User manual THERMADOR 08-04-351C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 08-04-351C. We hope that this THERMADOR 08-04-351C user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 08-04-351C.


Mode d'emploi THERMADOR 08-04-351C
Download
Manual abstract: user guide THERMADOR 08-04-351C

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions for Thermador Char Glo® Outdoor Barbecues Models: CGB30RCULP · CGB36RU CGB48RU · CGB48RSBU Installer: Owner: Please leave these instructions with the unit for the owner. Please retain these instructions for future reference. !L WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. AVERTISSEMENT: Si l'information dans ce manuel n'est pas suivie exactement, une incendie ou une explosion peut résulter, entrainant des dégats matériels, des blessures ou la mort. Inside Front Cover Contents SECTION 1: Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECTION 2: Gas Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Replace with the LP orifice supplied (marked 59). Slide the orifice out of the burner and remove. Replace with the LP orifice supplied (marked 73). On Model CGB48RSBU, convert the side burners for LP operation as follows: A. Remove the grate, burner caps, venturis and burner bases. Use a 7mm hex socket on a 3" ratchet extension and apply a piece of tape to the socket to hold the orifice in the socket while removing. Replace with the LP orifices supplied (number 115). Reassemble the burner bases and venturis. NOTE: Install the conversion sticker (supplied) beside the rating label. Page 8 SECTION 5: UNPACKING, MOVING AND PLACING THE UNIT TAPE 9. On all models, the bypass jet must be turned clockwise with a small flat-bladed screwdriver until fully seated to set proper low flow rate. Models CGB36RU, CGB48RU and CGB48RSBU are equipped with a pressure regulator that is permanently mounted within the cart. For use with propane, it must be converted. The regulator is located in the left storage compartment. Using a flat blade screwdriver, remove the cap on the top of the regulator and turn the cap over so that the letters LP are exposed. Make sure the spring in the regulator remains in position. See Figures 6 and 6A, below. Page 9 SECTION 5: UNPACKING, MOVING AND PLACING THE UNIT 11. If models CGB36RU, CGB48RU or CGB48RSBU will be used with an LP cylinder, follow these steps: A. Disconnect the existing flexible gas hose from the regulator and remove hose. The proper LP hose and regulator assembly must be provided. Accessory Model LPHose is available at your Thermador dealer. (Note: The permanently mounted regulator on the end of the manifold will still be used, but must be converted for LP operation per Step 10 on Page 9). This assembly can be purchased locally provided it meets the following specifications: Hose length to be 24". [. . . ] alternate gas, make sure the technician checks B. Make sure all controls are in the "OFF" position. for leaks at all points of connection in the control Turn on the gas supply to the unit. Use a spray panel area and at the infrared burner prior to bottle, brush or rag to apply the solution to all reassembly of the control panel and cover (Refer fittings and points of connection from the supply to NG to LP Conversion, LP to NG Conversion stub out up to and including the inlet to the instructions in Section 5). BURNER AIR ADJUSTMENT All burners are adjusted for proper flame characteristics at time of assembly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 08-04-351C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 08-04-351C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag