User manual THERMADOR 19-10-199M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 19-10-199M. We hope that this THERMADOR 19-10-199M user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 19-10-199M.


Mode d'emploi THERMADOR 19-10-199M
Download
Manual abstract: user guide THERMADOR 19-10-199M

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes & Standards, Including Fire-Rated Construction. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit's operation. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. [. . . ] For installation with the VR600 a Transition #1308-8 and an 8" round duct must be used. Before installing VCK-1 in hood or cabinet attach transition to top of VCK1 through holes with screws provided. IMPORTANT: Be sure the 8" x 13" knockout on the top of the housing body is removed before attaching the Transition. VCK1 with VCK300 (Integral Blower), VR600 or VR1000 (Remote Blower) these installations must meet all local code requirements. Unless otherwise required by compliance with local codes, recommended installation height from countertop to VCK1 mounting surface over counter level range, cooktop, 30" to 34", over indoor barbecue 34" to 48". Cut a 9-3/4" x 19" opening in the bottom of the cabinet or hood to allow for the ventilator body (see figures 2 and 3 for minimum clearance). Fig. 3 ¦ DUCTINGFORTHEVR600&VR1000 (Vertical Discharge only) ¦ 10" Diameter Duct for VR1000 8" Diameter Duct for VR600 (Duct NOT supplied) Transitions: For VR1000 - #1308-10 For VR600 - #1308-8 Transition Height 10-1/4" Minimum Clearance 1-3/8" Mounting Surface Recommended Depth 4-1/4" · ¦ ¦ 2. Fig. 4 ¦ 321 DUCTINGFORKITCHENCABINETINSTALLATION Fig. 5 Mounting Bolts are installed in rear position for Horzontial Discharge Mounting Bolts are installed in forward position Vertical Discharge ¦ 9-3/4" x 18-3/8" Cutout 3/4" required for Clearing Collar for Horizontal Discharge Front ¦ · ¦ Safety Warning: Turn off proper circuit at the service entrance and lockout panel before wiring this unit. VCK300 ONLY - Attach power supply leads (120 volts, 60 Hz. ) in accordance with the local codes through the end or top conduit knockout holes. Make electrical connections to wires inside of "J" box -- Black to black and white to white. Be sure junction box cover inside the unit is replaced properly. Connect green ground of unit to ground supply wire. 5. ¦ 10-1/2" ¦ Minimum Absolute 10-1/2" ¦ 321 321 321 321 321 321 321 321 321 321 321 321 321 321 21 3221 21 1 3221 1 21 21 21 21 21 21 21 21 21 21 21 VCK300 VR600&VR1000 Transitions: For VR1000 #1308-10 For VR600 #1308-8 VERTICAL Absolute Minimum HORZONTAL 4. VR600 and VR1000 ONLY - If VR600 or VR1000 is installed with VCK1 the plug or cap is to remain over receptacle. Secure VCK1 into position using four 3/4" long screws (provided), see figure 1 for mounting holes. Page 2 ¦ ¦ DUCTING FOR VR1000 & VR600 321 321 321 321 321 321 321 3214321 5 3214321 5 321 321 321 321 ¦ 321 321 321 321 321 321 321 321 321 321 321 321 321 321 321 21 21 21 21 21 21 212 1 3 2321 21 1 3 2121¦ 21 21 21 21 21 21 21 21 ¦ 21 21 21 21 ¦ 21 21 21 21 21 ¦ ¦ ¦ VERTICAL DISCHARGE *Damper Collar for 3-1/4" x 10" duct Minimum Clearance 1-3/8" Minimum 3" Length of 3-1/4" x 10" Minimum Clearance 3/4" *To Bottom of Damper Collar 1-1/4" } } ¦ ¦ HORIZONTAL DISCHARGE ¦ Recommended Depth 4-1/4" Minimum ¦ ¦ 21 21 21 21 ¦ 21 21 21 21 21 21 21 21 ¦ 3 2321 31 121 2121 32 321 321 321 321 321 321 321 6. 8. Tape all duct connections to assure an air tight system. Place chrome reflectors into position and secure with chrome flat head countersunk screw (provided). VCK300 ONLY - Install VCK300 power unit (packed separately) as shown in figure 5. [. . . ] Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 19-10-199M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 19-10-199M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag