User manual TEKTRONIX MTH DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX MTH. We hope that this TEKTRONIX MTH user guide will be useful to you.

Lastmanuals help download the user guide TEKTRONIX MTH.


Mode d'emploi TEKTRONIX MTH
Download
Manual abstract: user guide TEKTRONIX MTHDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] The Limit Test Application Software (Option LT) makes it easier to validate how your signals are performing compared to a known good condition. The Mask Test Application Software (Options MTH and MTM) enables testing against a well-defined telecommunication or computer standard providing automated statistical analysis of signal quality. Option LT ­ Limit Test Application Software A common method for understanding your signal quality is to compare against a known good or "golden" waveform. You can apply horizontal and vertical tolerances to the golden waveform to create a template that can be used for quick, accurate Pass/Fail testing. [. . . ] Clock recovery allows you to perform more reliable and accurate mask testing. The oscilloscope can reduce setup time for making a mask test measurement by performing an Autoset for vertical, horizontal, and trigger parameters on the source signal. Additionally, to reduce the chance of failures, the oscilloscope can Autofit the waveform to the mask to minimize hits within the mask. It can do this a single time following an Autoset or it can perform an Autofit after every triggered acquisition. The Mask Test Application Software provides flexible test definitions enabling you to tailor the test to your needs. You can run a test for a user-defined number of waveforms (up to 2. 14×109). The Repeat Test and Pretest Delay capability enables swapping of test locations before proceeding with a test over multiple cycles of the test. You can set the number of violations that can occur before a test status is considered failed. The oscilloscope can also perform a number of actions when a test fails or completes. Actions the oscilloscope can perform when a test fails include stopping the acquisition, e-mailing a message indicating the test has failed, Detailed mask test results show statistical information for the test. The results include information on test sample size, failures, total number of hits, and the number of hits in each mask segment. saving a waveform to file, logging the date and time of the failure, printing a waveform, sending a GPIB SRQ, and sending a trigger out pulse. Actions the oscilloscope can perform when a test completes include sending a GPIB SRQ and sending a trigger out pulse. The Mask Test Application Software provides statistical results from each test conducted. The results include Pass/Fail status of the test, number of waveforms/samples tested, number of violations found, and the total number of hits within the mask. A secondary display shows the total number of hits in each segment of the mask providing further insight into any mask violations. www. tektronix. com 3 Data Sheet Characteristics Option LT ­ Limit Test Characteristics Characteristic Description Option MTH, MTM ­ Mask Test Characteristics Characteristic Description Test Source Template Storage Template Creation Margins Lock Template to Waveform Highlight Hits Limit Test Status Limit Test Control Reset Actions on Limit Test Failure Any Ch1 ­ Ch4, Math1 ­ Math4, R1 ­ R4 Limit test template can be saved into any R1 ­ R4 location or to a file Vertical tolerance from 0 to 5 divisions in 0. 1m (1/10, 000th) division increments Horizontal tolerance from 0 to 5 divisions in 0. 1m (1/10, 000th) division increments Note: Use Average acquisition mode to help create a smoother limit test template Lock ON: Template automatically re-scales with source channel settings changes Lock OFF: Template does not re-scale with source channel settings changes Highlight Hits ON: Visually highlight any samples that fall outside of the limit test template Highlight Hits OFF: Samples that fall outside of the limit test template are not visually highlighted Passed: No samples from the test source have fallen outside of the limit test template Failed: At least one sample from the test source has fallen outside of the limit test template ON: Limit test is active and hits are being tracked OFF: Limit test is not active and hits are not being tracked Clears all violations in preparation for another test Stop Acq: When Stop Acq is ON, the instrument stops acquiring if a limit test fails Beep*1: When Beep is ON, the instrument beeps if a limit test fails E-mail: When E-mail is ON, the instrument sends an e-mail if the limit test fails Save Waveform: When Save Wfm is ON, failed waveform data is saved to a file Log Date: When Log Date is ON, the date and time for each failed limit test is recorded to a file Print: When Print is ON, the instrument sends the waveform to a printer if a limit test fails SRQ: When SRQ is ON, the instrument sends a GPIB SRQ command if a limit test fails Test Source Mask Creation *1 Not available on MSO/DPO5000 Series. Any Ch1 ­ Ch4, M1 ­ M4, R1 ­ R4 Select standard mask from internal memory Load custom mask from text file with up to 16 mask segments Copy a standard mask to user mask and edit Included Standard Mask The standards available vary by model depending on the bandwidth and configuration of the instrument Types ITU-T DS0 Single (64 kb/s) DS0 Double (64 kb/s) DS0 Data Contra (64 kb/s) DS0 Timing (64 kb/s) DS1 Rate (1. 544 Mb/s) E1 Sym Pair (2. 048 Mb/s) E1 Coax Pair (2. 048 Mb/s) Clk Intf. Coax (2. 048 Mb/s) DS2 Rate Sym (6. 312 Mb/s) DS2 Rate Coax (6. 312 Mb/s) E2 (8. 448 Mb/s) 32Mb (32. 064 Mb/s) E3 (34. 368 Mb/s) DS3 Rate (44. 736 Mb/s) 97Mb (97. 728 Mb/s) E4 Binary 0 (139. 26 Mb/s) E4 Binary 1 (139. 26 Mb/s) STM1E Binary 0 (155. 52 Mb/s) STM1E Binary 1 (155. 52 Mb/s) STM-0 HDBx (51. 84 Mb/s) STM-0 CMI 0 (51. 84 Mb/s) STM-0 CMI 1 (51. 84 Mb/s) ANSI T1. 102 DS1 (1. 544 Mb/s) DS1A (2. 048 Mb/s) DS1C (3. 152 Mb/s) DS2 (6. 312 Mb/s) DS3 (44. 736 Mb/s) DS4NA (139. 26 Mb/s) DS4NA Max Output (139. 26 Mb/s) STS-1 Pulse (51. 84 Mb/s) STS-1 Eye (51. 84 Mb/s) STS-3 (155. 52 Mb/s) STS-3 Max Output (155. 52 Mb/s) SONET/SDH OC1/STM0 (51. 84 Mb/s) OC3/STM1 (155. 52 Mb/s) OC12/STM4 (622. 08 Mb/s) OC48/STM16 (2. 4883 Gb/s) OC48/STM16 FEC (2. 666 Gb/s) Ethernet 100BASE-TX STP (125 Mb/s) 100BASE-TX UTP (125 Mb/s) 1000B-SX/LX/PX (1. 25 Gb/s) 1000B-CX Norm, TP2 (1. 25 Gb/s) 1000B-CX Abs, TP2 (1. 25 Gb/s) 1000B-CX Abs, TP3 (1. 25 Gb/s) XAUI, Near (3. 125 Gb/s) XAUI, Far (3. 125 Gb/s) CPRI1228 (1. 228 Gb/s) CPRI (Common CPRI2457 (2. 457 Gb/s) Public Radio CPRI3072 (3. 072 Gb/s) Interface) USB 1. 1/2. 0 FS (12 Mb/s) HS:T1 (480 Mb/s) HS:T2 (480 Mb/s) HS:T3 (480 Mb/s) HS:T4 (480 Mb/s) HS:T5 (480 Mb/s) HS:T6 (480 Mb/s) 4 www. tektronix. com Limit and Mask Test Application Software -- Option LT, MTH, MTM Characteristic Description Characteristic Description Fibre Channel Fibre Channel Electrical OBSAI (Open Base Station Architecture Initiative) InfiniBand Serial ATA SAS FC133 Optical (132. 8 Mb/s) FC266 Optical (265. 62 Mb/s) FC531 Optical (531. 25 Mb/s) FC1063 Optical (1. 0625 Gb/s) FC1063 Optical Draft Rev 11 FC2125 Optical (2. 125 Gb/s) FC133E Elec. [. . . ] Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX MTH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX MTH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag