User manual THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN. We hope that this THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN user guide will be useful to you.

Lastmanuals help download the user guide THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN.


Mode d'emploi THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN
Download
Manual abstract: user guide THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN

Detailed instructions for use are in the User's Guide.

[. . . ] The duration of a single bit is equal to 1 / baud rate. Echo status: Specifies a "status level" to return to controlling device upon any operating change in Casablanca II. level 1 will return current mode, input, master level. [. . . ] As such there are tables for Status levels, Menus, Character Maps and other Parameters. Below are some examples of using the command format. These examples will show how and where to look up values. Example 1: To Take the Casablanca II out of standby: Header 254 236 Command 4 Argument 1 14 Argument 2 2 Argument 3 Ø -All entries from this command string were obtained from the Command List on page 5 of this document. Example 2: To select Input # 3: Header 254 236 Command 4 Argument 1 5 Argument 2 3 Argument 3 Ø -All entries from this command string were obtained from the Command List on page 5 of this document. Example 3: To change the front center level to +2, for the currently selected input: Header 254 236 Command 1 Argument 1 37 Argument 2 Ø Argument 3 2 -Command 1 is used because it is required to change a parameter that is not already listed under the "commands and argument 1's on the Command List. -Argument 1's value was found on the Input Variables chart, as indicated under the "Argument 1 description". -The Argument 2 was used because this is an Input variable. a parameter that is stored "by Input" -Argument 3's value is the "new value" that is desired for the parameter being edited. Example 4: To change the analog tape out source to the coax 3 input jack: Header 254 236 Command 1 Argument 1 3 Argument 2 1 Argument 3 9 -Command 1 is used because it is required to change a parameter that is not already listed under the "commands and argument 1's on the Command List. -Argument 1's value was found on the Global Variables chart, as indicated under the "Argument 1 description". -The Argument 2 was used because this is an Global variable. a parameter that is NOT stored "by Input" -Argument 3's value is the "new value" that is desired for the parameter being edited. In the case of Jack names/variable numbers, this data was found on the Jack Variable chart. 3 Rev 1. 1 2/2/04 Casablanca II Owners Manual Addendum RS232 Protocol and Control Details ­ Command List Command 1 1 3 Description Input Variable Change Global Variable Change Update Display Argument 1 Ø-255 Ø-255 1 2 3 4 Argument 1 Description Variable Number (see Input Variables chart) Variable Number (see Global Variables chart) Menu LEDs Menu Parameters Menu Display Re-display whole menu Argument 2 Argument 2 Desc Ø Input setting 1 Global setting Ø Ø Ø Ø Argument 3 Ø-255 Ø-255 Ø Ø Ø Ø Arg 3 Desc New value New value 4 Do Action 5 6 Select Input Mute 1-12 Ø 1 2 Ø -255 Ø -255 Ø 1-6 Ø 1 2 Ø Ø 1 2 3 4 5 8 9 1Ø 11 Ø 1 3 Input number. Matrix Special matrix Pro Logic Dolby Digital DTS Stereo Mono CS encoded CS non-encoded CS Cinema Input setting Global setting Internal setting Ø Ø Ø Ø Ø-255 Ø-255 8 9 12 14 Go To Menu Go To Menu W/Password Check Source change. Power main. time at new menu time at new menu 15 17 Power remote Mode select (Note: If in input select menu, this command should be followed by "03 04 00 00" to update the display. ) 2Ø 2Ø 2Ø Input Variable, Specified, Increment Global Variable Specified, Increment Internal Variable Specified, Increment Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø-255 From Input Variable Number Variable chart. Ø-255 From Global Variable Number Variable chart 9 Master Volume 4 Rev 1. 1 2/2/04 Casablanca II Owners Manual Addendum RS232 Protocol and Control Details ­ Command List Command Description Argument 1 Argument 1 Description 21 Internal Variable Specified, Decrement 21 21 26 36 Global Variable Specified, Decrement Internal Variable Specified, Decrement Variable, Input, Set Value Return To Previous Menu Argument 2 Argument 2 Desc Ø Input setting 1 3 Ø -255 Ø -4 Global setting Internal setting Argument 3 Arg 3 Desc Ø-255 From Input Variable variable chart. Number Ø-255 From Global Variable variable chart Number 9 Master Volume New Value Ø -255 Variable Number # of menus to go back 5 Get Input variable value Ø-255 Input Variable Number (see Input Variable Ø chart). Global Variable Number (see Global Variable 1 chart). Ø None Ø 1 Ø 2 Ø 3 Ø 4 Ø 5 Ø 6 Ø A/D Ø Mute Ø Mode Ø Tape Out Ø Setup Ø Balance Ø Display IR Ø Power Main Ø Up Ø Down Ø Power Remote Ø Status Ø Left Ø Right Ø Phase Ø Select Up Ø Select Down 5 Input setting Ø 5 6 11 Get Global variable value Ø-255 Return status Simulate Keypress Ø-4 Ø 1 2 3 4 5 6 7 8 9 1Ø 11 12 13 14 15 16 17 18 19 2Ø 21 22 23 Global setting Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Rev 1. 1 2/2/04 Casablanca II Owners Manual Addendum RS232 Protocol and Control Details ­ Command List Command Description Argument 1 24 25 26 Read Serial Number ** Ø See note #1 Read Configuration ** Ø See note #2 Return OS version ** See Ø note #3 Execute Macro ** See Ø note #4 1 2 Argument 1 Description EQ Power Standby Power Activate Argument 2 Argument 2 Desc Ø Ø Ø Ø Ø Ø Copy Current Input Settings Copy Current Speaker Settings Restore factory default settings 1-12 1-12 Ø 1 2 3 4 ** Note 1: ** Note 2: ** Note 3: ** Note 4: Input to copy to Argument 3 Ø Ø Ø Ø Ø Ø Ø Arg 3 Desc 12 15 17 25 Ø Input to copy to Ø To Current Input Ø To All Inputs Ø To Global Settings To Input and Jack Ø Names Ø To Everything After sending command Casablanca, Casablanca will return 6 ASCII bytes representing the serial number. [. . . ] 0 1 2 3 4 5 6 7 8 9 A B blank C Code (hex) 1F 6F Character D E F G H I J K L M N O P Q R S T U V W X Y Z Code (hex) 14 15 16 17 18 19 1A 1B 1C 1D 1E ØF ØD ØE 6C ØA ØB ØC 69 Ø 1 2 3 4 5 6 7 8 9 11 12 1Ø 13 Ø 2Ø 21 22 23 24 25 26 27 28 29 2A 19 Rev 1. 1 2/2/04 Casablanca II Owners Manual Addendum RS232 Protocol and Control Details ­ Jack Variables Jack Variables Jack Name Analog 1 Analog 2 Analog 3 Analog 4 Analog 5 Analog 6 Coax 1 Coax 2 Coax 3 Coax 4 Coax 5 Coax 6 Tos 1 Tos 2 Glass 1 Glass 2 AES 1 BNC 2 Tos 3 Glass 4 RF1 RF2 INPUT* OFF** Value 1 2 3 4 5 6 7 8 9 1Ø 11 12 13 14 15 16 17 18 19 2Ø 21 22 23 24 Video 1 Video 2 Video 3 Video 4 Video 5 Video 6 Video 7 Video 8 INPUT* OFF** In the Tape Out menu: 1 2 3 4 5 6 7 8 9 Ø *"INPUT" selection means that the tape out menu mirrors the source ctive on the main system as the user changes from one source to another **"OFF" means that there will be no source routed to the tape out jack. 20 Rev 1. 1 2/2/04 Casablanca II Owners Manual Addendum RS232 Protocol and Control Details The command to request a status level is 06 0x 00 00, where x= the status level. When this command is issued, there is a 6. 7mS delay before the first status byte is received. The ECHOS parameter in the Casablanca II determines what status levels of data are returned. The diagram below shows all 4 status levels returned and the delay times between them. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THETA DIGITAL CBII OS2 RS232 PROTOCOL OWN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag