User manual TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199. We hope that this TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199.


Mode d'emploi TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199
Download
Manual abstract: user guide TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199

Detailed instructions for use are in the User's Guide.

[. . . ] A 11/99 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com T0890551100 MODEL SS1 INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important Safety Information! OWNER INSTRUCTIONS, DO NOT DESTROY NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 650o F AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] All diagrams in this section show the same electrical connections. Follow the diagram which is most appropriate for your installation. If your appliance gas valve is not labeled TH, TR as outlined in these diagrams, determine the "HOT" and "COM" terminals on the gas valve and follow the steps outlined on the bottom of Page 15. SIDESHOT FACTORY WIRING 14 SIDESHOT CONNECTED TO A 24V FURNACE OR BOILER WITH INTERMITTENT IGNITION LADDER DIAGRAM CONNECTION DIAGRAM SIDESHOT CONNECTED TO A 24V BOILER WITH A STANDING PILOT LADDER DIAGRAM CONNECTION DIAGRAM NOTES: The SideShot is always interlocked with the gas valve of the appliance. Wire all other furnace/boiler controls as normally done when conventional venting before continuing. Disconnect power from the appliance before attempting to interlock the SideShot. Remove the wire that is factory installed to the TH (HOT) terminal of the 24V gas valve. Connect the wire removed from the TH(HOT) terminal in step 1 to terminal O of the SideShot terminal strip. Connect terminal Y of the SideShot terminal strip to the TH (HOT) terminal of the 24V gas valve. Connect terminal R of the SideShot terminal strip to the TR(COM) terminal of the 24V gas valve. NOTE: Do not remove the factory installed wire from the TR(COM) terminal. Connect terminal L1 of the SideShot terminal strip to L1. Connect terminal L2 of the SideShot terminal strip to L2. Connect the Ground to grounding screw in SideShot electrical box. DRAFT ADJUSTMENT OIL The SideShot Vent system will properly vent a wide range of BTU/hr. To compensate for different burner capacities, vent connector lengths and wind conditions it features a draft adjustment located on the outside of the Vent Hood. In general, positioning the draft adjustment inward will cause the SideShot to operate at lowest capacity. Positioning the draft adjustment outward will cause the SideShot to operate at highest capacity. IMPORTANT: The following paragraph describes the initial draft adjustment. It may be necessary to make a slight readjustment to compensate for various conditions: wind, vent connector resistance, negative building pressure and multiple appliances. ASHRAE lists the average design factor for wind loads in North America at 15 MPH. Refer to the Draft Adjustment Chart on Page 17. We recommend that the 25 MPH category be used to allow for excursions beyond the 15 MPH average. [. . . ] If the part is over 30 months old, proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under two years. All receipts should include the date code of the SideShot to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 1. ) Follow troubleshooting guide to determine defective component. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag