User manual THERMADOR 19-11-930F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 19-11-930F. We hope that this THERMADOR 19-11-930F user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 19-11-930F.


Mode d'emploi THERMADOR 19-11-930F
Download
Manual abstract: user guide THERMADOR 19-11-930F

Detailed instructions for use are in the User's Guide.

[. . . ] Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. [. . . ] The break should be as close as possible to the location where the ducting enters the heated portion of the house. CABINET OR SOFFIT PREPARATION HOOD LENGTH Cabinet Front 30" 36" 42" 48" DIM. "A" 13-11/32" 15-1/2" 16" 17-1/2" 12" Bottom of Cabinet or Soffit Cabinet Vertical Discharge 12" 4-1/2" "A" 1/2" ¨ 8-1/2" 4" 1-7/8" 1-1/2"Dia. Holes 22" "B" 1/2" 4-1/2" "C" Rear Wall Hood Length Figure 1 TYPICAL INSTALLATION The hoods are designed for either vertical or horizontal discharge as shown in Figure A and B respectively. The recommended height from the countertop to the bottom of the hood is 30" to 36". These hoods are not recommended to be used over solid fuel fire barbecues. ¨ Figure 2 Hood Type H series HB series HT Height "B" 10" 10" 18" DIM. C 18" 13" 18" Optional Rear Discharge Note: It is important to select the ventilator to be used before cutting the duct opening on the cabinet or wall. PAGE 3 Round Duct Soffit Rough-in Plate Heat Lamp Transition Ventilator (VTN600Q) Filter Hood Back Splash (with Warming Shelf) Hood Heat Lamp Soffit Rough-in Plate Outside Wall Wall Cap Filter 30" to 36" 30" to 36" Back Splash (with Warming Shelf) Cooktop Cooktop Figure A ­ Vertical Discharge INSTALL THE ROUGH-IN PLATE: Note: Before installing the rough-in plate to the bottom of the cabinet or soffit, make sure that the cabinet or soffit is level. Detach the rough-in plate from the hood assembly by removing three shipping screws on the back and three shipping screws on the top of the hood assembly. Remove the proper knockout panels on the rough-in plate for the selected ventilator. The rough-in plate is reversible to allow either horizontal or vertical discharge for both knockout panels. Attach the rough-in plate to the cabinet or wall with the mounting screws (#10 x 1") provided. Use all holes provided in the rough-in plate. (Use wall anchors as necessary on drywalls. ) Figure B ­ Horizontal Discharge Longer Bracket (Provided with H/ HT Hoods) 7-1/2" 8" 12-3/4" Figure C H/HB/HT HOOD SERIES Hex Nut INSTALL THE INTEGRAL VENTILATOR MODEL VM410 (H and HT only): Note: For HB series hood the ventilator is shipped and pre mounted to the rough-in plate. For H/HT series hood the VM410 is to be purchased separately. Remove and discard the Z-shape bracket from the VM410. Remove the blower mounting bracket and replace with a longer bracket provided with the H/HT hood. Insert one end of the blower mounting bracket into the ventilator mounting channel located on the rough-in plate, and slip the other end over the weld stud on the rough-in plate. Secure assembly with the hex nut provided with the hood. D. PAGE 4 ¨ ¨ Transition Ventilator VM410 INSTALL THE INTEGRAL VENTILATOR MODEL VTN600Q: Insert one end of the blower mounting bracket into the ventilator mounting channel located in the rough-in plate, and slip other end of bracket into the weld stud on the rough-in plate and tighten it with the hex nut provided with the hood. D. INSTALL THE REMOTE VENTILATOR MODEL VR600, VTR600R OR VTR1000Q: For installing the remote ventilator on the roof or side wall, refer to the Installation Instructions provided with the ventilator. DUCTING CONNECTION: FOR INTEGRAL VENTILATOR MODEL VM410, 19-11-943 (HB Hoods): 1. Attach the transition (3-1/4" x 10") provided to the top of the rough-in plate, using the two shipping screws. Make sure the knockout on the rough-in plate is removed. Seal all joints between the rough-in plate and the transition with duct tape. [. . . ] Using the hex nuts provided secure the hood assembly to the rough-in plate. Install two halogen bulbs, size R20, 50 watts maximum. Also install two heat lamp bulbs, size R40, 250 watts maximum for H and HT Hood. Insert filter into the bottom rear slot of the hood assembly and fully compress the spring. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 19-11-930F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 19-11-930F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag