User manual TAGHEUER CHRONOPRINTER 520

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TAGHEUER CHRONOPRINTER 520. We hope that this TAGHEUER CHRONOPRINTER 520 user guide will be useful to you.

Lastmanuals help download the user guide TAGHEUER CHRONOPRINTER 520.


Mode d'emploi TAGHEUER CHRONOPRINTER 520
Download
Manual abstract: user guide TAGHEUER CHRONOPRINTER 520

Detailed instructions for use are in the User's Guide.

[. . . ] PROFESSIONAL TIMING CHRONOPRINTER 520 OPERATING INSTRUCTIONS 1. KEYBOARD DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 2. BACK CONNECTIONS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3 3. START OF THE CP 520. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 3. 1 3. 2 3. 3 Batteries Installation ­ Batteries replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Its previous time is disidentified (­). Start times without bib N° Finish times without the bib N° To RECALL unidentified or disidentified start time(s) (memorized times) To RECALL unidentified or disidentified finish time(s) (memorized times) To RECALL a start time for a bib N° (for modification or cancellation) To RECALL a finish time for a bib N° (for modification or cancellation) Direct ranking You also find also these information at the back of your CP 520 ! + E2 R + E1 R + E2 N° + R + E1 N° + R + E2 F+# Page 8 4. NET TIME MODE (continued) 4. 4 Keyboard shortcuts explanation The bib N° expected at the start or at the finish is not correct: Enter the new N° and confirm with the key E1 (start) or E2 (finish) False starts or False Finishes ( false impulses or wrong N°'s, i. e. ): Disidentify the last bib N°(s) started with + E1 or finished by + E2 Recall unidentified start or finish time(s) (memorized times) with R + E1 (start) or R + E2 (finish) Identify all times with the related bib N°(s) The N° 0 cancels the considered time(s) The bib N°'s at the start or at the cannot be identified (mass finish for ex. ): Press for the start time(s) or for the finish time (s) The times are memorized and can be recalled for identification with R + E1 (starts) or with R + E2 (finishes) Modification of the bib N°'s already started or already finished: Recall the bib N° started or finished that you want to modify with N° + R + E1 (starts) or with N° + R + E2 (finishes) Follow the LCD indications The modified time of the competitor is disidentified (-) This time is then registered in the memorized time(s) Abort of a competitor (DNF): N° + R + 0 : Quick function to cancel the start time of a bib N° to be aborted (C) Disqualification of a competitor (DSQ): N° + R + 0 : Quick function to cancel the start and the finish time of a bib N° to be disqualified (C) IMPORTANT ! The CP 520 allows to accept the same bib number several times at the start and at the finish. The times taken into account in the ranking will be the last recorded times. At each start, the previous time will be disidentified (-), and at each finish, the previous time will be cancelled (C) Page 9 4. NET TIME MODE (continued) 4. 5 Rankings in the NET TIME mode In order to obtain the desired ranking of your race, you should well organize your different runs. Please consult point 5. 1 ­ REAL TIME ­ SEQUENTIAL. This mode is similar to the NET TIME mode. The difference is in the results calculation. Please consult the point 5. 2 ­ REAL TIME ­ START / FINISH. Before all, it is especially reserved for circuit races with lap times control of several competitors. Please consult the point 5. 3 ­ REAL TIME ­ LAP TIME. LAP TIME Each of the 3 REAL TIME modes offers several applications. Below, we give you an outline of the possibilities of each mode and its applications. 5. 1 SEQUENTIAL This mode proposes a synchronization at 00:00 or at time-of-day. According to the time of synchronization, various possibilities exist: Synchro at 00:00 It is possible to restart the device at zero or to stop and start again time only if the synchronization has been done at 00:00!Select START / STOP / RS in PARAMETERS ­ AUX. INPUT to be able to stop and restart the time again (jumping). Select RESET ACTIVE to be able to RESET the device at zero by pressing the key R. It is also possible to do an external RESET with the Input ST / SP / RS which can be programmed via the menu PARAMETERS (AUX INPUT-EXT. Synchro at the time-of-day Do the synchronization at the desired time-of-day. The SEQUENTIAL mode includes 3 different functions: SPLIT Start at zero and finishes (athletics, popular races, jumping, etc). If Reset to zero in pressing the key R (RESET ACTIVE) if wished. Timing at time-of-day for start and finish time registration (official timing sleeve when you work with a PC or make race protocols). SPLIT ­ LAP Start at zero or at time-of-day. [. . . ] Maximum consumption when a long ranking is required, be sure of the good state of the batteries. Page 19 Memorized information The CP 520 is equipped with a small accumulator in order to save memorized information even if you temporarily extract the batteries. It is recommended to leave batteries in the CP 520 if you wish to save information in memory. If the accumulator is partially or completely discharged, it is possible that the Chronoprinter does not work correctly any more, in this case, use the " RESET" function described below. To recharge a discharged accumulator, it is necessary to leave the CP 520 working during 14 hours with its internal batteries or external power supply. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TAGHEUER CHRONOPRINTER 520

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TAGHEUER CHRONOPRINTER 520 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag