User manual TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000 DATA SHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000. We hope that this TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000 user guide will be useful to you.

Lastmanuals help download the user guide TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000.


Mode d'emploi TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000
Download
Manual abstract: user guide TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000DATA SHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Digital Phosphor Oscilloscopes DPO7000 Series Data Sheet Event Search and Mark to Find Specific Events in the Entire Waveform Pinpoint® Triggering provides the Most Flexible and Highest Performance Triggering, with Over 1400 Combinations to Address Virtually Any Triggering Situation. 12. 1" XGA Display with Touch Screen Communications Mask Testing Clock Recovery from Serial Data Streams 64-bit NRZ Serial Pattern Trigger for Isolation of Pattern-dependent Effects up to 1. 25 Gb/s Low-speed Serial Protocol Triggering and Decode (I2C, SPI, RS-232, CAN, LIN, and FlexRay) Technology-specific Software Solutions provide Built-in Domain Expertise for MIPI® D-PHY, Ethernet, USB 2. 0 Compliance Testing, Jitter, Timing, Eye Diagram, Power, DDR Memory Bus Analysis, CAN, LIN, and FlexRay Network Design OpenChoice® Software with Microsoft Windows XP OS enables Built-in Networking and Extended Analysis Features & Benefits 3. 5 GHz Bandwidth Model for Serial and Digital Applications 2. 5 GHz, 1 GHz, and 500 MHz Bandwidth Models for All Applications Up to 40 GS/s Real-time Sample Rate on One Channel and up to 10 GS/s on All Four Channels Up to 500 Megasamples Record Length with MultiView ZoomTM Feature for Quick Navigation >250, 000 wfms/s Maximum Waveform Capture Rate Up to 310, 000 Waveforms per Second with FastFrameTM Segmented Memory Acquisition Mode User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy MyScope® Custom Windows and Right Mouse Click Menus for Exceptional Efficiency Applications Signal Integrity, Jitter, and Timing Analysis Verification, Debug, and Characterization of Sophisticated Designs Debugging and Compliance Testing of Serial Data Streams for Telecom and Datacom Industry Standards Low-speed Serial Bus Design (I2C, SPI, RS-232, CAN, LIN, and FlexRay) Investigation of Transient Phenomena Power Measurements and Analysis Spectral Analysis Data Sheet The family features exceptional performance in signal acquisition and analysis, operational simplicity, and unmatched debugging tools to accelerate your day-to-day tasks. The largest screen in the industry and the intuitive user interface provide easy access to the maximum amount of information. Unmatched Acquisition Performance Signal Fidelity of Tektronix Oscilloscopes Ensures Confidence in Your Measurement Results High sample rate on all models, on all channels, to capture more signal details (transients, imperfections, fast edges) 40 GS/s on one channel on the 2. 5 GHz and 3. 5 GHz models Option 2SR to double the maximum real-time sample rate for the 1 GHz model User-selectable bandwidth limiting choices. High bandwidth up to 3. 5 GHz, matched across 2, 3, or 4 channels and enabled by Tektronix proprietary DSP enhancement. The user-selectable DSP filter on each channel provides magnitude and phase correction plus extension to 3. 5 GHz for more accurate signal fidelity for complex measurements. [. . . ] By combining the signal analysis engine of the RSA6100A Real-Time Spectrum Analyzer with that of the industry's widest-bandwidth digital oscilloscopes, you can now evaluate complex signals up to 20 GHz without the need of an external down converter. You get the functionality of a vector signal analyzer, a spectrum analyzer, and the powerful trigger capabilities of a digital oscilloscope ­ all in a single package. Whether your design validation needs include wideband radar, high data-rate satellite links, or frequency-hopping communications, SignalVuTM vector signal analysis software can speed your time-to-insight by showing you time-variant behavior of these wideband signals. SignalVuTM enables detailed analysis in multiple domains. Floating Licenses Floating licenses offer an alternative method to manage your Tektronix asset. Floating licenses allow license-key enabled options to be easily moved among all your DPO/DSA70000B, MSO70000, and DPO7000 Tektronix oscilloscopes. Floating licenses are available for many license-key enabled options. To order a floating version of an option license add "DPOFL-" prefix to the option name. DPOFL-ET3) Check www. tek. com/products/oscilloscopes/floatinglicenses for additional information about floating license options. Characteristics Vertical System Characteristic DPO7054 DPO7104 DPO7254 DPO7354 Input Channels Bandwidth (DSP Bandwidth Enhance) Rise Time (DSP Bandwidth Enhance) Hardware Analog Bandwidth (­3 dB) Rise Time 10% to 90% (Typical) Rise Time 20% to 80% (Typical) DC Gain Accuracy Bandwidth Limits Input Coupling Input Impedance (Software selectable) Input Sensitivity Vertical Resolution Max Input Voltage, 1 M Max Input Voltage, 50 Position Range Offset Range 4 500 MHz 460 ps 500 MHz 460 ps 310 ps 1 GHz 300 ps 1 GHz 2. 5 GHz 160 ps 2. 5 GHz 3. 5 GHz*1 115 ps 2. 5 GHz Offset Accuracy Delay between any Two Channels (Typical) Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical) *1 3 GHz for sine wave of more than 4 div amplitude (typically). 300 ps 160 ps 145 ps 200 ps 100 ps 95 ps ±1% with offset/position set to 0 Depending on instrument model: 3. 0 GHz, 2. 5 GHz, 2 GHz, 1 GHz, 500 MHz, 250 MHz, and 20 MHz AC, DC, GND 1 M ±1% with 13 pF ±2 pF or 50 ±1% 1 M: 1 mV/div to 10 V/div 50 : 1 mV/div to 1 V/div 8 bit (>11 bit with Hi Res) ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz 5 VRMS, with peaks less than ±24 V ±5 divisions 1 mV/div to 50 mV/div: ±1 V 50. 5 mV/div to 99. 5 mV/div: ±(1. 5 V ­ 10 divisions) 100 mV/div to 500 mV/div: ±10 V 505 mV/div to 995 mV/div: ±(15 V ­ 10 divisions) 1 V/div to 5 V/div: ±100 V 5. 05 V/div to 10 V/div: ±(150 V ­ 10 divisions) 1 mV/div to 9. 95 mV/div: ±0. 2% (offset value-position) ±0. 1 div ±1. 5 mV 10 mV/div to 99. 5 mV/div: ±0. 35% (offset value-position) ±0. 1 div ±1. 5 mV 100 mV/div to 1 V/div: ±0. 35% (offset value-position) ±0. 1 div ±15 mV 1. 01 V/div to 10 V/div: ±0. 25% (offset value-position) ±0. 1 div ±150 mV 100 ps (50 , DC coupling and equal V/div at or above 10 mV/div) 100:1 at 100 MHz; 30:1 between 100 MHz and 2. 5 GHz > 20:1 between 2. 5 and 3. 5 GHz www. tektronix. com 11 Data Sheet Time Base System Characteristic DPO7054 DPO7104 DPO7254 / DPO7354 Time Base Range with Opt. 2SR Time Resolution (in ET/IT mode) with Opt. 2SR Time Base Delay Time Range Channel-to-Channel Deskew Delta Time Measurement Accuracy Trigger Jitter (RMS) Jitter Noise Floor Time Base Accuracy 50 ps/div to 1000 s/div -- 500 fs -- 50 ps/div to 1000 s/div 25 ps/div to 1000 s/div 500 fs 250 fs 5 ns to 250 s Range ±75 ns ((0. 06 / sample rate) + (2. 5 ppm × Reading)) RMS 1. 5 psRMS (typical) with enhanced triggering OFF <100 fsRMS with enhanced triggering ON <1 psRMS (<2 ps peak) for record duration <10 s (typical) <2. 5 psRMS for record duration <30 ms <65 parts/trillion for record durations <10 s ±2. 5 ppm + Aging <1 ppm per year 25 ps/div to 1000 s/div -- 250 fs -- Acquisition System Characteristic Real-time Sample Rates DPO7054 DPO7104 DPO7254 / DPO7354 1 Channel (Max) with Opt. 2SR Equivalent Time Sample Rate (Max) Maximum Record Length per Channel 20 GS/s -- 10 GS/s -- 5 GS/s -- 20 GS/s 40 GS/s 10 GS/s 20 GS/s 5 GS/s 10 GS/s 4 TS/s (for repetitive signals) 50 M (1-CH), 25 M (2-CH), 12. 5 M (4-CH) 125 M (1-CH), 50 M (2-CH), 25 M (4-CH) 250 M (1-CH), 125 M (2-CH), 50 M (4-CH) -- 40 GS/s -- 20 GS/s -- 10 GS/s -- Standard Configuration Record Length Opt. 10RL -- 500 M (1-CH) 250 M (2-CH) 125 M (4-CH) Maximum Duration at Highest Real-time Resolution (1-CH) Characteristic DPO7054 DPO7104 DPO7254 / DPO7354 Resolution with Opt. 2SR Max Duration with Standard Record Length and Sample Rate with Opt. 10RL 50 ps (20 GS/s) -- 2 ms -- 4 ms -- 10 ms -- -- 50 ps (20 GS/s) 25 ps (40 GS/s) 2 ms 1 ms 4 ms 2 ms 10 ms 5 ms -- 25 ps (40 GS/s) -- 1 ms -- 2 ms -- 5 ms -- 10 ms 12 www. tektronix. com Digital Phosphor Oscilloscopes -- DPO7000 Series Acquisition Modes Mode DPO7054 / DPO7104 / DPO7254 / DPO7354 Pinpoint® Trigger System Characteristic Sensitivity DPO7054 / DPO7104 / DPO7254 / DPO7354 FastAcq Acquisition Mode FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events Maximum FastAcq >250, 000 wfms/s on all 4 channels simultaneously Waveform Capture Rate Waveform Database Accumulate waveform database providing three-dimensional array of amplitude, time, and counts Acquire sampled values Sample Peak Detect Captures narrow glitches at all real-time sampling rates: 1/sample rate at 10 GS/s Averaging From 2 to 10, 000 waveforms included in average Envelope From 1 to 2×109 waveforms included in min-max envelope Hi-Res Real-time boxcar averaging reduces random noise and increases resolution FastFrameTM Acquisition Acquisition memory divided into segments; maximum trigger rate >310, 000 waveforms per second. Time of arrival recorded with each event. Frame finder tool helps to visually identify transients Roll Mode Scrolls sequential waveform points across the display in a right-to-left rolling motion. Up to 10 MS/s with a maximum record length of 40 M Internal DC Coupled External (Auxiliary Input) 1 M A Event and Delayed B Event Trigger Types Low-speed Serial Protocol Trigger Type (A event only) Main Trigger Modes Enhanced Triggering 0. 7 div DC to 50 MHz increasing to 1. 2 div at rated analog bandwidth (typical); 2. 5 div at 3. 5 GHz with DSP bandwidth enhance 250 mV from DC to 50 MHz increasing to 350 mV at 250 MHz (typical) Edge, Glitch, Runt, Width, Transition Time, Time-out, Pattern, State, Setup/Hold, Window ­ all except Edge, Pattern, and State can be Logic State qualified by up to two channels I2C, SPI, and RS-232 (standard). Trigger on address, data, and special handshaking states and other conditions Auto, Normal, and Single User-selectable; it corrects the difference in timing between the trigger path and the acquired data path (it supports all Pinpoint trigger types on both A and B events except pattern trigger and not available in FastAcq) Main, Delayed by Time, Delayed by Events, Reset by Time, Reset by State, Reset by Transition. All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Requires Opt. Support for AMI, HDB3, BnZS, CMI, MLT3, and NRZ encoded communications signals. Select among isolated positive or negative one, zero pulse form, or eye patterns as applicable to the standard On DPO7254 or DPO7354 only, and requires Opt. Up to 64 bit serial word recognizer, bits specified in binary (high, low, don't care) or hex format. Trigger on NRZ-encoded data up to 1. 25 Gb/s Triggers from negative sync composite video, field 1, or field 2 for interlaced systems, any field, specific line, or any line for interlaced or noninterlaced systems. [. . . ] C3) Calibration Data Report 5 Years (with Opt. C5) Repair Service 3 Years Repair Service 5 Years 20 MHz TekVPITM AC/DC 150 A current probe DC coupled current probe 500 MHz TekVPI high-voltage differential probe 1 GHz TekVPI high-voltage differential probe 1. 5 GHz TekVPI high-voltage differential probe 3. 5 GHz TekVPI high-voltage differential probe 3. 5 GHz TekVPI active single-ended probe 2. 5 GHz TekVPI active single-ended probe 1. 5 GHz TekVPI active single-ended probe >120 MHz TekVPI AC/DC 30 A current probe TekProbe-BNC Level 2 to TekVPI adapter 500 MHz, passive probe (four included with each model) 3 GHz, 20x low C probe 1 GHz differential probe 1 GHz active probe 1. 5 GHz active probe 1. 5 GHz differential probe 1 GHz high-voltage differential probe 3 GHz differential probe 400 MHz differential probe 1x passive probe 15 MHz Series current measurement systems High-voltage differential probes High-voltage probes *6 Probe requires TPA-BNC adapter. Cables Cable Description GPIB Cable (1 m) GPIB Cable (2 m) Centronics Cable Order 012-0991-01 Order 012-0991-00 Order 012-1214-xx Accessories Accessory Description Mini Keyboard (USB Order 119-7083-xx (fits in accessory pouch) interface) Keyboard (USB interface) Full-size keyboard with 4 port USB hub. Order 119-6633-00 Transit Case Order 016-1970-xx Rackmount Kit Order 016-1985-xx Front Hard-drive Option Order 016-1979-xx for Rackmount Kit Removable HD Spare Order 065-0744-xx Oscilloscope Cart Order K420 (requires 407-5192-xx bracket set) WSTRO WaveStarTM Windows application for remote access www. tektronix. com 17 Data Sheet Test Fixtures Fixture Description Instrument Upgrades Test fixture for use with Opt. USB Order 067-1686-xx 1000/100/10BASE-T Advanced Ethernet Test Package, includes test fixture, RJ-45 interconnect cable, and 1000BASE-T jitter test channel cable 1000/100/10BASE-T Basic Ethernet Test Package, includes test fixture and RJ-45 interconnect cable Advanced CAN and LIN triggering module To upgrade your DPO7000 Series oscilloscope, order DPO7UP with option as noted: Description Option To upgrade record length: TDSUSBF Probe Calibration/Power Deskew Fixture TF-GBE-ATP TF-GBE-BTP ATM-1 RL02 RL05 RL010*5 RL25 RL210*5 RL510*5 Adapters Adapter Description P6701B*6 P6703B*6 Optical/Electrical converter (Multi Mode) Optical/Electrical converter (Single Mode) From Standard Configuration to Opt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX DIGITAL PHOSPHOR OSCILLOSCOPES DPO7000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag