3. 39 3. 90 1. 53 1. 53 1. 63 1. 73 1. 95 1. 04 1. 04 1. 10 1. 16 1. 32 0. 80 0. 80 0. 85 0. 91 1. 01 QTP2x32T8/UNV ISL-SC 49834 49743 49744 Banded Pack 10-Pack Pallet Pack Specifications Data based on F32T8 Starting Method: Instant Start Ballast Factor: 0. 78 Circuit Type: Parallel Lamp Frequency: >40kHz Lamp CCF: Less than 1. 7 Starting Temp:2 -20°F (-29°C) for OCTRON® T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1 Outdoor CSA Certified (where applicable) 70°C Max Case Temperature FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62. 41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s · 4 ft: 25W energy saving T8s 2 Operation below 50°F (10°C) may affect light output or lamp operation ­ see "Low Temp. Starting" definition. QTP3x32T8/UNV ISL-SC 49835 49745 49746 Banded Pack 10-Pack Pallet Pack QTP4x32T8/UNV ISL-SC 49836 49747 49748 Banded Pack 10-Pack Pallet Pack Q TP T8 ISL Banded Pack, (add "-B" to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add "-PAL" to Description). 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor X 100) divided by Input Power (Note: calculation based on lowest wattage value). Black White Red Blue Blue Black/White White Red Blue BALLAST BALLAST LAMP LAMP LAMP Note: For one lamp application, cap any blue lead. [. . . ] OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com QUICKTRONIC 4x32 Dimensions: Overall: 9. 5" L x 1. 68" W x 1. 18" H Mounting: 8. 90" Product Weight: 1. 6 lbs each (approx) Wiring: Leads only (no connectors provided) Height 8. 70 mm Slot Width Mounting Length Length Item Number QUICKTRONIC PROFESSIONAL Number of Lamps 49835 QTP 3 x 32T8 / UNV ISL - SC Case Size Starting/Ballast Factor Line Voltage (120-277V) Primary Lamp Wattage 27 Specifications subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA QTP T8 ISL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA QTP T8 ISL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag