User manual THERMADOR 08-04-439D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 08-04-439D. We hope that this THERMADOR 08-04-439D user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 08-04-439D.


Mode d'emploi THERMADOR 08-04-439D
Download
Manual abstract: user guide THERMADOR 08-04-439D

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions for Thermador Char Glo® Outdoor Barbecues Models: CGBD30RX · CGBD36RX CGBD48RSBX · CGBD48RX CGBD30RX CGBD36RX CGBD48RSBX Installer: Owner: Please leave these instructions with the unit for the owner. Please retain these instructions for future reference. !L WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. AVERTISSEMENT: Si l'information dans ce manuel n'est pas suivie exactement, une incendie ou une explosion peut résulter, entrainant des dégats matériels, des blessures ou la mort. !L Inside Front Cover ­ Blank Contents SECTION 1: Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Clearance of 8" at the lower left rear of the unit must be maintained to allow adequate routing of the gas and electrical supply lines. In all installations, do not locate this outdoor cooking gas appliance under unprotected combustible overhead construction. II est interdit d'installer le present appareil au-dessous des surfaces combustibles non protegees. To non-combustible construction Above the cooking surface, a minimum 8" clearance from the sides is required to allow use of the rotisserie motor and skewer. A minimum of 3" clearance from the rear is required to allow proper opening of the hood. Cabinet access doors Cabinet access doors are available for the Thermador Drop-In barbecues. Model CAD30 is for use with barbecues CGBD30; Model CAD36 is for use with barbecues CGBD36, CGBD48SB or CGBD48R. Contact your Thermador dealer for additional information. Page 6 SECTION 4: ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS CAUTION CAUTION Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the National Electric Code ANSI/NFPA No. 70, current issue, or Canadian Electric Code C22. 1 Part 1. The Thermador® Char Glo® barbecues use an electronic ignition system that requires a 120 VAC, 15A, 60 Hz power supply. A properly grounded duplex outlet must be provided adjacent to the lower left rear corner of the unit. The conversion should be done by a qualified technician or your gas supplier. All orifices required for conversion are provided with the units. The following steps are necessary to convert for LP operation 1. Make sure that the unit is disconnected from the gas and electrical supplies. Unbolt the main burners from their attachment at the rear of the burner box and remove. Remove the knobs and control panel from the unit. From inside control panel area, locate the brass elbows that the orifices are attached to. Use a wrench on the flats of these elbows to keep them from turning during orifice removal and installation. Remove the main burner orifices and replace with the LP orifices supplied (marked 54). Orifice must extend a minimum of 1/8" into main burner air shutter with burner installed. Make sure burner will not disengage from orifice. 5. 7. From behind the unit, remove the louvered cover on the infrared rotis burner housing. [. . . ] Make sure all controls are in the "OFF" position. for leaks at all points of connection in the control Turn on the gas supply to the unit. Use a spray panel area and at the infrared burner prior to bottle, brush or rag to apply the solution to all reassembly of the control panel and cover (Refer fittings and points of connection from the supply to NG to LP Conversion, instructions in Section stub out up to and including the inlet to the 5). BURNER AIR ADJUSTMENT All burners are adjusted for proper flame characteristics at time of assembly. If the unit has been converted for use with alternate gas supply, some adjustment of the air shutter on the main burner may be necessary. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 08-04-439D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 08-04-439D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag