User manual TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805. We hope that this TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805.


Mode d'emploi TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805
Download
Manual abstract: user guide TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805

Detailed instructions for use are in the User's Guide.

[. . . ] IMPORTANT: Each millivolt appliance interlocked with the MAC4E must have its own Linear Limit spill switch. Multiple heaters firing at the same time will result in varying volumes of flue gas and varying vent system draft pressures. Make sure all heaters interlocked with the MAC4E operate within the normal draft range specified by the heater manufacturer. All heaters utilizing a fixed speed Venter/Inducer must be equipped with a draft hood, draft diverter, or barometric draft control. Tjernlund ABD-Series Balancing Baffles may be utilized for balancing draft on each heater. [. . . ] Do not let the opened Lead touch a ground or damage may occur to the control when power is reestablished. Reestablish power to the UC1 and interlocked appliances and initiate a call for heat. After 60 seconds a Prover Start Up fault should arise with UC1 LED #4 (RED) flashing 3 times. Remove appliance call for heat and power to the UC1 and any interlocked appliances. The Power LED (RED) on UC1 or any LED's on UC1 or MAC4E should not be on. Reconnect Fan Prover switch lead removed in step 4. Reestablish power to UC1 and interlocked appliances and initiate a call for heat from each appliance to confirm proper operation of UC1, MAC4E and appliances. Perform Draft Adjustment and Combustion air safety check as outlined in Venter/Inducer installation manual. IMPORTANT: DO NOT OPERATE AN APPLIANCE THAT OPERATES WITH THE PROVER SAFETY CIRCUIT DISCONNECTED!RESETTING FAULT CODE CREATED BY STEP 4 OF SAFETY INTERLOCK TEST IMPORTANT: Prior to accessing the fault code memory, note the settings of the UC1 dip switches so that they can be returned to their original Pre / Post-Purge positions. When power is supplied to the UC1 use caution when moving dip switches. The last fault code can be retrieved at any time by setting all dip switches 1-8 to the up, or "on" position. The last fault code, or lack there of, will be indicated by counting the number of times LED 4 flashes. By moving any of the dip switches back to their original position, the fault code will be cleared. NOTE: The UC1 board must have its 115 VAC power supply present when any of the (1-8) dip switches are moved back to their original position for the fault code to clear. Copyright © 2005, Tjernlund Products, Inc. All rights reserved. P/N 8504112 MAC4E WIRING CONNECTIONS WITH UC1 UNIVERSAL CONTROL Remove power to UC1 and heating equipment when making connections from the MAC4E to the UC1 or installing, servicing or changing dip switch settings in the UC1. Failure to do so may result in personal injury and/or equipment damage. The Power LED (RED) on UC1 or any LED's on UC1 or MAC4E should not be on. See UC1 Universal Control wiring section of Venter or UC1 instructions for 24 VAC, 115 VAC or Millivolt (Dry Contact) appliance interlock diagrams. The MAC4E and UC1 Universal Control appliance interlock steps and diagrams are identical. IMPORTANT: Venter Fan Prover must be wired to P1 & P2 safety circuit in UC1. Do not supply power to P1 & P2 or damage will result. The MAC4E contains four appliance interlock blocks which are identical. [. . . ] Connect Gray from second MAC4E whip to GND on MAC4E connected to UC1. 6. Connect Violet from second MAC4E whip to C2 on MAC4E connected to UC1. K2 K4 APPROVED SUPPLY 115 VAC 50/60 Hz INTERLOCK RELAY VENTER / INDUCER MOTOR 1 H. P. MAX @ 115 VAC K1 G R E E N INTERCEPTED CALL FOR HEAT INTERLOCK RELAY K1 GND F OPEN PROVER OPTION (9) K3 GND G R ARV YEI DO L E T G R E E N F K2 N MTR APPLIANCE 3 C R INTERLOCK RELAY V I O GL RE A RYT E D M TJERNLUND PRODUCTS, INC. W H I T E B L A C K DRY3 C24V C115V DRY4 D24V D115V APPLIANCE 4 BLUE LED8 UNIVERSAL CONTROL P/N 1303963B LED7 AMBER BLUE LED6 C2 LED5 AMBER MAC4E CONTROL CONNECTIONS FROM MAC4E TO UC1 UNIVERSAL CONTROL 1. Connect Black from MAC4E whip to XL on UC1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND MAC4E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 0805 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag