User manual TELEX AUDIOCOM SSA-424 REV C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TELEX AUDIOCOM SSA-424. We hope that this TELEX AUDIOCOM SSA-424 user guide will be useful to you.

Lastmanuals help download the user guide TELEX AUDIOCOM SSA-424.


Mode d'emploi TELEX AUDIOCOM SSA-424
Download
Manual abstract: user guide TELEX AUDIOCOM SSA-424REV C

Detailed instructions for use are in the User's Guide.

[. . . ] User Instructions SSA-424 Dual Digital Hybrid ADAMTM, ADAM CSTM, ZeusTM Intercom Systems LE V SE EL T -15 -12 SY -9 ST EM -6 -3 0 2 1 A PO WE R -10 dB 0dB +1 2d +4 B dB +8 4W dB RE LE F S VE EL L +3 +6 TW 1 +9 BA L O +1 4W 2 TO 2W LE V SE EL T T CH AN SE L 2 BA L -15 -12 SY -9 ST EM -6 -3 0 2 B -10 dB 0dB +1 2d +4 B dB +8 4W dB RE LEV F S EL EL +3 +6 TW 1 1 +9 BA L +1 4 2W TO 2W TO CH AN SE L 2 TM BA L SS A- 42 4 9350-7638-000 Rev C 10/04 PROPRIETARY NOTICE The RTS production information and design disclosed herein were originated by and are the property of Telex Communications, Inc. Telex reserves all patent, proprietary design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to others. COPYRIGHT NOTICE Copyright 2004 by Telex Communications, Inc. Reproduction in whole or in part without prior written permission from Telex is prohibited. [. . . ] Connect a separate Clear-Com party line to the J1B connector (System B). The SSA-424 features internal CD isolation. You can therefore connect the SSA-424 to powered Clear-Com cables, and it will not draw any power from the Clear-Com system. 2 On the SSA-424 front panel, set the System A and System B 2W CHAN SEL switches to position 2. If the System A or System B hybrid will not be used, set its 2W CHAN SEL switch to either OFF position. 1 Use the J1A connector on the back of the SSA424 to connect one 2-wire line to the System A hybrid. Use the J1B connector to connect a second 2-wire line to the System B hybrid. The pin configuration for the J1A and J1B connectors depends on whether you are connecting a balanced or unbalanced 2-wire line: Balanced Configuration Pin 1: Pin 2: Pin 3: No connection Balanced Audio + Input/Output Balanced Audio - Input/Output There are two possible configurations for unbalanced connection: Unbalanced Configuraton 1 Pin 1: Pin 2: Pin 3: Audio Common Audio + Input/Output No connection Unbalanced Configuration 2 Pin 1: Pin 2: Pin 3: Audio Common No connection Audio + Input/Output 2 On the SSA-424 front panel, set the CHAN SEL switches as follows: · Balanced Configuration: set the CHAN SEL switches to the BAL position · Unbalanced Configuration 1: set the CHAN · SEL switches to position 1. Unbalanced Configuration 2: set the CHAN SEL switches to position 2. If the System A or System B hybrid will not be used, set its 2W CHAN SEL switch to either OFF position. 10 SSA-424 USER MANUAL 2. 5 2. 5. 1 4-WIRE CALL SIGNAL CONNECTIONS These connections require the call signal option. Table 1. GPI Connector Pin-out (ADAM, ADAM CS, and Zeus) Pi n No . 1 2 3 4 5 6 7 8 9 10 Fu n c t i o n GPI Input #1 High (5-18 VDC) GPI Input #2 High (5-18 VDC) GPI Input #3 High (5-18 VDC) GPI Input #4 High (5-18 VDC) GPI Input #5 High (5-18 VDC) GPI Input #6 High (5-18 VDC) GPI Input #7 High (5-18 VDC) GPI Input #8 High (5-18 VDC) Common* Common* Common* Common* Common* GPI Out #1 GPI Out #2 GPI Out #3 GPI Out #4 GPI Out #5 GPI Out #6 GPI Out #7 GPI Out #8 Common* Common* Common* Common* CALL SIGNAL CONNECTIONS FOR ADAM, ADAM CS, AND ZEUS You can use the General Purpose Interface (GPI) connector to interface call signals. The pin-out of the connector is the same for all of these intercom systems (Table 1). ADAM GPI Connector: XCP-ADAM-MC, J11 ADAM CS GPI Connector: J903 Zeus GPI Connector: J27 If your intercom system is equipped with a UIO-256 Universal Input/Output Frame, you can also use that for connections (Tables 2 and 3, page 12). As an alternative to using the GPI, you can use external components to send and receive call signals as described in paragraph 2. 5. 2. Typical GPI connections are shown in Figure 5. Note, the example uses GPI outputs #1 and #2 and GPI input #1. You may substitute other GPI inputs and outputs. IMPORTANT NOTE FOR AZEDIT USERS: AZedit version 1. 06 includes a feature which allows you to invert the action of the GPI outputs. By default, these outputs are set to duplicate the actio of the RTS FR9528 Relay Frame accessory. This is the correct setting for use with the SSA-424. To check the AZedit setting, select Intercom Configuration in the Options menu. Click on the Options tab, then verify that Configure onboard GPI outputs in FR9528 mode is selected. TO SSA-424 AUX CONNECTOR (SYSTEM A OR B) 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 *Use any available common pin with any GPI input or output. DB9F CABLE CONNECTOR PIN NUMBERS (View from solder or crimp side) CLEAR-COM APPLICATION NOTE: IF A CALL ENABLE/INHIBIT SWITCH IS NOT USED, A JUMPER MUST BE INSTALLED TO ENABLE CALL SIGNALING. THE JUMPER IS NOT REQUIRED FOR ANY OTHER APPLICATION. 1 6 2 7 3 4 89 5 TO GPI IN COMMON TO GPI IN #1 (4-WIRE CALL RECEIVE INPUT) FROM GPI OUT #2 (OPTIONAL CALL ENABLE/INHIBIT CONTROL) FROM GPI OUT #1 (4-WIRE CALL SEND OUTPUT) GPI OUT COMMON (SEE UIO-256 APPLICATION NOTE) UIO-256 APPLICATION NOTE: GPI OUT - AT THE UIO-256 END, USE THE NORMAL OPEN (NO) CONTACT FOR GPI OUT CONNECTION, AND USE THE RELAY COMMON CONTACT FOR THE COMMON CONNECTION. [. . . ] Configuration 2, Switched Full Duplex Mode: Switches from half duplex to full duplex 3-9 seconds after conversation begins on the 4wire line. Stays in full duplex mode until 6090 seconds after conversation ceases. This helps to keep the line quiet during perdiods of no conversation, while permitting natural conversation when people are talking. This is the preferred operating mode for many situations, and par ticularly for fast, closecoordination, team operations. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TELEX AUDIOCOM SSA-424

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TELEX AUDIOCOM SSA-424 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag