User manual TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900. We hope that this TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900.


Mode d'emploi TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900
Download
Manual abstract: user guide TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900

Detailed instructions for use are in the User's Guide.

[. . . ] warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. [. . . ] The motor has been designed to run at this temperature and is Recognized by Underwriters Laboratories (UL), This normal operating temperature will not harm the motor provided the operation and maintenance instructions enclosed with each unit are followed. DB-2 REPLACEMENT PARTS LIST MOTOR KIT WHEEL KIT HOUSING KIT 950-7025 950-7010 950-7000 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com COPYRIGHT © 2000 TJERNLUND PRODUCTS, INC. B 09/00 These units have been factory tested and rated in accordance with AMCA standard 210, test code for air moving devices. Each DB-2 is electrically factory line tested before shipment. After opening carton, inspect thoroughly for hidden damage. If any damage is found, notify freight carrier and your distributor immediately and file a concealed damage claim. INSTALLATION (Tools Required) DRILL 5/16" DRILL BIT SCREW DRIVER 1/4" NUT RUNNER 1/4" WRENCH TIN SNIPS 1. Opening should be cut in the bottom or top of a horizontal duct or any side of a vertical duct. The motor shaft will then be in the horizontal position. Apply the mounting template provided to the duct, cut opening and drill four 5/16" holes noted on template. NOTE: If installing the DUCT BOOSTER® on a flat duct, the housing flanges will have to be bent at a 90 O angle before inserting DUCT BOOSTER® into duct. This will allow screws to better align with the speed clips provided. WIRING DUCT BOOSTER ® IN PARALLEL WITH HEAT CYCLE OR COOLING/BLOWER "ON" CYCLE 2. Attach speed clips to vent pipe and align with four holes drilled in step 1. 3. Insert DUCT BOOSTER® in the slot with the adjustable damper curved plate above blower wheel pointing in the direction of air flow. The front flange goes inside the duct and the side flanges go on the outside. Bend the flanges to conform to the duct. Secure DUCT BOOSTER® to duct utilizing speed clips and screws provided. Use wrench to tighten nut behind electrical box. INSTALLATION RESTRICTIONS Do not install the DUCT BOOSTER® where temperatures of air within the duct exceed 200 OF. This temperature would only rarely be found on a forced warm air system but could exist close to the furnace on a gravity warm air system. Locating the DUCT BOOSTER® near the outlet end of a duct will provide the most efficient performance. The DUCT BOOSTER® must be installed with the motor shaft horizontal. It can be installed on the bottom or top of a horizontal duct or any side of a vertical duct. Failure to install, maintain and/or operate the DUCT BOOSTER® in accordance with manufacturer's instructions may result in conditions which can produce bodily injury and property damage. Disconnect power supply when making wiring connections and servicing the DUCT BOOSTER®. Failure to do so may result in personal injury and/or equipment damage. [. . . ] The DUCT BOOSTER® SHOULD NOT BE WIRED IN PARALLEL WITH 240 VAC BLOWER MOTORS. The basic furnace wiring and components should not be disturbed except for wiring interconnection of the DUCT BOOSTER® and furnace blower motor at a splice box in the furnace. The rating of furnace blower motor controller must be adequate to control blower motor and the DUCT BOOSTER® motor. The DUCT BOOSTER® motor is rated 0. 5 amps. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND DB-2 DUCT BOOSTER 8504030 REV B 0900 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag